Overview: The document provides specifications and operational details for the DSE705 and DSE4130 Auto Transfer Switch Control Modules, designed to monitor and manage the transition between mains (utility) power and generator power.
Specifications:
  • Automatic Monitoring: Both modules automatically monitor the mains supply and initiate generator start upon failure.
  • Load Transfer: They facilitate automatic load transfer between mains and generator.
  • Manual and Automatic Modes: The modules can be operated manually or set to automatic mode for seamless operation.
  • Configuration: User-configurable settings allow customization of start and stop sequences.
  • Environmental Standards: Compliant with various BS EN standards for electromagnetic capability, temperature, vibration, humidity, and shock.
  • Power Supply: Operates on a DC supply range of 8V to 35V, with specific current requirements for each module.
  • Dimensions: Detailed dimensions and cutout sizes are provided for both modules.
Features:
  • Automatic mains supply monitoring and load changeover control.
  • Protected Solid State outputs and front panel programming.
  • LED indicators and configurable timers and outputs.
  • Single/three-phase mains sensing and remote start input.
Benefits:
  • Facilitates seamless power transfer between mains and generator.
  • On-site configuration to meet specific user requirements.
Operation:
  • Manual Off Load: Manually start and run the engine off load.
  • Manual On Load: Manually start and run the engine on load.
  • Auto Mode: Automatically detects mains failure and initiates generator start.
Environmental Testing Standards:
  • EMC Generic Emission Standards: BS EN 61000-6-2 and BS EN 61000-6-4.
  • Temperature: BS EN 60068-2-2 and BS EN 60068-2-1.
  • Vibration: BS EN 60068-2-6.
  • Humidity: BS 2011 part 2.1 60068-2-30.
  • Shock: BS EN 60068-2-27.
Configuration: Modules can be configured via a rear switch, with detailed instructions available in the installation manuals.
Contact Information: Provided for Deep Sea Electronics Inc. and Deep Sea Electronics PLC, including addresses, phone numbers, and websites.
See more

Catalog excerpts

DSE705-4130-1

® DSEULTRA® STARTING WITH QUALITY. SPECIFICATION ENVIRONMENTAL TESTING STANDARDS The DSE705 and DSE4130 are Auto Transfer Switch ControlModules that have been designed to monitor the mains (utility) supply. When the mains (utility) power fails the modules send a start request to the generator control unit. When the generator is up and running the modules transfer the load across.When the mains (utility) returns, the modules transfer the load back and remove the start command. The generator should then begin its shutdown procedure. Both modules can be configured so that they follow the users pre-set start and stop sequences. The DSE4130 enclosure has a closed back. FEATURES • Automatic mains (utility) supply monitoring • Load changeover control • Manual start • Protected Solid State (PSS) outputs • Front panel mounting • Front panel programming • LED indicators • Configurable timers • Configurable outputs • Single/three phase mains sensing • Remote start input BENEFITS • Transfers between mains and generator power • On-site module configuration to match user requirements OPERATION The modules are operated using the three push buttons on the front: MANUALOFF LOAD - This is used to manually start and run the engine off load. Should the mains (utility) supply fail, then the load is transferred to the generator automatically. MANUALONLOAD - This mode is used to manually start and run the engine on load. AUTOMODE - This puts the module into automatic mode, where it will await a mains (utility) failure. Upon detection it will send a start request to the generator control unit. ELECTROMAGNETIC CAPABILITY BS EN 61000-6-2 EMC Generic Emission Standard for the Industrial Environment BS EN 61000-6-4 EMC Generic Emission Standard for the Industrial Environment TEMPERATURE BS EN 60068-2-2 Test Ab to +70oC 60067-2-2 Hot Test Ab to -30oC 60068-2-1 Cold VIBRATION BS EN 60068-2-6 Ten sweeps in each of three major axes 5Hz to 8Hz @ +/-7.5mm, 8Hz to 500Hz @ 2gn HUMIDITY BS 2011 part 2.1 60068-2-30 Test Cb Ob Cyclic 93% RH @ 40oC for 48 hours SHOCK BS EN 60068-2-27 Three shocks in each of three major axes 15gn in 11mS DC SUPPLY 8V to 35V continuous CRANKING DROPOUTS Able to survive 0V for 50mS, providing supply was at least 10V before dropout and supply recovers to 5V. This is achieved without the need for internal batteries. MAXIMUM OPERATING CURRENT 50mA(12V and 24V) (DSE4130 only) 50mA (DSE705 only) TYPICAL CURRENT 15mA(12V and 24V) (DSE4130 only) 12mA (DSE705 only) ALTERNATOR INPUT RANGE 75V(L-N) to 333V AC (L-N) absolute maximum ALTERNATOR INPUT FREQUENCY 50Hz – 60Hz at rated engine speed (minimum:75V AC L-N) START & RUN OUTPUTS 1.2 Amp DC at supply voltage. Switches to battery negative when active CLOSE GEN/MAINS CONTROL OUTPUTS 1.2 Amp DC at supply voltage. Switches to battery negative when active AUXILIARY OUTPUTS 1.2 Amp DC at supply voltage. Switches to battery negative when active DSE705 DIMENSIONS 165mm x 125mm x 29mm 6.5” x 4.9” x 1.2” DSE705 CUT OUT 149mm X 109mm 5.9” x 4.3” DSE4130 DIMENSIONS 171mm x 115mm x 49mm 6.75’’ x 4.5’’ x 2’’ DSE4130 CUT OUT 154mm x 98mm 6.1” x 3.9” DSE705 & DSE4130 AUTO TRANSFER SWITCH CONTROLMODULES DSE705 DSE4130

 Open the catalog to page 1
DSE705-4130-2

® CONFIGURATION The modules can be configured to match user’s individual parameter settings. Configuration mode is accessed via the switch at the rear of the module. Once in configuration mode the AUTO-LED flashes rapidly. Please refer to the installation instructions for the parameter settings and full configuration information. RELATEDMATERIALS TITLE PART NO’S DSE705 Installation Instructions 053-037 DSE705 Operators Manual 057-044 DSE4130 Installation Instructions 053-024 DSE4130 Operators Manual 057-024 DEEP SEA ELECTRONICS INC 3230 Williams Avenue Rockford IL 61101-2668 USA TELEPHONE +1...

 Open the catalog to page 2

All DES catalogs and technical brochures

  1. dseL401 MKII

    2  Pages

  2. DSE9462

    2  Pages

  3. DSE9480 MKII

    2  Pages

  4. DSE4510 MKII

    2  Pages

  5. DSE4610

    2  Pages

  6. DSE6110 MKII

    2  Pages

  7. DSE7110 MKII

    2  Pages

  8. dse9120-9240

    2  Pages

  9. dse860-65

    1  Page

  10. dse330

    2  Pages

  11. dse9480

    2  Pages

  12. edv-015-1250

    2  Pages

  13. dse705-4130

    2  Pages

  14. dse330-

    2  Pages

  15. dse8700

    2  Pages

  16. dse431020

    2  Pages

  17. dse335

    2  Pages

  18. dse3210-

    2  Pages

  19. 500

    2  Pages

  20. 1000

    2  Pages

  21. DSE5310-5320

    4  Pages

  22. DSE7210-20

    4  Pages

  23. DSE7310-20

    4  Pages

  24. DSE7110-20

    4  Pages

  25. DSE704-4120

    2  Pages

  26. DSE710-720

    2  Pages

  27. DSE703-4110

    2  Pages

  28. DSE4410-20

    2  Pages

  29. DSE6110-20

    2  Pages

  30. DSE511

    2  Pages

  31. DSE512

    2  Pages

  32. DSE402

    2  Pages

  33. DSE501K

    2  Pages

  34. DSE8700

    2  Pages

  35. DSE3110

    2  Pages

Archived catalogs

  1. DSE5210-5220

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.