RoCoil TCA-5
1Pages

{{requestButtons}}

Catalog excerpts

RoCoil TCA-5 - 1

POWER REQUIREMENTS The DENT RoCoil TCA-5 delivers the flexibility and ease-of-installation of the RoCoil current sensors to applications using power meters with 5A current transformer inputs. Used with standard RoCoil flex CTs, the TCA-5 is a three-channel integrating transconductance amplifier that translates the electrical output signal from the RoCoil current sensor to a 5 amp AC current, emulating a traditional current sensing transformer. The RoCoil TCA-5 is a DIN rail or panel mounted device requiring an external 48 VDC power supply. The RoCoil TCA-5 has four selectable current ranges: 500, 1K, 2.5K, and 5K amps and selectable frequency for both 50 and 60 Hz systems. Input Measurement Voltage Reference Conductor Current Range Output Current RoCoil Sensing Ranges Maximum Burden Maximum Output Impedance Measurement Channels Frequency Accuracy Channel Cross Talk Maximum Operating Temperature RoCoil TCA-5™ PART NUMBERS TCA Supply Current Part Number AC/DC Power Supply, 48 VDC Low Voltage: 120/240 VAC High Voltage: 400/500 VAC RoCoil TCA-5 . For use with DENT RoCoil CTs. Does not include power supply or RoCoil CTs. (Not UL Listed unless used with DENT Instruments' supplied Power Supply—see below). Mounting Rail TCA-5-HV-KIT DIMENSIONS/MOUNTING RoCoil TCA-5. For use with DENT RoCoil CTs. Includes 48 VDC High Voltage (400/500 VAC) power supply for use on 480V 3-phase services (line-to-line) , wiring harness, and TS35/7 DIN rail. Does not include RoCoil CTs. Width-Base Unit Width—As Assembly Height-Base Unit Height—As Assembly RoCoil TCA-5. For use with DENT RoCoil CTs. Includes 48 VDC Low Voltage (120/240 VAC) power supply for use on residential 1-phase services & 208V 3-phase, wiring harness, and TS35/7 DIN rail. Does not include RoCoil CTs. Input Wire Connection TCA-HV-POWER Output Wire Connection 48 VDC High Voltage power supply for use on 3-phase services. Use with RoCoil TCA-5. TCA-LV-POWER 48 VDC Low Voltage power supply for use on single-phase services. Use with RoCoil TCA-5. *Only 4.5 Amps are available on single-phase loads if all three channels are on the same phase. **All accuracies specified at 20°C (±2°C) with RoCoil™ centered on conductor with unity power factor. CONTACT US DENT Instruments, Inc. Energy & Power Measurement Solutions An ISO 9001:2008 Certified Company © DENT Instruments, Inc. rev 082415 All specifications subject to change without notice. 925 SW Emkay Drive Bend, Oregon 97702 USA 541.388.4774 | 800.388.0770 www.DENTinstruments.com

Open the catalog to page 1

All DENT INSTRUMENTS catalogs and technical brochures

  1. 1000A Clamp

    1 Pages

  2. RoCoil

    1 Pages

  3. RoCoil mV

    1 Pages

  4. 72" RoCoil

    1 Pages