Catalog excerpts
X-GCUAurora series control units X-GCU B and X-GCU GT are robust control units that operate as data acquisition boards in Aurora series powered detector subsystems. Combining a number of Aurora X-Cards with the series optimized X-GCU makes it easy to build high performance and reliable X-ray imaging subsystems. The GigE compatible control units provide a connection of up to 80 pieces of 64-channel, dual-energy Aurora X-Cards while enabling high data throughput speed. X-GCU B and X-GCU GT have a compact mechanical size, and both solutions come with on-board signal processing and diagnostic functions. Demonstration software, a control library and a sample source code are available to speed up evaluation and software development. KEY FEATURES • Configurable line stamp function with external RS-485 triggers • Remote firmware upgrade • Gigabit Ethernet interface • Auto-recovery • Software development kit available for rapid evaluation and software development • EMC compliance APPLICATIONS • Security inspection • Cargo and vehicle inspection • Multi-view imaging • Non-destructive testing • Food inspection • Raw material sorting • Thickness measurement • Foreign particle detection • CT imaging BENEFITS • Makes it easy to build high performance and reliable X-ray imaging subsystems • Provides a connection of up to 80 pieces of 64-channel dual-energy Aurora X-Cards • High throughput data transfer speed of up to 600 Mbps • Easy-to-use • Compact mechanical size • On-board signal processing functions - Offset and gain calibrations, adaptive constant integration time, pixel binning, line summing and averaging functions and pixel discontinuity correction • Diagnostics functions - Data test patterns, remotely readable temperature sensor, humidity sensor, voltage monitoring and stat
Open the catalog to page 1Product code Input voltage Typical power consumption Max number of X-Cards per segment Max total number of X-Cards Max pixel quantity Max cable length between X-GCU and X-Card Min integration time System linearity Supported interface GigE ESD: 8 kV contact, 15 kV air discharge EFT: 2 kV Surge: 6 kV EMC standards of trigger interface ESD: 8 kV contact, 15 kV air discharge EFT: 2 kV Surge: 1 kV Voltage sensor Temperature sensor Humidity sensor Mechanical dimensions (with thermal pad) X-GCU B. Basic system typology. Trigger generator X-Link 26 pin ribbon cable X-GCU Trigger cable GigE cable...
Open the catalog to page 2All Detection Technology catalogs and technical brochures
-
X-scan ME Series
6 Pages
-
X-panel 2301
2 Pages
-
X-panel 1214i
4 Pages
-
X-GCU
2 Pages
-
X-Scan C01
2 Pages
-
X-Panel 1615
4 Pages
-
Aurora CT
6 Pages
-
X-scan T series
2 Pages
-
X-IM ME3
2 Pages
-
X-Card ME3
4 Pages
-
X-Array series
2 Pages
-
DT X-card DE & SE
2 Pages
-
DT X-Scan C5 series
2 Pages
-
X -Scan M01B series
2 Pages
-
X-Scan H01 series
2 Pages
-
Aurora series
4 Pages
-
X-Scan P01 series
2 Pages
-
X-card2 Series
2 Pages
-
X-Scan F01 series
2 Pages
-
X-Tile
2 Pages
-
x-scan il2-de series
2 Pages
-
X-DAQ
2 Pages
-
X-Scan M series
2 Pages
-
X-Scan F5 Series
2 Pages
-
X-Scan c5 Series
2 Pages
-
X-Scan U Series
2 Pages
-
X-Scan D Series
2 Pages
-
Security Applications
2 Pages
-
X-Scan LCS Series
2 Pages
-
X-card
2 Pages
-
Digital X-Card
2 Pages
Archived catalogs
-
X-Panel 2301 brochure
2 Pages
-
X-Panel 1511
2 Pages
-
X-Scan f5
2 Pages
-
X-CGU
2 Pages
-
X-Scan iL2 DE Series
2 Pages
-
X-Scan iHE2 Series
2 Pages
-
X-Card2
2 Pages
-
X-Scan U3
2 Pages
-
X-Scan U-Shape
2 Pages
-
X-Scan iHE
2 Pages
-
Photodiode 550 nm | PDC series
2 Pages
-
X-ray detector card X-Card SE-X
2 Pages