DEWE2 Modular Data Acquisition Systems
40Pages

{{requestButtons}}

Catalog excerpts

DEWE2 Modular Data Acquisition Systems - 1

Signal Conditioning Dedicated Instruments Modular Data Acquisition Systems DEWE2 Series Modules

Open the catalog to page 1
DEWE2 Modular Data Acquisition Systems - 2

System Architecture High spee d data inter face Data Acquisition Module Flexible connectorpanel Signal conditioning High speed data transfer and synchronization User exchangeable TRION™ modules Binary / counter / timer modules Bus interface modules Analog signal conditioning modules Timing / sync modules

Open the catalog to page 2
DEWE2 Modular Data Acquisition Systems - 3

Powerful online or offline data processing Attractive online displays Full hardware control Fast data analysis Post processing and/or export to many file formats Simple reports Wide range of housings Signal Conditioning Dedicated Instruments

Open the catalog to page 3
DEWE2 Modular Data Acquisition Systems - 4

A-series All-in-one instruments Most compact, includes powerful i7 computer, brilliant display and keyboard, touchpad. Most convenient for all mobile applications like inspecting facilities, rotating machines, test stands, power generators, electrical machines, buildings, vehicles, aircrafts, trains, and anything else. M-series Mainframes Like the A-series but without display; keyboard and pointing device are included loose. Very popular for applications where the instrument is installed in a poorly visible place for the user (e.g. in a car the instrument is often installed in the leg area...

Open the catalog to page 4
DEWE2 Modular Data Acquisition Systems - 5

Analog signals like acceleration, temperature, strain, pressure, force, voltage, etc. Digital signals like static, counters, encoders Bus systems like CAN-bus, FlexRay™, XCP GPS Video cameras (hardware synchronized) Video Sensor system Major sensor systems like Kistler RoaDyn ® 2000 wheel force transducers or GeneSys ADMA INS/GPS system Your advantage: SYNC-CLOCK™ enables reduction of editing and analysis times by up to 50 %. At the same time, the quality of the analysis results can be improved by a factor of 5 – 10. User exchangeable modules DEWETRON INSTRUMENT SYNC Dedicated Instruments...

Open the catalog to page 5
DEWE2 Modular Data Acquisition Systems - 6

High channel density The basic consideration for DEWE2 chassis is a height of 4 U (~177 mm or ~7 in.) TRION™ modules are made for optimal utilization of that space The size of input connectors limits the channel count per module A single 4 U chassis can hold up to 144 analog inputs 4U 5U Systems are scalable from six to thousands of channels Your advantage: The small size and the low weight of portable systems enable simple and cheap transportation In high channel-count applications more than 1000 channels can be fitted into a single 19” cabinet Self test and calibration port Most TRION™...

Open the catalog to page 6
DEWE2 Modular Data Acquisition Systems - 7

DEWE2 Advantages Demand for greater accuracy? Voltage drops disturb your measurement? TRION™ series modules easily take it on with all similar products on the market Supply voltage drops up to 10 minutes are bridged by an internal buffer battery typical voltage curve when you start a car Have had enough of ground loops? Need more battery time? Isolated power supply Fully battery powered Maximum safety Hot-swappable batteries for continuous operation without an external power source for hours. Removable hard disk / SSD We protect your critical data by using reliable, industrial solid state...

Open the catalog to page 7
DEWE2 Modular Data Acquisition Systems - 8

SYNC it all! To create high channel count systems or for distributed measurements DEWE2 instruments support multiple synchronization options. A special feature is the perfectly hardware synchronized video acquisition since also for data analysis the slogan ”a picture is worth a thousand words” is true. Synchronization of multiple DEWE2 systems via Sync-cable Sync via TRION™ modules To use TRION-BASE or TRION-TIMING modules for synchronization of multiple units is the most convenient and easiest way. Two instruments synchronized via TRION-BASE modules (multiple units possible) DEWE2-A4 with...

Open the catalog to page 8
DEWE2 Modular Data Acquisition Systems - 9

IRIG Two instruments synchronized to absolute IRIG time IRIG SOURCE Dedicated Instruments There are 2 ways how to synchronize DEWE2 instruments very accurately to absolute time. Both, GPS time and IRIG time, enable execution of synchronized distributed measurements over unlimited distances. Each instrument (or array of instruments) must be connected to the time-code via a TRION-TIMING module. Synchronization to GPS or IRIG time-code VIDEO-SYNC Hardware synchronized video of up to 200 frames per second (camera clocked by DEWE2 instrument): accurate per sample, no delay Software synchronized...

Open the catalog to page 9
DEWE2 Modular Data Acquisition Systems - 10

Removable Solid State Disk Hard disk Hard disk 11 to 32 VDC (10 to 36 VDC) isolated incl. external AC power supply Add internal buffer battery for ~ 10 min. operation and/or DW2-UPS-150-DC (ext. battery pack) Battery powered, 3 battery slots , 3 batt. for ~2 hours operation included, incl. external AC power supply,optional external DC power supply Battery powered, 3 battery slots 3), 3 batt. for ~2 hours operation included, incl. external AC power supply,optional external DC power supply 0 to +50 °C, down to -20 °C with prewarmed unit 0 to +50 °C, down to -20 °C with prewarmed unit 0 to +50...

Open the catalog to page 10
DEWE2 Modular Data Acquisition Systems - 11

Main system Main frame bandwidth Upstream interface (to host) Downstream interface Express card 34, 1 m cable (optional 3 m or 7 m) optional PCI Express X1 card Host PC interface Power supply standard: rated (max.) Optional power supply: rated (max.) 11 to 32 VDC (10 to 36 VDC) isolated, optional with buffer battery for ~ 10 min. 11 to 32 VDC (10 to 36 VDC) isolated, optional with buffer battery for ~ 10 min. Redundant AC power supply Redundant AC power supply 0 to +50 °C, down to -20 °C with prewarmed unit 0 to +50 °C, down to -20 °C with prewarmed unit 0 to +50 °C, down to -20 °C with...

Open the catalog to page 11
DEWE2 Modular Data Acquisition Systems - 12

DEWE2-M4 Slots for TRION™ acquisition modules Quasi-static channel expansion Dynamic channel expansion Data storage 1) Technology Removable Solid State Disk Solid State Disk 11 to 32 VDC (10 to 36 VDC) isolated; incl. external AC power supply 11 to 32 VDC (10 to 36 VDC) isolated; incl. external AC power supply add internal buffer battery for ~ 10 min. operation and/or DW2-UPS-150-DC (ext. battery pack) add internal buffer battery for ~ 10 min. operation 0 to +50 °C, down to -20 °C with prewarmed unit 0 to +50 °C, down to -20 °C with prewarmed unit Capacity Typ. duration of recording (16 ch....

Open the catalog to page 12

All DEWETRON GmbH catalogs and technical brochures

  1. CVT Logger

    1 Pages

  2. DEWE-2600

    3 Pages

  3. DEWE2

    46 Pages

Archived catalogs

  1. DEWE-CLOCK

    2 Pages

  2. TRION Series

    18 Pages

  3. DEWE-501

    4 Pages

  4. Mainframes

    16 Pages