Overview
The NXR-series IO-Link I/O Hub is designed for reduced wiring systems with IO-Link, offering features such as IP67 protection, scalable digital inputs and outputs, and monitoring capabilities for power supply voltage. It is part of a system that includes controllers, EtherNet/IP scanners, and IO-Link Master Units.
System Configuration
The system consists of several components: a Controller, EtherNet/IP Scanner, NXR-series EtherNet/IP IO-Link Master Unit, NXR-series IO-Link I/O Hub, Non-IO-Link Connected External Device, and CX-ConfiguratorFDT software for configuration and monitoring.
Ordering Information
Details on applicable standards, product names, specifications, and model numbers for the IO-Link I/O Hub and Master Unit are provided, along with information on software packages like CX-One and Sysmac Studio.
Cables and Connectors
Specifications for IO-Link cables, I/O cables, and waterproof covers for connectors are detailed, including cable length, connector type, and manufacturer.
General Specifications
The NXR-series IO-Link I/O Hub features IP67 protection, operates in temperatures from -10 to 55°C, and has a vibration resistance of 10 to 60 Hz. It conforms to various international standards, including cULus, EU, KC, and EAC.
Individual Specifications
Specifications for models NXR-ID166C-IL2 and NXR-CD166C-IL2 include power supply requirements, dimensions, and IO-Link communication protocol details.
Mounting and Installation
The hub can be mounted using M5 screws with specific torque requirements and supports multiple installation orientations.
Digital Input and Output
Details on the number of inputs and outputs, response times, and protection features like short-circuit and line disconnection detection are provided.
Version Information
The document outlines the relationship between unit versions of the IO-Link I/O Hub and the EtherNet/IP IO-Link Master Unit, along with the corresponding support software versions.
External Interface
Descriptions of connectors, status indicators, and mounting holes are provided, detailing their functions and specifications.
Dimensions and Wiring Examples
Dimensions are given in millimeters, and wiring examples for two-wire and three-wire sensors, as well as output devices, are illustrated.
Power Supply System
The power supply system for the IO-Link I/O Hubs is explained, including the roles of the Digital Input Hub and Digital I/O Variable Hub in the system.
Specifications
The IO-Link Master Unit and I/O Hub require a 24 VDC power supply and feature multiple I/O connectors for connecting external devices and an IO-Link connector for communication.
Procedures
User manuals provide detailed instructions on hardware setup, configuration, and functionality.
Standards and Trademarks
Various trademarks and standards are mentioned, indicating compatibility and integration capabilities with other industrial systems.
Contact Information
Contact details for OMRON offices in Canada, Mexico, Brazil, and Argentina are provided for customer support and sales inquiries.
Product Range
OMRON offers a wide range of automation products, including controllers, robotics, operator interfaces, motion and drives, vision systems, sensors, safety equipment, control components, switches, relays, and software solutions.
Environmental Note
The document is printed on recycled paper, highlighting OMRON's commitment to environmental sustainability.
See more

Catalog excerpts

Environment-resistive Remote Terminal NXR-series IO-Link I/O Hub NXR-□D166C-IL2-1

Environment-resistive Remote Terminal NXR-series IO-Link I/O Hub Reduced wiring system with IO-Link IP67 protection Scalable digital inputs and outputs via IO-Link master Detection of disconnections or short circuits in I/O cables to connect external devices Monitors power supply voltage for the unit and inputs and power supply voltage for out

 Open the catalog to page 1
Environment-resistive Remote Terminal NXR-series IO-Link I/O Hub NXR-□D166C-IL2-2

D166C-IL2 System Configuration System Configuration *1. For available versions, refer to Version Information on page 9.

 Open the catalog to page 2
Environment-resistive Remote Terminal NXR-series IO-Link I/O Hub NXR-□D166C-IL2-3

D166C-IL2 Ordering Information Applicable standards Refer to the OMRON website (www.ia.omron.com) or ask your OMRON representative for the most recent applicable standards for each model. *1. SYSMAC-SE200D-64 runs on Windows 10 (64 bit). *2. Multi licenses are available for the Sysmac Studio (3, 10, 30, or 50 licenses).

 Open the catalog to page 3
Environment-resistive Remote Terminal NXR-series IO-Link I/O Hub NXR-□D166C-IL2-4

D166C-IL2lO-Link Cables Cables to connect the lO-Link master unit with an M12 plug

 Open the catalog to page 4
Environment-resistive Remote Terminal NXR-series IO-Link I/O Hub NXR-□D166C-IL2-5

General Specifications *1. Refer to the OMRON website (www.ia.omron.com) or ask your OMRON representative for the most recent applicable standards for each model.

 Open the catalog to page 5
Environment-resistive Remote Terminal NXR-series IO-Link I/O Hub NXR-□D166C-IL2-6

Individual Specifications Item Specification Model Device type Unit/input power supply voltage Current consumption from Unit/input power supply Maximum current of Unit/input power supply Output power supply voltage Current consumption from output power supply Maximum current of output power supply 174 × 24.2 × 62 mm (W × H × D) (The height is 37.8 mm when the connectors are included.) Isolation method IO-Link circuits Internal circuits Circuit layout Input circuits Nonisolated power supply circuits IO-Link circuits Input circuits Nonisolated power supply circuits Internal circuits

 Open the catalog to page 6
Environment-resistive Remote Terminal NXR-series IO-Link I/O Hub NXR-□D166C-IL2-8

*1. Detects a short-circuit that occurred between the V and G power supply terminals of the I/O connectors to protect the lO-Link I/O Hubs. *2. Detects a disconnection of the V power supply terminal of the I/O connectors. *3. Detects a short-circuit that occurred between pin 4 and the G power supply terminal and between pin 2 and the G power supply terminal to protect the IO-Link I/O Hubs. *4. Detects a disconnection of pin 4 and pin 2 of the I/O connectors.

 Open the catalog to page 8
Environment-resistive Remote Terminal NXR-series IO-Link I/O Hub NXR-□D166C-IL2-9

Version Information The following table shows the relationship between the unit versions of the lO-Link I/O Hub and NXR-series EtherNet/IP lO-Link Master Unit, and the corresponding support software versions. With the combinations of the versions that are the same as or later (higher) than the versions in the table below, you can use all the functions that are supported by each unit version of the IO-Link I/O Hub.

 Open the catalog to page 9
Environment-resistive Remote Terminal NXR-series IO-Link I/O Hub NXR-□D166C-IL2-10

External Interface —\ omROn Lxr-coibsc-iu —} © IO-Lrk L *1. This is supplied from the lO-Link Master Unit through the lO-Link cable.

 Open the catalog to page 10
Environment-resistive Remote Terminal NXR-series IO-Link I/O Hub NXR-□D166C-IL2-12

Wiring Example for I/O Connectors Wiring Example for Two-wire Sensors A wiring example for a 2-wire sensor to an input of the Digital I/O Hub is given below. In this example, pin 4 of port 1 serves as an input. Two-wire sensor Digital I/O Hub with an input The power to pin 1, or +(V), is supplied from the IO-Link Master Unit through the IO-Link cable to the Digital I/O Hub. Wiring Example for Three-wire Sensors A wiring example for a 3-wire sensor to an input of the Digital I/O Hub is given below. In this example, pin 4 of port 1 serves as an input. Three-wire sensor PNP type Digital I/O Hub...

 Open the catalog to page 12
Environment-resistive Remote Terminal NXR-series IO-Link I/O Hub NXR-□D166C-IL2-13

Power Supply System The following shows the power supply system for the IO-Link I/O Hubs. The Unit/input power and output power are supplied from the IO-Link Master Unit, which is connected to an external power supply, through the IOLink cable to the IO-Link I/O Hub. Digital Input Hub (NXR-ID166C-IL2) The Digital Input Hub does not require the output power to be supplied to the Hub. IO-Link Master Unit Internal circuits Connected external device Internal circuits IO-Link connector Connected external device circuits Power supply connector (input) (PWR IN) IO-Link cable Power supply cable Power...

 Open the catalog to page 13
Environment-resistive Remote Terminal NXR-series IO-Link I/O Hub NXR-□D166C-IL2-14

Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products. Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United Status and/or other countries. EtherCAT® is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. EtherNet/IPTM is a trademark of ODVA. Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.

 Open the catalog to page 14
Environment-resistive Remote Terminal NXR-series IO-Link I/O Hub NXR-□D166C-IL2-15

OMRON AUTOMATION AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • automation.omron.com OMRON CANADA, INC. • HEAD OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • automation.omron.com OMRON ELETRONICA DO BRASIL LTDA • HEAD OFFICE Sao Paulo, SP, Brasil • 55 11 5171-8920 • automation.omron.com OMRON ELECTRONICS DE MEXICO • HEAD OFFICE Ciudad de Mexico • 52.55.5901.4300 • 01.800.386.6766 • [email protected] OMRON ARGENTINA • SALES OFFICE Buenos Aires, Argentina • +54.11.4521.8630 • +54.11.4523.8483 [email protected] OMRON ELECTRONICS DE MEXICO • SALES OFFICE San Pedro Garza...

 Open the catalog to page 15

All Delta Tau catalogs and technical brochures

  1. 3U042

    4  Pages

  2. 3U081

    4  Pages

  3. 3U151

    4  Pages

  4. ACC-8D OPT4

    3  Pages

  5. ACC-8D OPT4A

    3  Pages

  6. PMAC2A PC/104

    6  Pages

  7. POWER UMAC

    4  Pages

  8. TURBO UMAC

    6  Pages

  9. MLDT Sensor

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.