Environmental Outdoor DeltaOHM - 1

Environmental Analysis Environmental analysis - HD 9408T BARO, HD9408TR BARO, HD 9908T BARO Barometric transmitters - HD 9408PS 50 Static port - HD 4V8T BARO Barometric transmitter - HD 9008TRR, HD 9009TRR, HD 9007 Temperature and Relative humidity transmitters, protection from solar radiation - HD 48…07T… active, HD 4907T… passive Active and passive temperature transmitter for solar panels - HD 9817T1, HD 9817T2, HD 9817T3, HD 9817 TVS Humidity and Temperature transmitters, analog or digital TS232, USB, RS485 MODBUS-RTU - HD 9006 Aspirated air temperature sensor - LP PYRA 02, LP PYRA 03, LP SILICON PYRA 04, LP PYRA 08, LP PYRA 10, LP PYRA 12, LP PYRA 13 1st class and 2nd class Pyranometers - HD 9906.51 Heating and ventilation unit - LP PYRA 05, LP PYRA 06 1st class and 2nd class Albedometers - LP NET 07, LP NET 14 Net Irradiance Meters - LP PIRG 01 Pyrgeometer - LP PYRHE 16 Pyrheliometer - LP PHOT 02 Photometric Probe - LP UVA 02 UVA Radiometric Probe - LP UVB 02 UVB Radiometric Probe - LP 471 PYRA..., LP 471 Silicon PYRA Pyranometers with SICRAM module - LP PHOT 03, LP RAD 03, LP PAR 03, LP UVA 03, LP UVB 03, LP PHOT 03S Photometric and Radiometric probes with mV or normalized output 4÷20mA or 0÷10V, or RS485 MODBUS-RTU - LP SD18... Sunshine Duration sensor for the measurement of sunshine duration - HD 2003, HD 2003.1 3-axis ultrasonic Anemometer - HD 52.3D... 3-axis ultrasonic Anemometer - HD 2013.2 Rain detector - HD 2013 Rain Gauge - HD 2013-DB Datalogger for Rain Gauge - HD 32MT.1 Meteo Data logger - HD 32.35, HD 32.35FP, HD 32.36, HD 32.36FP Outdoor protection including acquisition system for weather stations - HD 53GSM GSM/GPRS Quadband module - HD 2004.20, HD 2004.22 Tripod for weather stations and holder for solar panel The qualitative level of our instruments is the result of a continuous evolving of the product itself. This way bring to slight differences between what reported on this manual and the instruments you bought. We can not completely exclude the presence of errors for which we apologise. Data, images and descriptions included in this catalogue can not be enforced legally. We reserve the right to perform any modification and correction at any time without notice.

Open the catalog to page 1
Environmental Outdoor DeltaOHM - 2

HD 9408T BARO HD 9408TR BARO HD 9908T BARO HD 9408TR BARO offers superior temperature performance: the internal circuitry allows the sensor to work at constant temperature so that it achieves accurate temperature compensation over the whole range from -40°C to +60°C. HD 9408TR BARO requires a continuous dc power supply and a differential cabling connection to achieve best results. It is available in different output versions: 0÷1 Vdc, 0÷5 Vdc (1÷5 Vdc, 1÷6 Vdc on request). HD 9908T BARO, unlike the other models, is equipped with a display showing the pressure measurements, an analog output...

Open the catalog to page 2
Environmental Outdoor DeltaOHM - 3

POWER SOURCE AND MEASUREMENT DEVICE HD 9408T BARO 4÷20 mA OUTPUT (two wire) Sensor type Piezoresistive diaphragm Measuring range 800 ÷ 1100 mbar / 600 ÷ 1100 mbar on request 0 ÷ 1 Vdc standard; 0 ÷ 20 mA, 4 ÷ 20 mA, 0 ÷ 1 Vdc standard; 0 ÷ 5 Vdc, 1 ÷ 6 Vdc 0 ÷ 1 V and 0 ÷ 5 Vdc, 1 ÷ 5 Vdc 0 ÷ 5 V (0 ÷ 10 V on Analog output and and 1 ÷ 6 Vdc on 4 ÷ 20 mA request), configurable request (two wires) on request by means of a jumper. Display: ± 1 mbar, @20°C Accuracy ± 0.5 mbar, @ 20°C ± 0.5 mbar, @ 20°C Analog output: ± 0,8 mbar, @ 20°C Display: 1 mbar Resolution Infinite Infinite Analog output:...

Open the catalog to page 3
Environmental Outdoor DeltaOHM - 4

The measurement of the barometric pressure in free field can give incorrect values of hundred pascal fluctuation and wind direction. With the static port for barometric measurements, HD9408PS 50 can minimize these errors because, in addition to act as a filter (brake) against the dynamic pressure of the wind, the barometer can operate correctly even in the presence of snow or ice and comply with the recommendations of the WMO (World Meteorological Organization). The materials used for th construction of the static are UV resistant and can operate in temperatures between -40°C and +80°C....

Open the catalog to page 4
Environmental Outdoor DeltaOHM - 5

TESTS MADE IN THE WIND TUNNEL Static port put in front of the wind tunnel Environmental analysis ΔP as a function of speed (yaw angle β = 0°) ΔP as a function of yaw angle (join angle α = 0°) HD 4V8T Baro Barometric transmitter Barometric transmitter to wall mount for indoor use, with 0…1 Vdc analog output. Measuring range 600…1100mbar. Power supply 10…40 Vdc. Working temperature -30°C… 60°C. Suitable for installation in the housings for weather stations HD32.35, HD32.35FP, HD32.36 and HD32.36FP. Speed (m/s) ΔP as a function of speed (join angle α = 0°) Technical specifications Type of...

Open the catalog to page 5
Environmental Outdoor DeltaOHM - 6

An out-of-standard temperature operating range can be requested when placing the order. Important Warning: probes work in the -40°C…+80°C temperature range. Outside this range data are not correct; electronics is designed to operate in this range. SENSORS The humidity sensor is a condenser which dielectric is made up by an hygroscopic polymer. As water dielectric constant is approximately 80, you’ll get a strong change in capacity as the humidity content of this polymer changes. The advantages of this kind of sensor are: good linearity, insensitivity to temperature changes, fast response...

Open the catalog to page 6
Environmental Outdoor DeltaOHM - 7

PROGRAMMING HD9008TRR and HD9009TRR relative RH and temperature transmitters are factory calibrated. The HD9008TRR is provided with a 4…20mA current output, while the HD9009TR with a 0…1Vdc voltage output. In the HD9008TRR standard configuration, 4mA correspond to 0%RH and -40°C, while 20mA equal 100%RH and +80°C. In the HD9009TRR one, 0Vdc corresponds to 0%RH and -40°C, while 1Vdc equals 100%RH and +80°C. The user can re-calibrate the RH probe holding the 0%…100%RH range and setting a different range for temperature, as long as it is within -40 and +80°C limits. Figure 4 shows the...

Open the catalog to page 7