MED 12x1.500 Deltrol ^ CONTR TUBULAR FRAME SOLENOID Two position linear solenoid with tubular construction. Features High performance construction Օ DC solenoids applications only Standard push and pull versions available Օ UL approval on many models Electrical Specifications Coil Voltages 6, 12, 24, 115 VDC Coil Power 6 Watts Continuous, 15 Watts Intermittent, 58 Watts Pulse Coil Termination Wire leads 24 AWG (standard) Duty Cycle Continuous, intermittent, pulse (see standard part numbers on page 4) Coil Treatment Tape wrapped Insulation Class Class A Rating - 105°C (221°F) Max. Dielectric Strength 30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute Mechanical Specifications Size 1.500" (L) x 00.750" (D) Forces See force curves on page 3 Plunger Diameter 0.3125" Plunger Guide Material Plastic Mounting 0.750" Hex Nut Weight Plunger - 0.75 oz., Total - 2.56 oz. Life Expectancy 250,000 Cycles (Dependent on load conditions) Agency Approvals UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S105 All dimensions in Inches Specifications subject to change without notice 1 of 4 Rev 07/07/11 ©2011 Deltrol Controls - A Division of Deltrol Corp. 2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | [email protected]
Open the catalog to page 1MED 12x1.500 Force Curves Deltrol CONTR DC Continuous Duty - 6 Watts \ i ForceCold 100% Voltage \\ / 0 Gap 38.2 Oz w r- Force Hot100%VoFlage \\ / / OGap 29 4 Oz 1 >.10 0.20 0.30 0.10 0.50 StroKt(ln) DC Intermittent Duty - 15 Watts 0.SC Z 60 0.60 Standard intermittent duty cycle at nominal voltage is one (1) minute "ON" and three (3) minutes "OFF". Standard pulse duty cycle is 100 milliseconds "ON" and 900 milliseconds "OFF" Note: Cold Force @ 25°C (77°F) Cold Temprature Hot Force @ 130°C (266°F) Coil Temperature Approx. 16 sq. in. Heat Sink Required Specifications subject to change without notice 3...
Open the catalog to page 3MED 12x1.500 iD? Deltrol CONTROLS Standard Part Numbers Parts No. Voltage Duty Cycle Power Resistance (Ohms) Operation Typical Force (oz). 100% Voltage, 77° F, Stroke @ 0.000" 0.125" 0.250" 0.500" 0.750" 53751-80 6 VDC Continuous 6 Watts 6.2 Pull 38 7.5 3 1.5 0 53761-80 6 VDC 6.2 Push 53751-81* 12 VDC 25 Pull 53761-81* 12 VDC 25 Push 53751-82* 24 VDC 100 Pull 53761-82* 24 VDC 100 Push 53751-84 115VDC 2500 Pull 53761-84 115VDC 2500 Push 53751-86 6 VDC Intermittent 15 Watts 2.5 Pull 50 20 10 4 0 53761-86 6 VDC 2.5 Push 53751-87* 12 VDC 10 Pull 53761-87* 12 VDC 10 Push 53751-88* 24 VDC 40 Pull 53761-88*...
Open the catalog to page 44 Pages
5 Pages
6 Pages
3 Pages
6 Pages
3 Pages
3 Pages
114 Pages
7 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
6 Pages
4 Pages
6 Pages
5 Pages
6 Pages
3 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
3 Pages
3 Pages
3 Pages
5 Pages
3 Pages
7 Pages
2 Pages
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages