Modules with CAN or RS-485 interface | EPAD2 | CPAD2 | CPAD3
16Pages

{{requestButtons}}

Catalog excerpts

Modules with CAN or RS-485 interface | EPAD2 | CPAD2 | CPAD3 - 1

EPAD & CPAD Modules precision measurement of slow signals in rough environments, e.g. in an engine bay of a vehicle Key Features Extremely rugged Up to 24 bit A/D converter per channel Channel to channel isolation Channel to system isolation Flexible connectivity Flexible mounting High channel count by daisy-chaining distributed monitoring of slow signals in industrial plants high quality logging of environmental conditions quasi-static channel expansion of dynamic DEWETRON instruments EPAD2 and CPAD2/CPAD3 series modules can be daisy-chained to achieve a high channel count even over very long distances. Data output of CPAD2/CPAD3 series is available on CAN bus while EPAD2 series has a RS485 interface. For EPAD2 series there is an interface module (EPAD2-USB) available, which connects EPAD2 modules to a USB interface. Signal Conditioning The EPAD2 and CPAD2/CPAD3 series are multichannel modules and combine analog signal conditioning and A/D converter in an extremely rugged box. EPAD2/CPAD2 support 24 bit whilst CPAD3 modules support 20 bit A/D converter per channel, synchronized sampling, channel to channel and channel to system isolation. The sampling rate is 12 samples for EPAD2/CPAD2 modules and 100 samples per second for CPAD3 modules. The target applications are Modules with CAN or RS-485 Interface Dedicated Instruments Automotive Energy & Power Analysis Aerospace & Defense Tr a n s p o r t a t i o n G e n e r a l Te s t & M e a s u r e m e n t

Open the catalog to page 1
Modules with CAN or RS-485 interface | EPAD2 | CPAD2 | CPAD3 - 2

EPAD & CPAD Modules Mounting Examples The EPAD2 and CPAD2/CPAD3 series modules are extremely rugged and offer a wide range of mounting options. DIN rail By ordering option XPAD-DIN-RAIL an adapter to snap EPAD2 and CPAD2/CPAD3 modules onto a DIN rail is included. A typical application for this is using EPAD2/CPAD2/CPAD3 inside 19” cabinets. Cable strap All modules have four trenches to provide maximum flexibility, most popular is fixing the modules by means of cable straps. A typical application for this is installing modules inside an engine bay of a vehicle. Bolt down All modules offer...

Open the catalog to page 2
Modules with CAN or RS-485 interface | EPAD2 | CPAD2 | CPAD3 - 3

Channel to channel isolation Channel to system isolation CAN interface Flexible mounting High channel count by daisy-chaining Input ranges Overvoltage protection Dedicated modules for type J, K, T Universal module for types K, J, T, E, R, S, B, N, C, U According thermocouple type 1500 VDC (channel to channel and channel to BUS, power and chassis) 8 isolated voltage input channels Physical input range: ±50 V Software selectable: ±100 mV, ±500 mV, ±1 V, ±2.5 V, ±5 V, ±10 V 1500 VDC (channel to channel and channel to BUS, power and chassis) EPAD-ADAP-BL: Binder 712-series to LEMO 1B.304...

Open the catalog to page 3
Modules with CAN or RS-485 interface | EPAD2 | CPAD2 | CPAD3 - 4

CPAD3-TH8-x Intelligent amplifier with integrated A/D conversion CAN interface 8 input channels for thermocouples Available thermocouple types: CPAD3-TH8-x: K, J, T standard type CPAD3-TH8-UNIVERSAL: Universal type Specifications Input channels Input signals CPAD3-TH8-x CPAD3-TH8-UNIVERSAL Sampling rate Bandwidth (-3 dB) ADC type Input connector Resolution Input impedance Bias current Open thermocouple detection Accuracy Standard models CPAD3-TH8-K /-J / -T Type K (-270 to 1372 °C): Type J (-210 to 1200 °C): Type T (-270 to 400 °C): Special models on request CPAD3-TH8-x Type R, S (-50 to...

Open the catalog to page 4
Modules with CAN or RS-485 interface | EPAD2 | CPAD2 | CPAD3 - 5

Input channels Input ranges Resolution DC accuracy Temperature drift Linearity Input impedance Input connector Sampling rate Bandwidth (-3 dB) ADC Type Isolation voltage Overvoltage protection CMRR (50/60 Hz) @ 0.01 to 10 S/sec CPAD3-V8 Interface Specication Communication speed Data format Identier types Standard settings Readout speed highspeed CAN CAN 2.0B 50 kBaud to 1000 kBaud 16 Bit Intel or Motorola standard; extended 500 kBaud; Intel Format 100 Hz, 50 Hz, 20 Hz, 10 Hz, 5 Hz, 2 Hz, 1 Hz, 0.5 Hz, 0.2 Hz or 0.1 Hz, 0.05 Hz, 0.02 Hz, 0.01 Hz, programmable LEMO EGG.1B.304 7 to 40V 1W 129...

Open the catalog to page 5
Modules with CAN or RS-485 interface | EPAD2 | CPAD2 | CPAD3 - 6

■ Channel to channel isolation m Channel to system isolation m High channel count by daisy-chaining Options & accessories Connecting cable with connector on both sides Adapter cable to connect nect CPAD modules to 2 banana plugs for power EPAD-ADAP-BL: xPAD-TERM-L Binder 712-series to LEMO Termination connector for 1B.304 converter the last module in a chain

Open the catalog to page 6
Modules with CAN or RS-485 interface | EPAD2 | CPAD2 | CPAD3 - 7

EPAD2/CPAD2-TH8-x 8 input channels for thermocouples Available thermocouple types: xPAD2-TH8-x: K, J, T standard type xPAD2-TH8-UNIVERSAL: Universal type CPAD2-TH8-x: CAN interface EPAD2-TH8-x: RS485 interface (optional USB, RS232, CAN via EPAD-BASE2 interface) Temperature drift Isolation voltage Overvoltage protection CMRR (50/60 Hz) EPAD2-TH8 Interface Communication speed Standard settings Readout speed CPAD2-TH8 Interface Specication Communication speed Data Format Identier Types Standard settings Readout speed Bus/Power Connector Power Supply Voltage Power consumption Dimensions Base...

Open the catalog to page 7
Modules with CAN or RS-485 interface | EPAD2 | CPAD2 | CPAD3 - 8

EPAD2/CPAD2-V8 Intelligent amplifier with integrated 24-bit A/D conversion 8 isolated voltage input channels RS-485 or CAN interface CPAD2-V8: CAN interface EPAD2-V8: RS485 interface (optional USB, RS232, CAN via EPAD-BASE2 interface) Specifications Input channels Input ranges Resolution DC accuracy Temperature drift Linearity Input impedance Input connector Sampling rate Bandwidth (-3 dB) ADC Type Isolation voltage Overvoltage protection Common mode voltage CMRR (50/60 Hz) EPAD2-V8 Interface Communication speed Standard settings Readout speed CPAD2-V8 Interface Specication Communication...

Open the catalog to page 8
Modules with CAN or RS-485 interface | EPAD2 | CPAD2 | CPAD3 - 9

Specifications Input channels Input ranges Accuracy Resistance accuracy Sampling rate Bandwidth (-3 dB) ADC type Input connector Connection type Noise Resolution Constant current Input impedance Bias current Sensor fault detection Temperature drift Isolation voltage Overvoltage protection CMRR (50/60 Hz) EPAD2-RTD8 Interface Communication speed Standard settings Readout speed CPAD2-RTD8 Interface Specication Communication speed Data format Identier types Standard settings Readout speed Bus/Power Connector Power Supply Voltage Power consumption Dimensions Base module (W x D x H) Mounting...