® DSEULTRA® STARTING WITH QUALITY. SPECIFICATION The DSE6010 is an Auto Start ControlModule and the DSE6020 is an AutoMains (Utility) Failure ControlModule for single gen-set applications. Bothmodules have been designed to work with electronic and non electronic engines providing advanced engine monitoring and protection features. Themodules include a backlit LCD display which clearly shows the status of the engine at all times. Theymonitor, speed, frequency, voltage, current, oil pressure, coolant temperature and fuel level. Themodules have also been designed to display the warning and shutdown status of the engine. Bothmodules include seven inputs and six outputs. Four outputs are configurable on themagnetic pick-up version and six are configurable on the CANbus version. Themodules can either be programmed using the front panel or by using the DSE Configuration Suite PC software. CONFIGURATION The modules can be configured using the front panel or by remote PC using a USB connection lead and the DSE Configuration Suite PC software. FEATURES • CAN and magnetic pick-up versions (specify on ordering) • PC and front panel configurable • 4 digital inputs/ 3 analogue inputs • 6 outputs (4 configurable on Magnetic Pick-Up, 6 configurable on CANbus version) • 3 Phase generator and mains (utility) voltage monitoring (mains on DSE6020 only) • Event log (5) events • Configurable timers • Automatic shutdown or warning when fault conditions are detected • Remote start on or off load • Engine pre-heat • Advanced metering capability • Engine hours counter • Red LED indicator for warning or shutdown • Icon LCD Display • Protected Solid State Outputs (PSS) • Test button (DSE6120 only) BENEFITS • Transfer between mains (utility) and generator power (DSE6020 only) • Hours counter provides accurate information for monitoring and maintenance periods • User-friendly set-up and button layout • Multiple engine parameters are monitored simultaneously • Module can be configured to suit individual applications • Wide range of engines can be specified • Uses the DSE Configuration Suite PC Software for simplified programming • IP65 rating offers advanced resistance to water ingress when gasket is fitted • License free PC software OPERATION Manual Mode • The engine is started using the HAND button and the Start button on the front of the module. • Once pressed the module instructs the engine to initiate its pre-heat sequence and then start the engine. • To stop the engine the Stop button on the front of the module is pressed. Automatic Mode • The Auto button is pressed to put the unit in Auto Mode. • The module start sequence is initiated by the activation of the remote start input or mains failure. • The pre-heat sequence is then initiated and the engine is started. • To stop the engine the remote start signal is removed or the Stop button on the module is pressed. • AMF function. OVERSPEED PROTECTION The engine over speed trip setting can be calibrated for 50Hz or 60Hz nominal operation. ELECTRONIC ENGINE COMPATIBILITY • CAT • Cummins • Deutz • John Deere • MTU • Perkins • Scania • Volvo • Generic • Plus additional manufacturers DC SUPPLY 8V to 35V Continuous CRANKING DROPOUTS Able to survive 0V for 50mS, providing supply was at least 10V before dropout and supply recovers to 5V. This is achieved without the need for internal batteries. LEDs and backlight will not be maintained during cranking. MAXIMUMOPERATING CURRENT 150mA at 12V 80mA at 24V MAXIMUMSTANDBY CURRENT 50mA at 12V 30mA at 24V GENERATOR INPUT RANGE 15V to 333V AC (L-N) absolute maximum 50Hz - 60Hz (min 15V AC) CHARGE FAIL/EXCITATION RANGE 0V to 35V VOLTAGE RANGE 0.5V RMS minimum FREQUENCY RANGE 10,000 Hz (max) 15V to 333V AC (L-N) absolute maximum 25V to 576V AC (L-L) absolute maximum 50Hz - 60Hz (min 15V AC) OVERALL 216mm x 158mm x 42mm 8.5” x 6.2” x 1.6” PANEL CUT-OUT 182mm x 137mm 7.2” x 5.4” MAXIMUMPANEL THICKNESS 8mm. 0.3” DSE6010 & DSE6020 AUTO START & AUTOMAINS (UTILITY) FAILURE CONTROLMODULES DC SUPPLY MAGNETIC PICKUP OUTPUTS DIMENSIONS MAINS (UTILITY) SENSING INPUT RANGE (DSE4420 ONLY) OUTPUT A (FUEL) 2 Amp DC at supply voltage OUTPUT B (START) 2 Amp DC at supply voltage AUXILIARY OUTPUTS C,D,E & F 2 Amp DC at supply voltage NEW RELEASE
Open the catalog to page 1® RELATEDMATERIALS TITLE PART NO’S DSE6010 Installation Instructions 053-076 DSE6020 Installation Instructions 053-077 60xx PC Configuration Suite Manual 057-114 60xx Operator Manual 057-112 DEEP SEA ELECTRONICS INC 3230 Williams Avenue Rockford IL 61101-2668 USA TELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708 EMAIL [email protected] WEBSITE www.deepseausa.com DEEP SEA ELECTRONICS PLC Highfield House Hunmanby Industrial Estate Hunmanby, North Yorkshire YO14 0PH England TELEPHONE +44 (0)1723 890099 FACSIMILE +44 (0)1723 893303 EMAIL [email protected] WEBSITE www.deepseaplc.com Registered...
Open the catalog to page 22 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages