MED 16x1.125 Tubular Frame Solenoid
1 / 4Pages

Catalog excerpts

MED 16x1.125 Tubular Frame Solenoid - 1

MED 16x1.125 Deltrol ^ CONTROL! TUBULAR FRAME SOLENOID Two position linear solenoid with tubular frame construction. Features High performance construction Օ DC solenoids applications only Standard push and pull versions available Օ UL approval on many models Electrical Specifications Coil Voltages 6, 12, 24, 115 VDC Coil Power 8 Watts Continuous, 19 Watts Intermittent, 77 Watts Pulse Coil Termination Wire leads 24 AWG (standard) Duty Cycle Continuous, intermittent and pulse (See standard part numbers on page 4) Coil Treatment Tape Wrapped Insulation Class Class A Rating - 105°C (221°F) Max. Dielectric Strength 30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute Mechanical Specifications Size 1.125" (L) x 01.000" (D) Forces See force curves on page 3 Plunger Diameter 0.4375" Plunger Guide Material Plastic Mounting 0.875" Hex Nut Weight Plunger - 1.05 oz, Total - 4.375 oz Life Expectancy 250,000 Cycles (Dependent on load conditions) Agency Approvals UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S105 All dimensions in Inches Specifications subject to change without notice 1 of 4 Rev 07/07/11 ©2011 Deltrol Controls - A Division of Deltrol Corp. 2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com

Open the catalog to page 1
MED 16x1.125 Tubular Frame Solenoid - 3

MED 16x1.125 Force Curves Deltrol CONTR DC Continuous Duty - 8 Watts % 40 Force Cold ( 00% Voltage 0 Gap 94.1 Oz. I I I Force Hot 100% Voltage 0 Gap 60.5 Oz. /f 20 0,00 0,05 0.10 0.15 0.20 0.25 0.30 0 35 0 40 StroMIn.) DC Intermittent Duty - 19 Watts DC Pulse Duty - 77 Watts Standard intermittent duty cycle at nominal voltage is one (1) minute "ON" and three (3) minutes "OFF". Standard pulse duty cycle is 100 milliseconds "ON" and 900 milliseconds "OFF". Note: Cold Force @ 25°C (77°F) Cold Temperature Hot Force @ 130°C (266°F) Coil Temperature Approx. 36 sq. in. Heat Sink Required...

Open the catalog to page 3
MED 16x1.125 Tubular Frame Solenoid - 4

MED 16x1.125 iD? Deltrol CONTROLS Standard Part Numbers Parts No. Voltage Duty Cycle Power Resistance (Ohms) Operation Typical Force (oz). 100% Voltage, 77°, Stroke @ 0.000" 0.125" 0.250" 0.500" 0.750" 53754-80 6 VDC Continuous 8 Watts 4.7 Pull 94 13 4 0 0 53759-80 6 VDC 4.7 Push 53754-81* 12 VDC 19 Pull 53759-81 12 VDC 19 Push 53754-82* 24 VDC 75 Pull 53759-82 24 VDC 75 Push 53754-84 115VDC 1900 Pull 53759-84 115VDC 1900 Push 53754-86 6 VDC Intermittent 19 Watts 1.9 Pull 126 30 10 0 0 53759-86 6 VDC 1.9 Push 53754-87* 12 VDC 7.5 Pull 53759-87 12 VDC 7.5 Push 53754-88* 24 VDC 30 Pull...

Open the catalog to page 4

All Deltrol Controls catalogs and technical brochures

  1. DSVP40-S

    4 Pages

  2. DSVP10

    5 Pages

  3. Solenoids

    6 Pages

  4. Hose Sets

    3 Pages

  5. Relays

    6 Pages

  6. MED 20x2_0

    3 Pages

  7. DSVP16N

    3 Pages