Specifications:
  • Output Power: 6-24 Watts
  • Input LC Filter: Ensures EMI filtering
  • Footprint: 24-pin DIL
  • Regulated Outputs: Provides stable voltage output
  • Overcurrent Protection: 120%-150% of rated current
  • Non-Isolated Outputs: Direct connection without isolation
Technical Data:
  • Switching Frequency: 150kHz
  • Load Regulation: ±0.5%
  • Line Regulation: ±0.5%
  • Ripple & Noise: 3.3/5V: 100mVpp max; 12/15V: 1% Vpp max
  • Efficiency: Less than 94%
  • Operating Temperature: -25°C to +71°C without derating; 71°C to 100°C with derating (-3.5%/°C)
  • Storage Temperature: -40°C to +100°C
  • Temperature Coefficient: ±0.05%/°C
  • Dimensions: 32 x 20 x 10mm
  • Weight: 12g
Product Variants: The document lists several models with varying input and output specifications, such as EDR7W5R3,3 with 4.7-6VDC input and 3.3VDC output, and EDR24W24R15 with 19-32VDC input and 15VDC output.
Operational Guidelines: All data is measured at nominal input, full load, and 25°C ambient temperature unless otherwise specified. The document notes that technical modifications and errors are reserved, and stresses under 'Maximum Rating' may be applied without permanent damage, though extended operation at these limits may affect reliability.
Pin Assignment: The document provides a pin assignment diagram for proper connection and usage.
Contact Information: Deutronicstr. 5, D - 84166 Adlkofen, Tel: +49 (0) 8707 920-199, Fax: +49 (0) 8707 1004, Email: [email protected], Website: http://www.deutronic.com
See more

Catalog excerpts

EDR-1

EDR geregelter Schaltregler, 6-24 Watt, Weitbereichseingang regulated switching regulator, 6-24 watt, wide range input Ausgangsleistung 6-24 Watt LC-Eingangsfilter Passend in 24-poliges DIL-Raster Ausgänge geregelt Überstrombegrenzung Nicht galvanisch getrennt 6-24W outputs Input LC filter Footprint 24-pin DIL Regulated outputs Over current protection Non-isolated outputs Input voltage Output voltage Output Current Input current no load full load Schaltregler switching regulator Alle Daten bei nominaler Eingangsspannung, Volllast und 25 Umgebungstemperatur gemessen, wenn nicht anders gekennzeichnet. All data at nominal input, full load and 25 C ambient temperature, if not marked otherwise. Technische Änderungen und Irrtümer vorbehalten. Technical modifications and mistakes reserved. Mit den Angaben im Katalog und in den Datenblättern werden Produkte beschrieben, nicht Eigenschaften zugesichert. Belastung mit „Grenzwerten“ (einfache Kombination) ist zulässig ohne bleibende Schäden der Produkte. Betrieb der Geräte mit Grenzwertbelastung für längere Zeit kann die Zuverlässigkeit beeinträchtigen. Grenzwerttoleranzen unterliegen üblichen Schwankungen. Products are described by information contained in catalogs and data-sheets. It is not be considered as assured qualities. Stresses listed under „Maximum Rating“ (one at a time) may be applied to devices without resulting in permanent damage. The operation of the equipment for extended periods may affect device reliability. Limiting value tolerance are subject to usual fluctuation margins Stand 21.03.06 Seite 1 edr.doc

 Open the catalog to page 1
EDR-2

Eingang Input Eingangsspannung Input voltage Filterung EMI filter siehe Tabelle see table LC-Filter Ausgang Output Ausgangsspannung Output voltage Ausgangsgenauigkeit Output accurancy Überstrombegrenzung Over current protection Schaltfrequenz Switching frequency Regelabweichung bei Laständerung Load regulation Regelabweichung bei Eingangsänderung Line regulation Restwelligkeit 20MHz Ripple & noise (p-p) 20MHz Umgebung Environment Arbeitstemperatur -25°C bis +71°C ohne Derating 71°C bis 100°C mit Derating (-3.5%/°C) -25°C to +71°C without derating 71°C to 100°C with derating (-3.5%/°C) -40°C~+100°C...

 Open the catalog to page 2
EDR-3

Derating Curve : Load (%) 100 -3.5%/°C a. Operating Temperature : -25°C to 71°C ---> without derating b. Operating Temperature : 71°C to 100°C ---> derating (-3.5%/°C) Schaltregler switching regulator Alle Daten bei nominaler Eingangsspannung, Volllast und 25 Umgebungstemperatur gemessen, wenn nicht anders gekennzeichnet. All data at nominal input, full load and 25 C ambient temperature, if not marked otherwise. Technische Änderungen und Irrtümer vorbehalten. Technical modifications and mistakes reserved. Mit den Angaben im Katalog und in den Datenblättern werden Produkte beschrieben, nicht Eigenschaften...

 Open the catalog to page 3

All DEUTRONIC catalogs and technical brochures

  1. DVCH3003-700

    8  Pages

  2. DVCH3003-400

    8  Pages

  3. DVCH1503-700

    7  Pages

  4. DVCH1503

    9  Pages

  5. ESC15H

    3  Pages

  6. ETC70H

    3  Pages

  7. DVC75

    4  Pages

  8. DR25N 25

    3  Pages

  9. EHB50W

    5  Pages

  10. EHB200W

    4  Pages

  11. E0,25K

    3  Pages

  12. ET40

    3  Pages

  13. E-TOP 480/3W

    4  Pages

  14. D-IPS 150

    6  Pages

  15. E-TOP 5

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.