Catalog excerpts
RoCoil mV Millivolt Output Flex CTs The DENT RoCoil mV™Flexible Current Transformers have been designed for accurate measurement of AC current with a safe, millivolt output. 36", 3000A, 30—3900A AC 72", 6000A, 60—6000A AC Output Signal 333 mV AC at rated current Max output 1,665 mVAC Accuracy < 1% typical at 2% to 500% of rated current *Depending on meter compatibility. See ELITEpro™ and PowerScout™ specifications for details. ELECTRICAL All accuracies specified at 20°C (±2°C) with RoCoil mV™ centered on conductor. Output Signal Max Output Power Requirement Wire Color Phasing Phase Shift 5-24 VDC, 30 mA Maximum Red = Power (+) Black = Power (-) White = Signal (+) Green = Signal (-) Arrow Points Towards Load < 1° at rated current DIMENSIONS Frequency Range Linearity Conductor Position Sensitivity Influence of External Field Temperature Sensitivity MECHANICAL A Window Size B Transformer Coil O.D. D Locking Connector O.D. E Transformer Coil Diameter F Wire Lead Total Length G Length of mV Module H Width of mV Module Coil Material Blue thermoplastic rubber, flame retardant UL 94 V-0 rated Coupling Materials Polypropylene UL 94 V-0 rated Case Material abs ul 94 V-0 rated Shielding 85% transducer, 100% output lead SAFETY Working Voltage Dielectric Strength Certifications 7400 VAC around coil 600 VAC rated leads Conforms to UL STD 61010-1 Certified to CAN/CSA STD C22.2 No. 61010 RoCoil mV PART NUMBERS* TJ 3" 0) V) CD m 16" RoCoil mV™ 24" RoCoil mV™ 36" RoCoil mV™ 72" RoCoil mV™ CONTACT US *Other Sizes, currents, and outputs are available. Please contact the factory for details. AVAILABLE OPTIONS *PX-ADPT Power Cable from Line-Powered ELITEpro for powering up to 4 CTs *PX-ADPT-EXC Adapter and Power Cable for powering up to 4 RoCoil mV CTs from the ELITEpro XC or SP. *PX-XFMR-EXC Wall Transformer plus Power Cable capable of powering up to 925 SW Emkay Drive DENT Instruments, Inc. Ben0, Oreg°n 977o2 usa Energy & Power Measurement Solutions 541.388.4774 | 800.388.0770 www.DENTinstruments.com All specifications contained in this document are subject to change without notice. © DENT INSTRUMENTS, INC. rev 102814
Open the catalog to page 1All DENT INSTRUMENTS catalogs and technical brochures
-
PowerScout 3 HD
3 Pages
-
1000A Clamp
1 Pages
-
RoCoil
1 Pages
-
RoCoil TCA-5
1 Pages
-
RoCoil vs RoCoil mV
1 Pages
-
72" RoCoil
1 Pages
-
150A EZ Clamp
1 Pages
-
100A Midi Hinged CT
1 Pages
-
600/1000A Large
1 Pages
-
50/100A Small Data Sheet
1 Pages
-
SMARTlogger Data Sheet
2 Pages
-
PowerScout 3037/24 Datasheet
2 Pages
-
ELITEpro XC Datasheet
8 Pages