HD32.7-HD32.8.8-HD32.8.16 DATALOGGER - 1

HD 32.7 HD 32.8.8 HD 32.8.16 TECHNICAL SPECIFICATIONS Number of Inputs 8 DIN 45326 8-poles male connectors. 0.01°C (in the range ±199.99°C) 0.1°C in the remaining range Measuring range -200°C … 650°C Display Backlit graphic LCD 128x64 pixel. Keyboard 15 keys, configurable also without PC. Keyboard locking function with password. Memory divided into 64 blocks. Memory capacity 96.000 storages for each one of the inputs. Security of data stored Temperatura °C, °F, °K Resolution 24 1min/month max drift Unit of measurement HD32.7 8 INPUTS DATA LOGGER FOR pt100 SENSOR PROBES The instrument HD32.7 is a robust 8 inputs data logger for Pt100 sensor temperature probes equipped with SICRAM module. 4 wires Pt100 Probe. • Unit of measurement °C, °F, °K configurable. • Flash memory organized in 64 sections with a total capacity of 96.000 acquisitions for each one of the 8 inputs. Storage can be managed in two ways: - when the available memory is full, data are overwritten by starting from the oldest ones (circular memory), - storage stops when the available memory is full. • Simultaneous display of the 8 inputs. • Maximum, minimum or average of the stored values. • Selectable storage interval: 2, 5, 10, 15, 30 seconds, 1, 2, 5, 10, 15, 20, 30 minutes and 1 hour. • Data logging: instantaneous or postponed, with the possibility of selecting the storage start and end. • Data download: RS232C, 1200...38400 baud or USB 1.1 – 2.0. • DeltaLog9 software for data download and processing. • LCD backlit graphic display 128x64 pixel. • Instrument setup through the keyboard; no connection required to the PC. • Security password for keyboard locking. • Power supply: 4 1.5V alkaline C-BABY type batteries or external power supply 12VDC-1A. • Consumption @6VDC: <60μA when the instrument is off <60μA in sleep mode with 8 probes connected <40mA during data logging with 8 probes connected • Use of the HD32.7 data logger: in the field for machine or equipment measurements, plant or machine testing, production check, oven mapping. ±0.01°C ±1digit (in the range ±199.99°C) ±0.1°C ±1digit in the remaining range Internal watch accuracy HD32.7 - HD32.8.8 - HD32.8.16 DATALOGGER Instrument accuracy when storing unlimited Power supply 4 per 1.5V alkaline Batteries type C-BABY External 12Vdc-1A power supply. Connector, external ∅ 5.5mm, internal ∅ 2.1mm. Current consumption @6Vdc Autonomy <60μA when the instrument is off <60μA in sleep mode with 8 probes connected <40mA during data logging with 8 probes connected 200 hours with 7800mAh alkaline batteries and 8 probes connected Data download 12 Vdc 1A RS232C from 1200 to 38400 baud, galvanically isolated. Sub D 9-pole male connector. USB 1.1 – 2.0 galvanically isolated. USB 1.1 - 2.0 RS232C

Open the catalog to page 1
HD32.7-HD32.8.8-HD32.8.16 DATALOGGER - 3

Keyboard locking function Memory Memory capacity with password. divided into 64 blocks up to 800.000 acquisitions to be divided among all the present inputs. For example, when one probe is connected you get 800.000 acquisitions. When 8 probes are connected you get 96.000 acquisitions each probe. Security of data stored Unlimited. Power supply 4 per 1.5V 4 1.5V alkaline C-BABY type batteries External power supply 12VDC-1A. Connector, external ∅ 5.5mm, internal ∅ 2.1mm. ower supply via the PC USB port. P Current consumption @6Vdc <60μA when the instrument is off <60μA in sleep mode with all...

Open the catalog to page 3

All Delta OHM catalogs and technical brochures

  1. HD9120

    4 Pages

  2. HD 32MT.1

    4 Pages

  3. HD2402

    4 Pages

  4. HD2817T...

    5 Pages