Mobrey MSP-RTP

Mobrey MSP-RTP

Mobrey MSP-RTP

Product catalog summary
Introduction
The Mobrey MSP-RTP External Temperature Sensor is designed for use with ultrasonic transmitters MSP400RH and MSP900GH. It enhances accuracy in installations where the integral temperature sensor does not accurately represent the air or medium temperature.

Sensor Specification
The sensor features a 316 stainless steel body with two locknuts and an M8 thread, suitable for a maximum panel thickness of 6 mm. It operates within a temperature range of -40 to 85 °C, while the cable can withstand temperatures from -20 to 80 °C. The sensor includes a 5-meter long single twisted pair cable. When used with an MSP900GH intrinsically safe transmitter, it is classified as 'simple apparatus' under EN 50020 paragraph 5.4, with a temperature class of T6 and operational range of -20 °C to 80 °C.

Installation Guidelines
1. Connect the sensor wires to terminals 7 and 8 of the transmitter without concern for polarity.
2. Install the sensor between the transmitter and the liquid level to measure temperature at a representative point.
3. Ensure the sensor does not become submerged.
4. Avoid placing the sensor near heat sources or in direct sunlight.
5. Do not mount the sensor directly onto a large thermal mass for optimal temperature response.
6. Prevent false echoes by avoiding direct placement in the transmitter beam path.
7. The transmitter will automatically detect and enable the sensor, with fine adjustments available as per the Installation Manual.

Contact Information
Delta Mobrey Limited, Riverside Business Park, Dogflud Way, Farnham, GU9 7SS, UK. Phone: +44 (0)1252 729140, Email: [email protected].
Standard Terms and Conditions of Sale are available at www.delta-mobrey.com.
See more

Catalog excerpts

Mobrey MSP-RTP-1

Mobrey MSP-RTP External Temperature Sensor Part No : MSP-RTP For use with ultrasonic transmitters MSP400RH and MSP900GH Introduction For transmitter installations where the integral temperature sensor is not representative of the air / medium temperature in the process, the use of the external temperature sensor improves accuracy. Sensor Specification 316 Stainless steel body with two locknuts, M8 thread, 6 mm maximum panel thickness. Sensor working temperature -40 to 85 °C, cable working temperature -20 to 80 °C. Cable 5 m long, single twisted pair. Note: When connected to a MSP900GH intrinsically safe transmitter, this sensor is classif edas'simple apparatus’ according to EN 50020 paragraph 5.4. Temperature class T6, -20 °C < Ta < 80 °C delta mobrey

 Open the catalog to page 1
Mobrey MSP-RTP-2

1. Connect the two sensor wires to terminals 7 and 8 of the transmitter; polarity is not important. See diagram below; also refer to Transmitter Installation Manual. Ensure use of a suitably IP rated cable gland to maintain the IP rating of the transmitter. 2. Mount the sensor between the transmitter and the liquid level, to measure the air / medium temperature at a representative point. 3. Avoid allowing the sensor to become submerged. 4. Do not mount the sensor near a heat source or in direct sunlight. 5. For the optimum response to temperature change, do not mount directly onto a large thermal...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.