ATEX directive

ATEX directive

ATEX directive

Product catalog summary
Overview: This document provides guidelines for the use of ROTAN® pumps in potentially explosive atmospheres, in compliance with the ATEX directives 94/9/EC and 1999/92/EC. It outlines the responsibilities of manufacturers and end-users, safety measures, and classification of equipment and zones.
Scope: The directives apply to non-electrical equipment and protective systems used in explosive atmospheres, including gases, vapors, mists, and dusts. Both manufacturers and end-users must comply with these regulations from June 30, 2006.
Manufacturer and Supplier Responsibilities: Manufacturers must ensure equipment meets directive 94/9/EC requirements and is appropriately marked. They must consider ignition sources and use suitable materials, avoiding those like aluminum and titanium that could cause sparks.
End-User Responsibilities: End-users must prevent explosions by following directive 1999/92/EC, which includes creating an Explosion Protection Document, assessing risks, and clearly marking danger zones. They must ensure equipment surface temperatures do not exceed specified limits.
Normal and Abnormal Conditions: ROTAN® pumps are designed for specific applications, with normal conditions detailed in data sheets. Abnormal conditions require continuous monitoring for deviations such as leaks or incorrect operation.
Ignition Source and Safety Standards: Risk assessments consider all pump components. Standards EN 13463-1, 5, and EN 1127-1 are applied to ensure safety against explosions.
Temperature and Zone Classification: Pumps are classified by temperature classes (T1 to T6) and zones (0, 1, 2 for gases; 20, 21, 22 for dusts) based on the likelihood of explosive atmospheres.
Protective Measures: Optional safety features include temperature monitoring (PT100 sensors), pressure relief valves, and dry run protection. Installation must follow DESMI A/S instructions.
ATEX Marking and Compliance: Equipment must be marked according to ATEX standards, indicating group, category, and zone suitability. Changes to equipment must be approved to maintain ATEX compliance.
Qualified Personnel: Maintenance and inspection must be conducted by trained personnel familiar with area classification principles. DESMI provides certified personnel for equipment modifications.
Contact Information: For further assistance, DESMI can be contacted via their website or phone.
See more

Catalog excerpts

ATEX directive-1

ROTAN and the ATEX directives 94/9/EC and 1999/92/EC Superior guideline for users of equipment in potential explosive atmospheres

 Open the catalog to page 1
ATEX directive-2

ROTAN® Pumps and the ATEX directives Scope The European Parliament has agreed that as from June 30 2006 the same regulations will apply to both manufacturer/supplier and end-user in the EC when operating non-electrical equipment and protective systems intended for use in potentially explosive atmospheres i.e., gas, vapour, mist and dusts. This means that equipment for use in potentially explosive atmospheres has to follow directive 94/9/ EC and 1999/92/EC . This document describes "Equipment- GROUP II category 2” and the precautions to be taken for ROTAN® pumps intended for use in zone 1 and...

 Open the catalog to page 2
ATEX directive-3

The following devices are optional or additional safety features: Temperature monitoring • PT 100 sensor • Temperature labels Protection against momentary pressure rise inside the pump • Integral pressure relief valve Protection against dry run • 'Liquiphant' (resonance probe) by Endress Hause for viscosities up to 10.000 cSt pressure up to 64 bar / 28 psi. Notes 1. Directive 94/9/EC of the European Parliament and the Council of 23 March 1994 on the approximation of the laws of the Member States concerning equipment and protective systems intended for use in potentially explosive atmospheres....

 Open the catalog to page 3
ATEX directive-4

V ROTAN’ can supply equipment under: Category 1 Zone 0 - GAS Areas with a gas/air mixture occur continuous or for longer periods. Zone 20 - DUST Areas where a cloud of combustible dust occur continuous or for longer periods. Category 2 Zone 1 - GAS Areas where a gas/air mixture occur occasional. Zone 21 - DUST Areas where a cloud of combustible dust occur occasional. Category 3 Zone 2 - GAS Areas where a gas/air mixture occur exceptionally or for short periods. Zone 22 - DUST Areas where a cloud of combustible dust occur exceptionally or for short periods. The temperature class is among others...

 Open the catalog to page 4
ATEX directive-6

PT100 sensor To ensure that a ROTAN® ATEX pump is safe to use in an ATEX-defined area the following instructions must be followed. ED pumps and pumps with soft shaft seal must always be installed with a PT100 sensor according to DESMI A/S instructions. If the ROTAN® ATEX pump is fitted with a bypass valve, a PT100 sensor has to be mounted on the bypass valve. If a ROTAN® ATEX pump is ordered with PT100 sensor, the PT100 sensor is not mounted from the factory, due to the risk of damaging it during transport. Before the first start up of the pump the PT100 sensor must be mounted in accordance with...

 Open the catalog to page 6
ATEX directive-7

ROTAN® Pumps and the ATEX directives 94/9EC and 1999/92EC Technical dossier Group II Area G - Gas D - Dust Category 2 High protection level Zone 1 - Incidental presence of explosive atmosphere during normal duty, in mixture of gas/air, vapour/air or mist/air Zone 21 - Incidental presence of explosive atmosphere during normal duty, in mixture of dust/air Category 3 Normal protection level Zone 2 - Presence of explosive atmosphere only by accident, but not during normal duty, in mixture of gas/air, vapour/air or mist/air Zone 22 - Presence of explosive atmosphere only by accident, but not during...

 Open the catalog to page 7
ATEX directive-8

You can read more about industry solutions at www.desmi.com or contact us at +45 ad more about our pump solutions at www.desmi.com96 MARINE & OFFSHORE

 Open the catalog to page 8

All DESMI Pumping Technology A/S catalogs and technical brochures

  1. AquaCulture

    16  Pages

  2. ROTAN® ED

    2  Pages

  3. ROTAN® PD

    2  Pages

  4. ESL & ESLH

    2  Pages

  5. NSL

    4  Pages

  6. DESMI Grafter

    4  Pages

  7. CS Boom

    4  Pages

  8. Ro-Kite

    2  Pages

  9. Oilfence

    2  Pages

  10. Arctic range

    16  Pages

  11. OIL FENCE

    2  Pages

  12. DESMI KaziCat

    4  Pages

  13. Commissioning

    4  Pages

  14. DESLUBE

    1  Page

  15. Modular S

    2  Pages

  16. Company profile

    24  Pages

  17. Pyroboom

    8  Pages

  18. OptiSave

    20  Pages

  19. OptiClean

    2  Pages

  20. NSLV/NSLH

    4  Pages

  21. Modular H

    1  Page

  22. ESL

    2  Pages

  23. OptiPower

    8  Pages

  24. DSL

    2  Pages

  25. NSA

    1  Page

  26. SA

    2  Pages

  27. VAC

    2  Pages

  28. PVLN

    2  Pages

  29. A-BOOM

    2  Pages

  30. ALLIGATOR

    2  Pages

  31. CRANE SWEEPER

    2  Pages

  32. TRAILER

    2  Pages

  33. POLLCAT

    2  Pages

  34. POLLKITTEN

    2  Pages

  35. POLLCRAFT

    2  Pages

  36. RO-MAR

    2  Pages

  37. WINDERS

    2  Pages

  38. HOSE REEL

    2  Pages

  39. GLOBEBOOM

    2  Pages

  40. NS-1B

    2  Pages

  41. NS-1S

    2  Pages

  42. NS-2B

    2  Pages

  43. NS-2S

    2  Pages

  44. NS-3B

    2  Pages

  45. OS-1B

    2  Pages

  46. OS-1S

    2  Pages

  47. OS-2B

    2  Pages

  48. OS-2S

    2  Pages

  49. POLLUTANK

    2  Pages

  50. PyroBoom®

    2  Pages

  51. ROTAN PD

    2  Pages

  52. ROTAN HD

    2  Pages

  53. ROTAN GP

    2  Pages

  54. Ethanol Syrup

    2  Pages

  55. ROTAN ED

    2  Pages

  56. ROTAN CD

    2  Pages

  57. Cargo

    8  Pages

  58. DESMI 48

    8  Pages

  59. Asphalt

    2  Pages

  60. Chocolate

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.