PowerScout 3037/24 Datasheet
2Pages

{{requestButtons}}

Catalog excerpts

PowerScout 3037/24 Datasheet - 1

POWERSCOUT™ 3037 REVENUE-GRADE SINGLE-POINT POWER METER POWERSCOUT™ SPECIFICATIONS ADAPT TO ANY PROJECT The PowerScout 3037 comes in four basic configurations depending on whether a display or Ethernet port are desired. Instead of having one specific meter for a single job, the PowerScout 3037 can adapt to nearly any project requirement. All PowerScout 3037 models have a broadband power supply (80-600VAC) and can be paired with a variety of current transformers, from split cores that measure <1A up to large RoCoils designed for measuring 4000A. In addition, communication protocols are field-selectable. Easily toggle between Modbus or BACnet using ViewPoint software. QUICK & EASY SETUP Configuring the PowerScout 3037 for a new project is faster than ever before, thanks to the standard USB port. To configure, simply connect the meter to a PC using a USB cable, then use ViewPoint software to select CT type, communication protocol, and other parameters. The meter is powered by the USB port while connected to a PC. Have several meters that require the same configuration? Save your setup table in ViewPoint and use it over and over. FASTEST & EASIEST INSTALLATION The PowerScout 3037 is compact enough to facilitate inpanel mounting. Or, use the built-in DIN rail channel, which is compatible with TS35/7 rail for quick and easy mounting near the circuit panel. PowerScout instruments are line-powered and do not require external power. Its power supply can accommodate service voltages ranging from 80-600V (phase-to-phase). DENT's patented PhaseChek™ circuitry includes a 3 bi-color LED indicator display that confirms proper CT-to-phase placement and orientation. Use the standard USB connection to easily power and configure the PowerScout 3037 at your office or in the field. Once connected to the panel, USB can also be used to verify setup and check real-time values. POWERSCOUT 3037 ANATOMY Optional Display for quickly reading real-time values & performing diagnostics PhaseChek™ LEDs to verify CT-to-phase installation Angled Mounting Tabs for easy installation in or near the panel. PowerScout PS30371 Network Power Meter Modbus/BACnet Address Switches Standard USB powers the meter and allows for easy setup. Standard pulse output for sending pulses to an external device CT Connectors: Easily switch between RoCoil & Split Core CTs Voltage Connection: Broadband power supply operates on services up to 600VAC REVENUE-GRADE PERFORMANCE The PowerScout 3037 features revenue-grade ANSI C12.20-2010 qualified Class 0.2 performance. Paired with the appropriate DENT CTs, the PowerScout 3037 is ideal for high-accuracy applications like demand response or tenant submetering. COMMUNICATIONS: INDUSTRY-STANDARD MODBUS OR BACNET Communications interface to the PowerScout 3037 can be accomplished through serial RS-485 or USB, or optional Ethernet. The PowerScout can use either the BACnet IP or MS/TP protocol or Modbus TCP or RS-485 protocol for sending commands or retrieving data. STANDARD PULSE OUTPUT Send kWh or other pulses to an external device. The pulse output is used to generate system kWh pulses for devices, such as data loggers, that can accept pulses, but do not have BACnet or Modbus capability. VIEWPOINT SOFTWARE POWERSCOUT™ SERIES NETWORKED POWER METERS SAFETY MODBUS REGISTER/BACNET OBJECT DESCRIPTIONS (PARTIAL LIST) * For DC applications, please see manual for full specifications and application details. Use on 120/240V, 480/277V, 580/355V, or 380/220V services. 50 or 60 Hz. VIEWPOINT™ SOFTWARE: QUICK AND EASY SET-UP, CONFIGURATION, & DIAGNOSTICS DENT's ViewPoint software utility allows you to easily configure the PowerScout for the connected CTs and to check real-time values to ensure that the meter is properly configured. ViewPoint is the quick and easy way to: • Switch between communication protocols • Verify meter installation • Check real-time values before leaving the job site • Read and write to specific registers • Set the data scalar setting • Update PowerScout firmware HIGH PERFORMANCE INSTRUMENTS FOR ENERGY MEASUREMENT INDUSTRY’S MOST DEPENDABLE & PRECISE ENERGY MEASUREMENT The PowerScout series networked power meters are designed to provide timely and accurate consumption data to gain the upper hand on electrical costs in today’s escalating energy market. PowerScout meters can capture kWh/kW energy and demand data as well as virtually all relevant energy parameters for diagnostics and monitoring on three-phase or single-phase circuit installations. The PowerScout’s flexibility, size, and ease-of-use make them ideal tools for gathering detailed consumption data in commercial, industrial, government and retail environments. MAXIMUM VERSATILITY & FLEXIBILITY Every PowerScout features field-selectable Modbus or BACnet protocols, interchangeable split-core or flexible RoCoil CTs, and direct USB setup. Connect via RS-485 or optional Ethernet and use the optional back-lit display (PS3037) to verify setup and check real time values. The PowerScout makes over 50 total electrical measurements, including energy and demand. E186827 PowerScout Multi-Circuit Monitor FEATURES ■ PowerScout meters monitor voltage, current, power, energy, and many other electrical parameters on single and three-phase systems. ■ The PowerScout uses either BACnet or Modbus protocol and features digital pulse outputs. Available with Serial-only or with Ethernet. ■ Positive and negative Modbus registers/BACnet objects allow for the PowerScout to be used on net metering projects. ■ Mix-and-match a full range of Split Core or RoCoil™ Rogowski-style CTs ■ PhaseChek™ LED indicators confirm proper CT orientation. ■ Line-Powered*: 80-600V Phase-to-Phase Power Supply. ■ Data updates occur once every second. ■ PS3037: Revenue grade. ANSI C12.20-2010 Class 0.2 ■ PS24: Revenue grade. ANSI C12.20-2010 Class 0.5 ■ PS3037: DIN rail or panel mount ■ PS3037: Optional back-lit display available for verifying setup and checking real time values. ■ UL and CE Mark* APPLICATIONS ■ Tenant Submetering ■ Net Metering *Use on 120/240V, 480/277V, 580/355V, or 380/220V services. 50 or 60 Hz. t PS3037 and PS24D (with enclosure) are UL Listed. PS24N (without enclosure) is UL Recognized. CE Mark on all PS3037 and PS24 Serial models. ■ Data Center Monitoring ■ Commercial ■ Retail ■ Industrial

Open the catalog to page 1

All DENT INSTRUMENTS catalogs and technical brochures

  1. 1000A Clamp

    1 Pages

  2. RoCoil

    1 Pages

  3. RoCoil mV

    1 Pages

  4. RoCoil TCA-5

    1 Pages

  5. 72" RoCoil

    1 Pages