Cylindrical fuse-links
14Pages

{{requestButtons}}

Catalog excerpts

Cylindrical fuse-links - 3

AL DRIC LINS CY FUSE E PAG LF DRICA FUSES CYLININDRICAL | gG L 02 | aM CY 04

Open the catalog to page 3
Cylindrical fuse-links - 4

CYLINDRICAL FUSES FUSES gG CYLINDRICAL class for use as general protection against overloads and short circuits, intended as protection of Cylindrical fuse links gG cables, power lines and equipment. Made of ceramic tube with high withstand to internal pressure and thermal shock, that allow a high breaking capacity in a reduced physical space. The melting elements are specially designed in order to avoid aging and thus maintain unalterable the electrical characteristics. Contact caps are made of silver plated copper. Versions available with fusing indicator or with striker for use in fuse...

Open the catalog to page 4
Cylindrical fuse-links - 5

CYLINDRICAL FUSES BREAKING CAPACITY BREAKING CAPACITY WITHOUT INDICATOR REFERENCE WITH INDICATOR WITH STRIKER * Overrating fuses PACKING Uni./BOX gG CYLINDRICAL FUSES DIMENSIONS TECHNICAL

Open the catalog to page 5
Cylindrical fuse-links - 6

CYLINDRICAL FUSES FUSES aM CYLINDRICAL class are intended for short circuit protection in motors, transformer and other load with high inrush Cylindrical fuse links aM currents. Excellent protection of switchgear (contactor, thermal switch) due to the good current limiting capability and low I2t values. These fuse links must be associated to an overload device protection as a thermal switch. Made of ceramic tube with high withstand to internal pressure and thermal shock, that allow a high breaking capacity in a reduced physical space. The melting elements are silver plated in order to avoid...

Open the catalog to page 6
Cylindrical fuse-links - 7

CYLINDRICAL FUSES BREAKING CAPACITY BREAKING CAPACITY WITHOUT INDICATOR REFERENCE WITH INDICATOR WITH STRIKER * Overrating fuses PACKING Uni./BOX aM CYLINDRICAL FUSES DIMENSIONS TECHNICAL

Open the catalog to page 7
Cylindrical fuse-links - 8

CYLINDRICAL FUSES gG CYLINDRICAL FUSES t-I CHARACTERISTICS gG CYLINDRICAL FUSES CUT-OFF CHARACTERISTICS TECHNICAL Maximum value of current (kA peak) Asymmetrical short-circuit

Open the catalog to page 8
Cylindrical fuse-links - 9

CYLINDRICAL FUSES CYLINDRICAL FUSES POWER DISSIPATION

Open the catalog to page 9
Cylindrical fuse-links - 10

CYLINDRICAL FUSES aM CYLINDRICAL FUSES t-I CHARACTERISTICS aM CYLINDRICAL FUSES CUT-OFF CHARACTERISTICS TECHNICAL Maximum value of current (kA peak) Asymmetrical short-circuit

Open the catalog to page 10
Cylindrical fuse-links - 11

CYLINDRICAL FUSES aM CYLINDRICAL FUSES I2t CHARACTERISTICS TECHNICAL aM CYLINDRICAL FUSES POWER DISSIPATION TECHNICAL

Open the catalog to page 11
Cylindrical fuse-links - 12

CYLINDRICAL FUSES gG CYLINDRICAL FUSES DC APLICATIONS TECHNICAL Fuses are generally suitable for both AC and DC applications. The DC performance of fuse-links is different and AC ratings cannot be used for DC applications. There is no simple rule that safely converts an AC voltage rating of a fuse-link to DC voltage rating. For this reason it is necessary to take into account a lot of aspects in order to determine the DC applications. In the DF ELECTRIC gG cylindrical fuses it is necessary to take into account the following considerations: • The power dissipations are the same in AC (RMS...

Open the catalog to page 12
Cylindrical fuse-links - 14

HEAD OFFICE & FACTORY EXPORT SALES NATIONAL SALES