1. Catalogs
  2. DETAS
  3. GSA SWD0.2

GSA SWD0.2

GSA SWD0.2
1 / 32 PagesView full catalog

GSA SWD0.2

Product catalog summary
Technical Specifications and Standards:
The document details compliance with international standards such as TUV EN 60950-1, CE, and various EN standards for electromagnetic compatibility and safety, as well as CCC standards for China.
Physical Characteristics:
The power supply units are compact, measuring 90 x 22.5 x 114 mm, made of plastic, and weigh 150 g. They are designed for easy snap-on mounting on DIN rails.
Installation and Cooling:
Installation requires natural convection cooling with a recommended 25 mm free space on all sides. The units use screw terminals suitable for AWG26-12 cables.
Electrical Specifications:
The power supplies have a universal input voltage range of 90-265 VAC and offer high efficiency up to 86%. They include short circuit protection and internal input filters.
Output Specifications:
Output voltage accuracy is within ±2%, with no minimum load requirement. The transient recovery time is 300 µs, and ripple and noise level is 50 mV.
Models and Performance:
Several models are listed with varying output voltages and currents, highlighting efficiency and specific operational conditions. Models are available on request with minimum purchase quantities.
Control and Protection:
The units feature an internal input fuse and overload protection, with some models offering a DC OK static output for relay connections.
Construction and Design:
The design allows for secure mounting on DIN rails without tools, emphasizing ease of installation and maintenance.
Overview:
This document provides technical specifications and installation guidelines for DETAS SpA's AC-DC DIN rail mountable power supplies, specifically models GSA SWD02, GSA SWD04, and GSA SWD05, designed for high efficiency and reliability.
Specifications:
  • Input Voltage: Universal input range of 90-264 VAC for models GSA SWD02 and GSA SWD04, and selectable 115/230 VAC for model GSA SWD05.
  • Output Voltage and Current: Models offer various output voltages (12V, 24V, 48V) with corresponding output currents.
  • Efficiency: High efficiency up to 87% depending on the model and configuration.
  • Protection Features: Includes short circuit protection, over voltage protection, and internal surge voltage protection.
  • Environmental Specifications: Operating temperature range from -35°C to +71°C, with derating above 61°C. Storage temperature range from -40°C to +85°C.
Installation and Construction:
  • Mounting: Easy snap-on installation onto DIN-Rail (TS35/7.5 or TS35/15) without tools.
  • Cooling: Natural convection cooling is recommended, with 25 mm of free space on all sides.
  • Connector Specifications: Supports AWG24-10 flexible/solid cables, with specific torque requirements for input and output connectors.
Approvals and Standards:
  • Complies with UL, cUL, TUV, and CE standards, ensuring safety and reliability.
  • Meets several EN standards for electromagnetic compatibility and safety, including EN 60950-1 and EN 61000 series.
Additional Features:
  • Indicators: Equipped with DC ON and DC LOW LED indicators for operational status and voltage drop alerts.
  • Parallel Operation: Supports parallel operation for increased power output, with specific guidelines for load sharing.
General Specifications:
- Switching frequency: 80 KHz at nominal input and output.
- Isolation voltage: 3000 VAC between input and output.
- Isolation resistance: 100 MΩ at 500 VDC.
- Operating temperature: -15 to +71 °C.
- Storage temperature: -25 to +85 °C.
- Relative humidity: 20 to 95% RH.
- Dimensions: 123.6 x 63.5 x 126.6 mm.
- Cooling: Free air convection.
Input Specifications:
- Rated input voltage: 115/230 VAC, selectable.
- Input voltage range: 93-132 VAC for 115V, 186-264 VAC for 230V, 210-370 VDC for DC.
- Line frequency: 47-63 Hz.
- Inrush current: 24/48 A at 115/230 VAC.
- Power factor correction (PFC): 0.7 at 230 VAC.
Output Specifications:
- Output voltage accuracy: -0 to +2%.
- Minimum load: 5%.
- Line regulation: ±0.5%.
- Load regulation: ±1%.
- Temperature coefficient: ±0.02%/°C.
- Ripple and noise: 50 mV.
- Hold up time: 25/30 ms at 115/230 VAC.
- Voltage trim range: 11.4-14.5 VDC for 12V model, 22.5-30 VDC for 24V model, 45-55 VDC for 48V model.
- Efficiency: Up to 87%.
Control and Protection:
- Input fuse: T4A/250 VAC internal.
- Overload protection: 105-125%.
- Over voltage protection: 125-145%.
- Output short circuit: Current limited.
Physical Characteristics:
- Case material: Metal.
- Weight: 860 g.
- Easy snap-on mounting on DIN-Rail (TS35/7.5 or TS35/15).
Approvals and Standards:
- UL/cUL: UL 508 Listed, UL60950-1 Recognized.
- TUV: EN 60950.
- CE: EN 61000-6-3, EN 55022 Class B, EN 61000-3-2, EN 61000-3-3, EN 61000-6-2, EN 55024.
Installation and Cooling: The power supply unit is designed for easy snap-on mounting onto a DIN-Rail (TS35/7.5 or TS35/15). It requires 25 mm of free space on all sides for natural convection cooling. The connector size range is AWG24-10 (0.2~4 mm2) for flexible or solid cables. The input connector can withstand a maximum torque of 1.02 Nm, while the output connector can withstand up to 0.62 Nm. It is recommended to strip 8 mm at the cable end and use copper conductors rated at 60/75°C.
General Tolerance: The general tolerance for dimensions is specified as follows: 0.00 - 30.00 mm ±0.30 mm, 30.00 - 120.00 mm ±0.50 mm, and 120.00 - 400.00 mm ±0.80 mm.
Approvals and Standards: The unit complies with several standards including UL/cUL (UL 508 Listed, UL 60950-1 Recognized), ISA 12.12.01, TUV EN 60950-1, EN 61558-1, EN 61558-2-17, CE, and CCC. It meets various EN standards for electromagnetic compatibility and safety.
Vibration and Shock Resistance: The unit is tested for vibration resistance according to IEC 60068-2-6 and shock resistance according to IEC 60068-2-27.
Model Specifications: The GSA SWD20/24 model operates with an input voltage range of 90-264 VAC, providing an output of 24 VDC at 20 A with an efficiency of up to 89%. The GSA SWD20/48 model offers 48 VDC at 10 A with up to 90% efficiency.
General Specifications: The switching frequency is 60 KHz, with an isolation voltage of 3000 VAC between input and output. The operating temperature range is -40 to +71°C, with a derating of 2.5% per °C above 56°C. The unit has a MTBF of 403,000 hours for the 24 V model and 416,000 hours for the 48 V model.
Input Specifications: The rated input voltage is 115/230 VAC, with a maximum input range of 90-264 VAC. The input current is 4.9/2.5 A at 115/230 VAC. The unit features active PFC with a power factor of 0.99/0.97.
Output Specifications: The output voltage accuracy is within +1%, with a minimum load of 0%. The unit supports parallel operation for up to 3 units and has a ripple and noise level of 100 mV.
Control and Protection: The unit includes an internal input fuse, surge voltage protection, and overload protection. It also features a DC ON indicator and a DC LOW voltage indicator.
Physical Characteristics: The unit measures 124.5 x 175.5 x 123.6 mm and weighs 1920 g. It is housed in a metal case with an IP20 protection rating.
See more

Catalog excerpts

GSA SWD0.2-1

AC-DC DIN rail mountable power supply Features • UL / cUL / UV / CE • Universal input 90÷264 VAC • Short circuit protection • Internal input filter modelli - Model List Codice Code Tensione d'ingresso Input voltage Potenza d'uscita Output wattage Tensione d'uscita Output voltage Efficienza - Efficiency Corrente d'uscita Output current Modelli ad uscita singola - Single Output models GSA SWD0.2/05 * Modelli disponibili solo su richiesta e per quantitativi minimi d'acquisto. - Models available only on request and purchase of minimum quantity. Tutti i dati tecnici sono riferiti a tensione d'ingresso nominale, a pieno carico e a 25 °C salvo diversa specifica. All specifications typical at nominal line, full load, 25°C unless otherwise noticed. Specifiche Generali - General Specifications Valore - Value Condizioni - Conditions Caratteristiche - Characteristics Frequenza di switching - Switching frequency Tensione di isolamento - Isolation voltage Input-Output Input-FG Resistenza di isolamento - Isolation resistance Derating (vedi curva - see curve) Temperatura d'esercizio - Ambient temperature Altitudine di funzionamento - Altitude during operation Dimensione - Dimension Versione morsetti a vite - Screw terminal type Raffreddamento - Cooling ±0.03 5 V model 12 V model 15 V model 24 V model MTBF (tempo medio tra i guasti) Coefficiente di temperatura - Temperature coefficient Temperatura di stoccaggio - Storage temperature Umidità relativa - Relative humidity Convezione naturale - Free air convection Grado di inquinamento - Pollution degree © 2012 DETAS SpA - Via Treponti, 29 - 25086 Rezzato (BS) ITALY Tel. +39 030 2594120 - Fax +39 030 2792864 - [email protected] - www.detas.com Alimentatori AC-DC montabili su guida DIN Caratteristiche • UL / cUL / TUV / CE • Ingresso universale 90÷264 VAC • Protezione da corto circu

 Open the catalog to page 1
GSA SWD0.2-2

alimentatori - power supplies Specifiche d'ingresso - Input Specifications Caratteristiche - Characteristics Tensione d'ingresso nominale - Rated input voltage Valore - Value Condizioni - Conditions Massimo intervallo di tensione in ingresso Absolute input max. range Corrente di picco all'accensione - Inrush current Corrente di perdita - Leakage current Dissipazione di potenza - Power dissipation Frequenza di rete - Line frequency Assorbimento nominale max. in ingresso - Rated input current Assorbimento in ingresso - Input current Input-Output Input-FG 5 V model 12 V model 15 V model 24 V model...

 Open the catalog to page 2
GSA SWD0.2-3

GSA SWD0.2 Omologazioni e standard - Approvals and Standards UL / cUL EN 60950-1, CB scheme EN 61000-6-3, EN 55022 classe B, EN 61000-3-2, EN 61000-3-3 EN 61000-6-2, EN 55024, EN 61000-4-2 Level 4, EN 61000-4-3 Level 3 EN 61000-4-4 Level 4, EN 61000-4-5 L-N Level 3, L/N-FG Level 4 EN 61000-4-6 Level 3, EN 61000-4-8 Level 4, EN 61000-4-11 ENV 50204 Level 2, EN 61204-3 Resistenza alle vibrazioni - Vibration resistance IEC 60068-2-6 (Montaggio su guida-mounting by rail: 10-500 Hz, 2G, 60 min. ogni asse X, Y, Z-each axis X, Y, Z.) Resistenza agli urti - Shock resistance IEC 60068-2-27 (15G, 11ms,...

 Open the catalog to page 3
GSA SWD0.2-4

alimentatori - power supplies CIRCUITO schematico - Circuit Schematic Limitazione - Typical Current Limited Curve DERATING - Derating Curve rendimento - Typical Efficiency Curve © 2012 DETAS SpA - Via Treponti, 29 - 25086 Rezzato (BS) ITALY Tel. +39 030 2594120 - Fax +39 030 2792864 - [email protected] - www.detas.com

 Open the catalog to page 4
GSA SWD0.2-5

AC-DC DIN rail mountable power supply Features • UL / cUL / UV / CE • Universal input 90÷264 VAC • Short circuit protection • Internal input filter modelli - Model List Codice Code Tensione d'ingresso Input voltage Potenza d'uscita Output wattage Tensione d'uscita Output voltage Efficienza - Efficiency Corrente d'uscita Output current Modelli ad uscita singola - Single Output models GSA SWD0.75/05 * Modelli disponibili solo su richiesta e per quantitativi minimi d'acquisto. - Models available only on request and purchase of minimum quantity. Tutti i dati tecnici sono riferiti a tensione d'ingresso...

 Open the catalog to page 5
GSA SWD0.2-6

alimentatori - power supplies Specifiche d'ingresso - Input Specifications Caratteristiche - Characteristics Tensione d'ingresso nominale - Rated input voltage Valore - Value Condizioni - Conditions Massimo intervallo di tensione in ingresso Absolute input max. range Corrente di picco all'accensione - Inrush current Corrente di perdita - Leakage current Dissipazione di potenza - Power dissipation Frequenza di rete - Line frequency Assorbimento nominale max. in ingresso - Rated input current Assorbimento in ingresso - Input current Input-Output Input-FG 5 V model 12 V model 15 V model 24 V model...

 Open the catalog to page 6
GSA SWD0.2-7

GSA SWD0.75 Omologazioni e standard - Approvals and Standards UL / cUL EN 60950-1, CB scheme EN 61000-6-3, EN 55022 Class B, EN 61000-3-2, EN 61000-3-3 EN 61000-6-2, EN 55024, EN 61000-4-2 Level 4, EN 61000-4-3 Level 3 EN 61000-4-4 Level 4, EN 61000-4-5 L-N Level 3, L/N-FG Level 4 EN 61000-4-6 Level 3, EN 61000-4-8 Level 4, EN 61000-4-11 ENV 50204 Level 2, EN 61204-3 Resistenza alle vibrazioni - Vibration resistance IEC 60068-2-6 (Montaggio su guida-mounting by rail: 10-500 Hz, 2G, 60 min. ogni asse X, Y, Z-each axis X, Y, Z.) Resistenza agli urti - Shock resistance IEC 60068-2-27 (15G, 11ms,...

 Open the catalog to page 7
GSA SWD0.2-8

alimentatori - power supplies CIRCUITO schematico - Circuit Schematic GSA SWD0.75/24 Limitazione - Typical Current Limited Curve GSA SWD0.75/24 GSA SWD0.75/24 DERATING - Derating Curve rendimento - Typical Efficiency Curve © 2012 DETAS SpA - Via Treponti, 29 - 25086 Rezzato (BS) ITALY Tel. +39 030 2594120 - Fax +39 030 2792864 - [email protected] - www.detas.com

 Open the catalog to page 8
GSA SWD0.2-9

AC-DC DIN rail mountable power supply Features • UL / cUL / UV / CE • Universal input 90÷265 VAC • High efficiency up to 84% • Short circuit protection • Internal input filter modelli - Model List Codice Code Tensione d'ingresso Input voltage Potenza d'uscita Output wattage Tensione d'uscita Output voltage Corrente d'uscita Output current Modelli ad uscita singola - Single Output models GSA SWD01/05 * Modelli disponibili solo su richiesta e per quantitativi minimi d'acquisto. - Models available only on request and purchase of minimum quantity. Tutti i dati tecnici sono riferiti a tensione d'ingresso...

 Open the catalog to page 9

All DETAS catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.