ENVIRONMENTAL TESTING STANDARDS ELECTRO-MAGNETIC COMPATIBILITY BS EN 61000-6-2 EMC Generic Immunity Standard for the Industrial Environment BS EN 61000-6-4 EMC Generic Emission Standard for the Industrial Environment AUTO TRANSFER SWITCH FEATURES The DSE705 and DSE4130 are Transfer Switch Control Modules that have been designed to monitor the mains (utility) supply. When the mains (utility) power fails, the module will send a start request to the generator control unit. When the generator is up and running the module transfers the load across. When the mains (utility) returns, the module transfers the load back and removes the start command. The generator should then begin its shutdown procedure. ELECTRICAL SAFETY BS EN 60950 Safety of Information Technology Equipment, including Electrical Business Equipment The modules can be configured to follow the users’ pre-set start and stop sequences. TEMPERATURE BS EN 60068-2-1 Ab/Ae Cold Test -30 oC BS EN 60068-2-2 Bb/Be Dry Heat +70 oC The DSE4130 case includes a closed back. VIBRATION BS EN 60068-2-6 Ten sweeps in each of three major axes 5 Hz to 8 Hz @ +/-7.5 mm, 8 Hz to 500 Hz @ 2 gn HUMIDITY BS EN 60068-2-30 Db Damp Heat Cyclic 20/55 oC @ 95% RH 48 Hours BS EN 60068-2-78 Cab Damp Heat Static 40 oC @ 93% RH 48 Hours SHOCK BS EN 60068-2-27 Three shocks in each of three major axes 15 gn in 11 mS DEGREES OF PROTECTION PROVIDED BY ENCLOSURES BS EN 60529 IP65 - Front of module when installed into the control panel with the sealing gasket (to be ordered seperately). COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF ATS APPLICATIONS 2 CLOSE TO NEUTRAL POSITION REMOTE START START/RUN OUTPUT MAINS (UTILITY) SENSING CLOSE MAINS NEGATIVE DC OUTPUT CLOSE GENERATOR NEGATIVE DC OUTPUT GENERATOR SENSING ALL OUTPUTS ARE -VE SWITCHING SOLID STATE
Open the catalog to page 1AUTO TRANSFER SWITCH DC SUPPLY CONTINUOUS VOLTAGE RATING 8 V to 35 V continuous CRANKING DROPOUTS Able to survive 0V for 50mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries. MAXIMUM OPERATING CURRENT 50 mA at 12 & 24 V MAXIMUM STANDBY CURRENT DSE705 10 mA at 12 V & 24 V DSE4130 15 mA at 12 V & 24 V ALTERNATOR INPUT RANGE 75 V to 333 V AC absolute maximum ALTERNATOR INPUT FREQUENCY 50Hz – 60Hz at rated engine speed (minimum:75 V AC L-N) OUTPUTS START & RUN OUTPUT 1.2 Amp DC at supply voltage. Switches to battery...
Open the catalog to page 22 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages