Current Transducers with high precision
4Pages

{{requestButtons}}

Catalog excerpts

Current Transducers with high precision - 1

Current Transducers High Precision Current Transducers 3 to 6 channels Models from 200 A pk to 1000 A pk High linearity Low offset Dedicated Instruments High bandwidth Low phase error Power supply PM-MCTS Overload Ability Normal Operation Temperature Influence Frequency Influence Phase error General Bandwidth Output Ratio Shunt Amplitude-error depending on range (DC) 10000 Nominal Current Range Basic Three Channel System Additional Current Channel Optional Shunt Optional Shunts Amplitude-/ phase-error depending on frequency 100000 Signal Conditioning 700-U can be directly supplied from measurement device for mobile solutions - MCTS Rack - Power Cord Angular Accuracy Frequency Range Amplitude Accuracy - 1 internal Power Supply Model Transducer - 3 internal Power Supplies - 1 Transducer Head - 1 Connection Cable

Open the catalog to page 1
Current Transducers with high precision - 2

Current Transducers Current Output Voltage Output PM-CTS-2000IHF Primary Nominal current (Ipn) Programmable in steps of Polarity Nom. output range Primary current range DC, RMS sinus Peak Overload ability - short time (100 mS) Phase error Cable length Standard Optional Overload capacity (fault) Bandwidth Temperature influence Output ratio Frequency influence Electronics Dimension Weight Transducer heads Dimension Weight Rack mount 482 x 88 x 381 mm (19 x 3.5 x 15 in.) 9 kg (19.8 lb.) With ø50 hole 165 x 200 x 50 mm (6.5 x 7.9 x 2 in.) 3.3 kg (7.28 lb.) Rack mount 482 x 88 x 381 mm (19 x 3.5...

Open the catalog to page 2
Current Transducers with high precision - 3

Current Measurement Sensors Working temperature Connector type Output % accuracy Working temperature Connector type Phase error Temperature drift Fits to following systems Phase error Temperature drift Fits to following systems Phase error Dedicated Instruments Clamps & Ampflex Working temperature Temperature drift Connector type Safety banana jacks (4 mm) for CLAMP-20-B Fits to following systems DEWE-5xx-PNA, DEWE-5xx-PNA-1MS for PNA-CLAMP-20 All systems with DAQ and HSI series amplifiers for PNA-CLAMP-20-B Current range Cont. current measurement Overload capability Output sensitivity...

Open the catalog to page 3
Current Transducers with high precision - 4

Current Measurement Sensors Phase error Temperature drift Connector type Safty banana sockets (4 mm) Fits to following systems All system with DAQ and HSI series amplifiers Phase error Working temperature -10° to +55°C (maximum temperature for sensor is 90°C) Temperature drift Connector type Safty banana jacks (4 mm) Fits to following systems All systems with DAQ and HSI series amplifiers Phase error Working temperature -10° to +55°C (maximum temperature for sensor is 90°C) Temperature drift Connector type Safty banana jacks (4mm) Fits to following systems All systems with DAQ and HSI...

Open the catalog to page 4

All DEWETRON GmbH catalogs and technical brochures

  1. CVT Logger

    1 Pages

  2. DEWE-2600

    3 Pages

  3. DEWE2

    46 Pages

Archived catalogs

  1. DEWE-CLOCK

    2 Pages

  2. TRION Series

    18 Pages

  3. DEWE-501

    4 Pages

  4. Mainframes

    16 Pages