D-Series

D-Series

D-Series

Product catalog summary
Technical Datasheet Overview: This document provides detailed specifications and guidelines for the D-Series Flanged Seals with Flush Diaphragm, specifically the S-P models. It includes dimensions, applications, measuring ranges, material specifications, and ordering information.
Specifications: The datasheet outlines the dimensions for various diaphragm seal versions (DN50, DN80, DN100) with details on diaphragm diameter, contact face diameter, bolt circle diameter, external diameter, thickness, and number of holes. Capillary lengths range from 1 to 3 meters, with special versions up to 6 meters.
Applications: The diaphragm seal is used to transmit pressure signals to measuring devices while isolating them from damaging impacts such as extreme temperatures, high viscosity, impurities, and vibrations.
Measuring Ranges: The document specifies recommended minimum measuring ranges for different diaphragm seal types and pressure measuring devices. It also addresses absolute zero error due to ambient temperature fluctuations.
Temperature and Pressure Limits: The temperature range for measured mediums varies based on the type of diaphragm seal and manometric liquid used. Maximum pressure ratings are 40 bar for PN40 and 150 psi for ANSI 150. Materials used include 316L stainless steel.
Recommendations: To minimize thermal zero error, it is advised to use shorter capillaries, larger diameter seals, and place capillaries in areas with minimal temperature fluctuations.
Ordering Information: The document provides a format for ordering, including details on the pressure transmitter, diaphragm seal version, capillary length, and type of manometric liquid.
Contact Information: Delta Controls Limited provides contact details for further inquiries and reserves the right to amend the document without notice.
See more

Catalog excerpts

D-Series-1

Technical Datasheet D-Series Flanged Seals with Flush Diaphragm Remote connection with: smart and analog pressure and differential pressure transmitters DIN 2512 Form N standard contact face (DN50 PN40) Length of cover: 54 mm for capillary £ 3 m 84 mm for capillary > 3 m Capillary from 1 to 3 m (special versions up to 6 m) Direct connection with: smart and analog pressure and differential pressure transmitters

 Open the catalog to page 1
D-Series-2

Application The diaphragm seal is a pressure transmitting, diaphragm-type device. The pressure signal is sent to the cooperating pressure measuring device (pressure transmitter, pressure gauge) through manometric liquid filling the space between the separating diaphragm of the seal and the pressure measuring device. The diaphragm seal task is to isolate the pressure measuring device from damaging impacts caused by either medium or installation: s Low or high temperature, increased viscosity, and impurities s Vibrations of the installation (remote diaphragm seal) Measuring Ranges Recommended minimum...

 Open the catalog to page 2
D-Series-3

Diaphragm seal version Capillary length Type of manometric liquid – DC (high-temperature), AK (low-temperature) Example: DPCE-28 pressure transmitter, EEx version, measuring range 0 ÷ 1 bar, cable connection, direct flanged seal with flush diaphragm DPCE-28 / EEx / 0 ÷ 1 bar / PK /

 Open the catalog to page 3
D-Series-4

In the interest of development and improvement Delta Controls Ltd, reserves the right to amend, without notice, details contained in this publication. No legal liability will be accepted by Delta Controls Ltd for any errors, omissions or amendme nts. Delta Controls Limited Island Farm Avenue, West Molesey, Surrey KT8 2UZ, UK. T+44 (0)20 8939 3500 F+44 (0)20 8783 1163 E [email protected] W www.delta-controls.com

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.