DESMI OptiPower Power Quality and Active Harmonic Filters for Marine Electrical Network Reliability PROVEN TECHNOLOGY DESMI
Open the catalog to page 1OptiPower OptiPower includes everything from power quality analysis to design and implementation of power quality enhancing equipment. OptiPower’s active filter is a key component for optimal power quality
Open the catalog to page 2What Causes Harmonics in Marine Applications? Power electronics with rapid and frequent variations of is damaged. Motors are at risk of overheating and loads provide many process-related control and energy becoming noisy, and torque oscillations in the rotor can saving benefits, leading to the growing abundance of result in mechanical resonance and vibration. If a capacitor these types of devices on board vessels and in offshore overheats, in the most severe cases, the breaking down of marine applications. the dielectric creates an explosion risk. Additionally, the However, these non-linear loads...
Open the catalog to page 3Global Solution: Electrical System Level Active Filter The active filter monitors the mains current to determine the amount of harmonic current correction that must be injected to create a sinusoidal AC current and minimize the harmonic current. An active filter is installed parallel to the inverters with the CT on the mains feeder to effectively compensate for harmonics to the 50th order. Figure 4: Simplified illustration of an active filter Active Filter Advantages • Highly effective ◦◦2nd to 50th orders cancelled • Connected in parallel ◦◦Not critical for equipment operation • Scalable parallel...
Open the catalog to page 4OptiPower PCS+ Active Harmonic Filter Highest Possible Flexibility during the Design and Installation Phase • Harmonics mitigation, displacement power factor correction, and mains current balancing ◦◦When applied fully, OptiPower PCS+ provides optimized fuel usage for the prime mover of a generator. • Flexible equipment installation and optimized space utilization ◦◦Modular OptiPower PCS+ (IP20, IP31 or IP54) can be installed parallel to the generator and the loads. • Load share or cascade operation of paralleled units ◦◦Operate up to 10 units in parallel and up to 3000 amperes correction at...
Open the catalog to page 5Global Solution: Electrical System Level OptiPower with Schneider electric active filter solutions PCS+ Key features and main benefits • Voltage: 208 - 480 V AC, 600 V AC, 690 V AC • 3-phase supply 208 - 480V: 60, 120, 200, 300A • 3-phase supply 600 V: 47, 94, 157, 235A • 3-phase supply 690 V: 40, 80, 133, 200A • Harmonic compensation: H2 to H50, discrete spectrum cancellation • Reactive compensation: power factor correction, cos φ to near unity, selectable set point • Load balancing of source current • Electrical systems: 3-wire or 4-wire • Product standards: CE Certified, UL, cUL, CSA, ABS,...
Open the catalog to page 6Measurements give you the facts you need Net Analysis - When You Need to be in Control of Power Quality Measurements and Reports - What do We Offer? An overview of the Power Quality in the installations we measure, but it is also possible to calculate the values. • Measurements on site with calibrated network analyzing equipment. The Power Quality analyzing instrument can measure • Measurement report Harmonics, Power, Energy, V/A/HZ and DPF which makes • Analysis and conclusion on measurements it possible to see whether it is possible to improve the • Advice in connection with installation
Open the catalog to page 7Read more about OptiPower at www.desmi.com or contact us by phone: +45 96 32 81 11
Open the catalog to page 812 Pages
8 Pages
20 Pages
16 Pages
20 Pages
16 Pages
2 Pages
2 Pages
2 Pages
4 Pages
8 Pages
4 Pages
4 Pages
2 Pages
2 Pages
12 Pages
2 Pages
2 Pages
16 Pages
16 Pages
2 Pages
8 Pages
8 Pages
16 Pages
8 Pages
8 Pages
2 Pages
24 Pages
12 Pages
4 Pages
4 Pages
12 Pages
8 Pages
56 Pages
1 Page
2 Pages
24 Pages
8 Pages
28 Pages
2 Pages
20 Pages
2 Pages
2 Pages
2 Pages
12 Pages
2 Pages
2 Pages
4 Pages
4 Pages
1 Page
2 Pages
2 Pages
2 Pages
1 Page
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
20 Pages
20 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
8 Pages
8 Pages
8 Pages
12 Pages
8 Pages
2 Pages
4 Pages
1 Page