Technical Datasheet Pressure Transmitter: Analogue Series 387  High Accuracy ± 0.15%.  Ranges from 1 bar to 1000 bar.  4 : 1 turndown.  4-20mA analogue with digital communications.  316 stainless steel investment Cast Enclosure.  NEMA 4X, IP66 weatherproof rating.  Stainless Steel and Hastelloy “Wetted Parts” options.  NACE MR-01-75 compatibility.  All welded construction. Performance characteristics Enclosure options  Weatherproof IP66 Protection – NEMA 4X  Intrinsically safe – EExia ATEX  Flameproof – EExd ATEX Product applications Wetted parts options  Welded 316 stainless steel sensor and process connection.  Welded Nickel Alloy (Monel) sensor and process connection.  Welded Hastelloy sensor and process connection. Signal output  Refer to table 6. The 387 is suitable for a wide range of applications in many Industry sectors:  Oil & Gas  Chemical  Petrochemical  Water  Power The choice of models available ensures Process connection  ½” NPT External that the 387 is:  Suitable for use in corrosive atmospheres  G ½” A to ISO 228 (1/2” BSP Parallel Male, spigotted).  Resistant to chemical attack  High pressure cone and thread (autoclave) 9/16” UNF. How can we help you? Unit weight Delta Controls’ range of reliable pressure and temperature measurement instruments can be customised to meet individual requirements. For technical advice or to discuss your application,

Open the catalog to page 1
Analogue  Series 387 - 2

Enclosures FINISH All enclosures are investment cast in 316 Stainless Steel and offer environmental protection to (NEMA TYPE 4X) IP66. NOTE: Instruments subject to National or International approval may be limited in terms of options available. See notes adjacent to relevant tables. TABLE 1 Code Intrinsically Safe to EN60079-0; 60079-11, 60079-26 Ex ia IIC T4 (Tamb= -20°C to +90°C) Ex ia IIC T5 (Tamb= -20°C to +40°C) Flameproof to EN60079-0, 60079-1, 61241-0, 61241-1 Code Single Pressure transmitter Electrical Entry M20 x 1.5 (ISO) and 1/2” NPT Internal threads available as standard. Other...

Open the catalog to page 2
Analogue  Series 387 - 3

Setting Ranges The values shown in this table are the UPPER RANGE LIMIT (URL); a 4:1 turndown facility enables full 4 to 20mA output to be obtained for a working span equal to 25% of URL. Unless specified, the instruments are despatched with LOWER RANGE VALUE (LRV) set to zero and UPPER RANGE VALUE (URV) set to URL. Medium Pressure Material Code “R” only. (Table 4) Accuracy ±0.15% Maximum working pressure Pmax 2 x URL. TABLE 5 Ranges shown are to gauge (i.e. atmospheric reference; absolute pressure is called up by amending the last character of the three character range code: Bar/mbar...

Open the catalog to page 3
Analogue  Series 387 - 4

Signal Output All 4-20mA. Code M is only available with wetted part material codes C or U. Ref Table 4. Process Connection Other thread specifications and sizes are available without using adaptors. Adaptors are available for applications where their use is permitted. Options and Treatments For requirements that fall outside the specifications listed above we will be pleased to advise on your particular application. Code 4 to 20mA, 2-wire system. 4mA equivalent to nominal zero input pressure. Span of unit adjustable so that 20mA may be equivalent to any pressure between 25% and 100% of...

Open the catalog to page 4
Analogue  Series 387 - 5

Technical Specifications OUTPUT 4 to 20mA proportional to pressure, 2-wire POWER SUPPLY 12 to 38V DC at instrument terminals. Reverse polarity protected. Less than 0.01% per volt effect. ACCURACY Less than ±0.15% of URV*, including combined effects of linearity, hysteresis and repeatability LONG TERM STABILITY Less than ±0.15% of URL*, over a 6 month period. AMBIENT TEMPERATURE -20 to +85°C (-4 to +185°F) PROCESS TEMPERATURE -40 to +120°C (-40 to +240°F) AMBIENT TEMPERATURE Less than ±0.025% of URL*, for every 1 deg C (1.8 deg F) change in ambient temperature. VIBRATION TOLERANCE 5g peak to...

Open the catalog to page 5
Analogue  Series 387 - 6

CENELEC/BASEEFA (EECS) CENELEC/BASEEFA Intrinsically Safe. BASEEFA certified to CENELEC EN 50 014 and EN50 020 for use in Zone 1 hazardous areas. Enclosure Codes 4 and all ranges. Flameproof / Weatherproof BASEEFA certified to CENELEC EN 50 014 and EN50 018 for use in Zone 1 hazardous areas. Certificate No ITS03ATEX21062X System Certificate Enclosure Code R and all ranges 10 bar (160 psi) and above. FACTORY MUTUAL RESEARCH CORPORATION FM Approved for use in Divisions 1 and 2. Enclosure Code F; see Table 5 for limitations on ranges. File number 4V3A8.AX & 2X6A6.AX WALL MOUNTING BRACKET 100g...

Open the catalog to page 6

All Delta Mobrey Limited catalogs and technical brochures

  1. GG

    9 Pages

  2. 200 Series

    8 Pages

  3. GR Series

    8 Pages

  4. DPR-2000G

    4 Pages

  5. DPR-2200

    8 Pages

  6. D-Series

    4 Pages

  7. Smart 2HT

    17 Pages

  8. GB

    7 Pages

  9. DG Range

    6 Pages

  10. GS Range

    6 Pages

  11. RTD

    16 Pages