X-GCU B and X-GCU GT are robust control units designed as data acquisition boards for Aurora series powered detector subsystems. They enable the integration of multiple Aurora X-Cards, facilitating the creation of high-performance X-ray imaging systems. These units are GigE compatible, allowing for high data throughput and connection of numerous X-Cards.
Both X-GCU B and X-GCU GT feature compact mechanical sizes and include on-board signal processing and diagnostic functions. They come with demonstration software, a control library, and sample source code to expedite evaluation and software development.
| Parameter | X-GCU GT | X-GCU B |
|---|---|---|
| Product code | 3000024722 | 13013560 |
| Input voltage | 10.8 V - 26.4 V DC | 10.8 V - 26.4 V DC |
| Typical power consumption | 4 W | 3 W |
| Number of segments | 5 | 2 |
| Max number of X-Cards per segment | 16 | 12 |
| Max total number of X-Cards | 80 | 24 |
| Max pixel quantity | 10240 | 3072 |
| Max cable length between X-GCU and X-Card | 3 m | 2 m |
| Min integration time | 100 us | 1.27 ms |
| Max integration time | Up to 25 ms | Up to 25 ms |
| System linearity | >99 % | >99 % |
| Supported interface | GigE | GigE |
| EMC standards of trigger interface | ESD: 8 kV contact, 15 kV air discharge; EFT: 2 kV; Surge: 6 kV | ESD: 8 kV contact, 15 kV air discharge; EFT: 2 kV; Surge: 1 kV |
| Max throughput | 600 Mbps | 600 Mbps |
| Voltage sensor | Yes | Yes |
| Temperature sensor | Yes | Yes |
| Humidity sensor | Yes | Yes |
| Mechanical dimensions (with thermal pad) | 132 mm (L) x 58 mm (W) x 20.2 mm (H) | 132 mm (L) x 58 mm (W) x 19.8 mm (H) |
X-GCUAurora series control units X-GCU B and X-GCU GT are robust control units that operate as data acquisition boards in Aurora series powered detector subsystems. Combining a number of Aurora X-Cards with the series optimized X-GCU makes it easy to build high performance and reliable X-ray imaging subsystems. The GigE compatible control units provide a connection of up to 80 pieces of 64-channel, dual-energy Aurora X-Cards while enabling high data throughput speed. X-GCU B and X-GCU GT have a compact mechanical size, and both solutions come with on-board signal processing and diagnostic functions. Demonstration software, a control library and a sample source code are available to speed up evaluation and software development. KEY FEATURES • Configurable line stamp function with external RS-485 triggers • Remote firmware upgrade • Gigabit Ethernet interface • Auto-recovery • Software development kit available for rapid evaluation and software development • EMC compliance APPLICATIONS • Security inspection • Cargo and vehicle inspection • Multi-view imaging • Non-destructive testing • Food inspection • Raw material sorting • Thickness measurement • Foreign particle detection • CT imaging BENEFITS • Makes it easy to build high performance and reliable X-ray imaging subsystems • Provides a connection of up to 80 pieces of 64-channel dual-energy Aurora X-Cards • High throughput data transfer speed of up to 600 Mbps • Easy-to-use • Compact mechanical size • On-board signal processing functions - Offset and gain calibrations, adaptive constant integration time, pixel binning, line summing and averaging functions and pixel discontinuity correction • Diagnostics functions - Data test patterns, remotely readable temperature sensor, humidity sensor, voltage monitoring and stat
Open the catalog to page 1Product code Input voltage Typical power consumption Max number of X-Cards per segment Max total number of X-Cards Max pixel quantity Max cable length between X-GCU and X-Card Min integration time System linearity Supported interface GigE ESD: 8 kV contact, 15 kV air discharge EFT: 2 kV Surge: 6 kV EMC standards of trigger interface ESD: 8 kV contact, 15 kV air discharge EFT: 2 kV Surge: 1 kV Voltage sensor Temperature sensor Humidity sensor Mechanical dimensions (with thermal pad) X-GCU B. Basic system typology. Trigger generator X-Link 26 pin ribbon cable X-GCU Trigger cable GigE cable X-Link...
Open the catalog to page 26 Pages
2 Pages
4 Pages
2 Pages
2 Pages
4 Pages
6 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages