dse330- - 1

ENVIRONMENTAL TESTING STANDARDS ELECTRO-MAGNETIC COMPATIBILITY BS EN 61000-6-2 EMC Generic Immunity Standard for the Industrial Environment BS EN 61000-6-4 EMC Generic Emission Standard for the Industrial Environment AUTO TRANSFER SWITCH CONTROL MODULE FEATURES The DSE330 is an Automatic Transfer Switch Controller. The DSE330 will monitor the voltage and frequency of the incoming AC supply from two different sources, which could be from both generator or mains (utility), or a combination of both. The module will monitor S1 (source 1) and in the event of a failure will issue a start command to S2 (source 2). Once S2 is available and producing an output within limits, the module will control the transfer device and switch the load from S1 to S2. Once the S1 supply returns to within limits, the module will command a load return to S1 and shut down S2. ELECTRICAL SAFETY BS EN 60950 Safety of Information Technology Equipment, including Electrical Business Equipment Various timing sequences are available to prevent nuisance starting on minor supply breaks. Configurable digital inputs and outputs make the DSE330 fully flexible to suit a wide variety of applications. TEMPERATURE BS EN 60068-2-1 Ab/Ae Cold Test -30 oC BS EN 60068-2-2 Bb/Be Dry Heat +70 oC VIBRATION BS EN 60068-2-6 Ten sweeps in each of three major axes 5 Hz to 8 Hz @ +/-7.5 mm, 8 Hz to 500 Hz @ 2 gn The module can be easily configured using the DSE Configuration Suite PC Software. Where there is no DC supply a DSE160 self seeking power supply is required. HUMIDITY BS EN 60068-2-30 Db Damp Heat Cyclic 20/55 oC @ 95% RH 48 Hours BS EN 60068-2-78 Cab Damp Heat Static 40 oC @ 93% RH 48 Hours The DSE330 also supports many topologies, and includes a clear back-lit LCD display, showing system operational status and warnings. SHOCK BS EN 60068-2-27 Three shocks in each of three major axes 15 gn in 11 mS DEGREES OF PROTECTION PROVIDED BY ENCLOSURES BS EN 60529 IP65 - Front of module when installed into the control panel with the supplied sealing gasket. COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF ATS APPLICATIONS PC 2 CONFIGURABLE INPUTS

Open the catalog to page 1
dse330- - 2

AUTO TRANSFER SWITCH CONTROL MODULE DC SUPPLY CONTINUOUS VOLTAGE RATING 8 V to 35 V Continuous CRANKING DROPOUTS Able to survive 0 V for 50 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries. LEDs and backlight will not be maintained during cranking. MAXIMUM OPERATING CURRENT 61 mA at 12 V, 62 mA at 24 V MAXIMUM STANDBY CURRENT 50 mA at 12 V, 51 mA at 24 V OUTPUTS AUXILIARY OUTPUTS A,B,C,D,E & F 2 A DC at supply voltage S1 & S2 VOLTAGE RANGE 15 V to 333 V AC (L-N) FREQUENCY RANGE 3.5 Hz to 75 Hz...

Open the catalog to page 2

All DES catalogs and technical brochures

  1. dseL401 MKII

    2 Pages

  2. DSE9462

    2 Pages

  3. DSE9480 MKII

    2 Pages

  4. DSE4510 MKII

    2 Pages

  5. DSE4610

    2 Pages

  6. DSE6110 MKII

    2 Pages

  7. DSE7110 MKII

    2 Pages

  8. dse9120-9240

    2 Pages

  9. dse860-65

    1 Pages

  10. dse330

    2 Pages

  11. dse9480

    2 Pages

  12. edv-015-1250

    2 Pages

  13. dse705-4130

    2 Pages

  14. dse8700

    2 Pages

  15. dse431020

    2 Pages

  16. dse335

    2 Pages

  17. dse3210-

    2 Pages

  18. 500

    2 Pages

  19. 1000

    2 Pages

  20. DSE5310-5320

    4 Pages

  21. DSE7210-20

    4 Pages

  22. DSE7310-20

    4 Pages

  23. DSE7110-20

    4 Pages

  24. DSE704-4120

    2 Pages

  25. DSE705-4130

    2 Pages

  26. DSE710-720

    2 Pages

  27. DSE703-4110

    2 Pages

  28. DSE4410-20

    2 Pages

  29. DSE6110-20

    2 Pages

  30. DSE511

    2 Pages

  31. DSE512

    2 Pages

  32. DSE402

    2 Pages

  33. DSE501K

    2 Pages

  34. DSE8700

    2 Pages

  35. DSE3110

    2 Pages

Archived catalogs

  1. DSE5210-5220

    4 Pages