1. Catalogs
  2. Deltrol Controls
  3. 160 SERIES RELAY - GENERAL PURPOSE

160 SERIES RELAY - GENERAL PURPOSE
1 /2Pages

160 SERIES RELAY - GENERAL PURPOSE

160 SERIES RELAY - GENERAL PURPOSE
1 /2Pages

Catalog excerpts

160 SERIES RELAY - GENERAL PURPOSE-1

10 160SERIES 5 AND 13 AMP GENERAL PURPOSE PLUG-IN RELAY FEATURES Class F Coil Insulation System for 155°C Total Temperature Coil Molded in DuPont Rynite® for Environmental Protection Unique Armature Stop Maintains Adjustment Fine Wire Gauge Coils are Skeined for Coil Integrity CONTACT DATA CONFIGURATION: Thru 3PDT MATERIALS: 5 AMP: 1/8" Diameter Moveable Fine Silver 3/16" Diameter Stationary Fine Silver 13 AMP: 3/16" Diameter Moveable Silver Cadmium Oxide 3/16" Diameter Stationary Fine Silver Gold Flash Standard on All Contacts Gold Diffused Available on Special Order – Min. Qty. Req’d. CONTACT RATINGS MODEL POLE UL CONFIGURATION RATINGS 5 amp or 1/8 HP at 120VAC 160/165 thru 3PDT 5 amp or 1/4 HP at 277VAC 2 amp at 600VAC 5 amp at 28VDC 13 amp or 1/3 HP at 120VAC 13 amp or 1/2 HP at 277VAC* 10 amp at 28VDC 161/166 thru 3PDT 1 HP at 277VAC - 3 phase 3 amp or 3/4 HP at 600 VAC 12 FLA, 35 LRA at 15VAC 166E thru 3 amp at 150VDC DPDT 30,000 cycles (wM/Balgonweotut) Form X, Y, 10 amp at 150VDC W, and Z 100,000 cycles MODEL POLE SEMKO CONFIGURATION RATINGS 5 amp at 250VAC 50 Hz AC-1 165 F, P, TM thru 3PDT 5 amp at 28VDC DC-1 2.9 amp at 240VAC 50 Hz AC-3 10 amp at 250VAC 50 Hz AC-1 166 F, P, TM thru 3PDT 10 amp at 28VDC DC-1 4.9 amp at 240VAC 50 Hz AC-3 *3 Pole Devices Rated at 6-2/3 Amp When Switching Greater Than 150VAC, Unless Polarity is the Same on All Poles. UL RECOGNIZED FILE NO.: E37066 US and Canadian Recognition SEMKO CERTIFICATE NO.: 9726189/01-02 Model 165/166 F,P,TM EXPECTED LIFE Electrical At Rated Load (Minimum) 100,000 Operations Except as Noted Mechanical Life 10,000,000 Operations DIELECTRIC STRENGTH 800 VRMS, 60 Hz Between Contacts 2200 VRMS, 60 Hz Between All Other Elements MODELS 160: 5 Amp Open Frame 161: 13 Amp Open Frame 165: 5 Amp Covered Plug-In 166: 13 Amp Covered Plug-In 165F: 5 Amp Flanged Cover w/QC Terminals 166F: 13 Amp Flanged Cover w/QC Terminals 166E: Addition of Blowout Magnets – For Higher DC Ratings Other Suffixes Available A-Indicator Lamp, B-Push to Test Button P-Printed Circuit Terminals, TM-Top Mount Cover COIL DATA NOMINAL RESISTANCE NOMINAL VOLTAGE IN OHMS COIL ± 10% POWER 6VAC 5.0 AC Coils 12VAC 20 Single 24VAC 80 2.0VA Pole Units 48VAC 315 120VAC 2025 240VAC 8000 6VAC 4.5 AC Coils 12VAC 18 2 & 3 24VAC 72 2.2VA Pole Units 48VAC 285 120VAC 1850 240VAC 7200 6VDC 30 DC Coils 12VDC 120 1-3 24VDC 480 1.2W Pole Units 48VDC 1850 110VDC 10,000 Coil Voltages: USA/Canada European AC: Up to 277 Volts/60 Hz AC: Up to 250 Volts 50/60 Hz DC: Up to 125 Volts DC: Up to 125 Volts Coil Treatment: Molded Rynite® Std. Class F Insulation Resistance: 100 Megohms Minimum UL Insulation System File No.: E74443 S155D 155°C Total Temperature Std. (Covers S105 Class A and S130D Class B Requirements) OPERATE DATA Pick Up (at 25°C): AC: Volts 85% or Less of Nominal DC: Volts 75% or Less of Nominal Operate Time: Approx. 15 Milliseconds Release Time: Approx. 15 Milliseconds ENVIRONMENTAL DATA Operating Ambient: AC: -45° to 55°C DC: -45° to 70°C Coil Temperature Rise: (25°C Ambient – Continuous Duty) AC: 45°C Approx. @ 60 Hz – Use at 50 Hz will Cause Slight Increase in Coil Rise DC: 25°C Approx. MECHANICAL DATA Terminals: All Versions (Except P suffix) .187" x .020" Quick Connect/Solder P suffix Version Printed Circuit Pins Cover: Clear Polycarbonate – Flammability Rating 94V2 Weight: Approx. 3 oz. (85 g) 166 161 Semko marked upon request model 165/166 F, P, TM DIVISION OF DELTROL CORP.

 Open the catalog to page 1

All Deltrol Controls catalogs and technical brochures

  1. DSVP40-S

    4  Pages

  2. DSVP10

    5  Pages

  3. Solenoids

    6  Pages

  4. Hose Sets

    3  Pages

  5. Relays

    6  Pages

  6. MED 20x2_0

    3  Pages

  7. DSVP16N

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.