DSE7310-20
1 / 4Pages

Catalog excerpts

DSE7310-20 - 1

® DSECONTROL® MONITORING WITH INTELLIGENCE. The DSE7310 and DSE7320 are control modules for single gen-set applications. The modules have been developed from the successful DSE5310 and DSE5320 Series and incorporate a number of advanced features to meet the most demanding on-site applications. The DSE7310 is an Automatic Start Control Module and the DSE7320 is an Auto Mains (Utility) Failure Control Module. Both modules have been designed to start and stop diesel and gas generating sets that include electronic and non-electronic engines. The DSE7320 includes the additional capability of being able tomonitor a mains (utility) supply. Both modules include USB, RS232 and RS485 ports as well as dedicated DSENet® terminals for expansion device connectivity. The modules are simple to operate and feature a userfriendly menu layout for improved clarity. Enhanced features include a real time clock for enhanced event and performance monitoring, ethernet communications for low cost monitoring, mutual standby (DSE7310 only) to reduce engine wear and tear and preventative maintenance features to detect engine part faults prior to a major problem occurring. FEATURES • Backed up real time clock • 132 x 64 pixel LCD display • Configurable display languages • Five-key menu navigation • Fully configurable via PC software • LED and LCD alarm indication • Engine exercise mode • Configurable start & fuel outputs • kWh monitoring • Automatic load transfer • Eight configurable digital inputs • Six configurable outputs • Configurable timers and alarms • Modbus RTU • Magnetic pick-up • Selected front panel programming • Multiple date and time exercise scheduler • SMS messaging (additional external modem required) • Power save mode • User selectable RS232 & RS485 communications • DSENet® compatible • Ethernet communications via DSE860/865 • Multiple date and time maintenance scheduler • Configurable display pages • Programmable load shedding/acceptance • Preventative maintenance • kW overload protection • Unbalanced load protection • Flexible sender input • Configurable SCADA output page • True dual mutual standby with load balancing timer (DSE7310 only) • Fan control for additional cooling • ‘Protections Disabled’ facility • Fuel usage monitoring and low fuel alarm • Support for up to three remote display units • Automatic sleep mode • Easy access, configurable diagnostics page shows summary of output states • Improved programmable event log (250) showing date and time • Manual fuel pump control • 3 alternative configurations • Multiple date and time scheduler • 3 Programmable Maintenance alarms with comms alert • Customisable status screens • Low fuel level alarm delay • Charge alternator fail warning and shutdown alarms with user programmable delay • Independent Earth fault trip • Sleep mode • Load switching (Load shedding and dummy load outputs) • Manual speed trim (on CAN engines that support this feature) • Additional display screens to help with modem diagnostics • Security levels – PC software has password system to control access to PC software features • Operator configurable virtual LEDs visible in SCADA NEWFEATURES • Additional programmable logic • Improved modem diagnostics • Remote control sources (10) can be accessed via SCADA • Additional electrical trip options • Additional start delay functions • Oil pressure values from additional engines • Front panel editing of scheduler • Displays kW as % of rated kW setting DSE7310 & DSE7320 AUTO START & AUTOMAINS FAILURE CONTROLMODULES (COMMUNICATIONS & EXPANSION) SPECIFICATION DC SUPPLY ALTERNATOR INPUT MAINS/UTILITY INPUT (DSE7320 ONLY) CONTINUOUS VOLTAGE RATING 8V to 35V Continuous CRANKING DIP PROTECTION Able to survive 0V for 50mS, providing supply was at least 10V before dropout and supply recovers to 5V. This is achieved without the need for internal batteries CHARGE FAIL/ EXCITATION 0V to 35V fixed power source 2.5W MAXIMUM STANDBY CURRENT 160mA at 12V 80mA at 24V MAXIMUM OPERATING CURRENT 340mA at 12V 160mA at 24V RANGE 15V - 333V (L-N) 50Hz - 60Hz (Minimum 15V AC Ph-N) ACCURACY 1% of full scale true RMS sensing SUPPORTED TOPOLOGIES 3 phase 4 wire 3 phase 3 wire 3 phase 4 wire Delta Single phase 2 wire 2 phase 3 wire L1 & L2 2 phase 3 wire L1 & L3 RANGE 15V - 333V (L-N) 50Hz - 60Hz (Minimum 15V AC Ph-N) ACCURACY 1% of full scale true RMS sensing SUPPORTED TOPOLOGIES 3 phase 4 wire 3 phase 3 wire 3 phase 4 wire Delta Single phase 2 wire 2 phase 3 wire L1 & L2 2 phase 3 wire L1 & L3 CT’S BURDEN 0.5VA PRIMARY RATING 1A - 8000A (user selectable) SECONDARY RATING 1A or 5A secondary (user selectable) ACCURACY OFMEASUREMENT 1% of full load rating RECOMMENDATIONS Class 1 required for instrumentation Protection class required if using for protection Continued on page 2

Open the catalog to page 1
DSE7310-20 - 2

BENEFITS • 132 x 64 pixel ratio makes information easy to read • Real time clock provides accurate event logging • PC software is license free • Set maintenance periods can be configured to maintain optimum engine performance • Ethernet communications provides advanced remote monitoring at low cost • Modules can be integrated into building management systems • Preventative maintenance avoids expensive engine down time • Advanced PCB layout ensures high reliability • Robust design • Extensive performance monitoring OPERATION The modules are operated via the START, STOP, AUTO and MANUAL soft...

Open the catalog to page 2
DSE7310-20 - 3

® DSE7310 & DSE7320 BATTERY -VE +VE CHG ALT OIL WATER FUEL (FLEXIBLE) SENDER COMMON FLEXIBLE 8 INPUTS PLANT +VE GENERATOR LOADING RELAY OUTPUT D MAINS LOADING RELAY(7320) OUTPUT C (ALL MODELS) FLEXIBLE IF J1939 IN USE FLEXIBLE IF J1939 IN USE 4 FET OUTPUTS ENGINE ECU MPU SCR SCR H L BATTERY NEGATIVE MUST BE GROUNDED TERMINALS SUITABLE FOR 22-16 AWG (0.6mm - 1.3mm ) FIELD WIRING TIGHTENING TORQUE = 0.8Nm (7lb-in) NOTE 1 THESE GROUND CONNECTIONS MUST BE ON THE ENGINE BLOCK, AND MUST BE TO THE SENDER BODIES. THE GROUND WIRE TO TERMINAL 15 MUST NOT BE USED TO PROVIDE A GROUND CONNECTION TO ANY...

Open the catalog to page 3

All DES catalogs and technical brochures

  1. dseL401 MKII

    2 Pages

  2. DSE9462

    2 Pages

  3. DSE9480 MKII

    2 Pages

  4. DSE4510 MKII

    2 Pages

  5. DSE4610

    2 Pages

  6. DSE6110 MKII

    2 Pages

  7. DSE7110 MKII

    2 Pages

  8. dse9120-9240

    2 Pages

  9. dse860-65

    1 Pages

  10. dse330

    2 Pages

  11. dse9480

    2 Pages

  12. edv-015-1250

    2 Pages

  13. dse705-4130

    2 Pages

  14. dse330-

    2 Pages

  15. dse8700

    2 Pages

  16. dse431020

    2 Pages

  17. dse335

    2 Pages

  18. dse3210-

    2 Pages

  19. 500

    2 Pages

  20. 1000

    2 Pages

  21. DSE5310-5320

    4 Pages

  22. DSE7210-20

    4 Pages

  23. DSE7110-20

    4 Pages

  24. DSE704-4120

    2 Pages

  25. DSE705-4130

    2 Pages

  26. DSE710-720

    2 Pages

  27. DSE703-4110

    2 Pages

  28. DSE4410-20

    2 Pages

  29. DSE6110-20

    2 Pages

  30. DSE511

    2 Pages

  31. DSE512

    2 Pages

  32. DSE402

    2 Pages

  33. DSE501K

    2 Pages

  34. DSE8700

    2 Pages

  35. DSE3110

    2 Pages

Archived catalogs

  1. DSE5210-5220

    4 Pages