8000 SAN Series
6Pages

{{requestButtons}}

Catalog excerpts

8000 SAN Series - 1

Technical Datasheet Hygenic / Sanitary Pressure-Level Transmitters: 8000 SAN Series • Stainless Steel Housing. • Accuracy 0.2% from adjusted span. • Active Temperature Compensation. • Zero / Span internally adjustable. • Strong flush diaphragms. • Many process connections. • ATEX EEx ia. Perf ormance characteristics Enclosure / Housing • Robust stainless steel 304. Protection to IP65. Process connections • Diary fitting to DIN 11851. Product applications • Hygenic Weld Fitting. The 8000 SAN is suitable for a wide range • Tri-clamp connection. of applications in many Industry sectors: • Food and Beverage • Water • ANSI Flange 150# Options • Standard enclosure. • Sanitary • Hygenic • Integral Digital Indicator. Ranges • From 0 up to 16 bar, with max overpressure of 60 bar. Accuracy The choice of models available ensures that the 8000 SAN is suitable for use in: • Corrosive atmospheres • Resistant to chemical attack How can we help you? Delta Controls’ range of reliable pressure and temperature measurement instruments can be customised to meet individual requirements. For technical advice or to discuss your application, please contact us on +44

Open the catalog to page 1
8000 SAN Series - 2

Process Connections Options Overview Code M milk coupling 1”, 1 ½”, 2” (NW25, 40, 50) DIN11851. Series 8000-SAN-RANGE-M offers a choice of diary fittings. The 1” (NW25) version has an extra tough diaphragm specially developed for pressure measurement in the food and pharmaceutical industries. 1” (NW25) 1 ½” & 2” (NW40/50) NOTE: 2” S.M.S., I.D.F. = APV/RJT fittings are also available. Code W Sanitary weld-on nipple 62mm or 85mm O.D. The ideal connection for level measurement. The nipple is directly welded to the tank, the transmitter being engaged by means of a locking ring. This provides a...

Open the catalog to page 2
8000 SAN Series - 3

Code F Flange Connection 1 ½”, 2” & 3”. This design utilizes the same weld-on fitting as Code W factory welded to the process flange. This allows easy removal of the transmitter. All standard flanges are available to DIN PN10/16 (NW40/50 & 80) and ANSI 150LB (1 ½”, 2” & 3”). Other standards are available to special order. Range / Connection Options 8000 SAN Cable This version offers separate electronics and measuring sensor for applications where remote mounting is desirable, i.e underground storage tanks. The sensor is fully potted and offers protection against full immersion up to 100...

Open the catalog to page 3
8000 SAN Series - 4

Parts Description: 1. Cover st st 304 2. O-ring EPDM 3. Vent 4. Cable entry 5. Electr. Compartment st st 304 6. Connecting part st st 304 7. Diaphragm ring st st 316 8. Lockring st st 304 9. Weld-on nipple/flange st st 316 10. Packing ring PTFE Ordering Code Model Number Unless otherwise specified all instruments are despatched with range set to maximum span Process Connections Diary fitting to DIN 11851 Hygenic Weld fitting Tri-clamp Connection ANSI Flange 150# Special Size NW25 Code M25 Size Plain 62mm Code W Size 1” Code L10 Size 1” Code F10 Specify in full OPTIONS Standard Enclosure...

Open the catalog to page 4
8000 SAN Series - 5

Performance Data Measuring Ranges (Optional) Vacuum, compound & special high ranges. Output Signal : 4 to 20mA proportional to pressure/level 2 wire system Power Supply Permissible Load Electrical Connection : Standard PG9 or ½” NPT (please specify) Process Temperature : Standard –30 to + 100°C (max to 150°C for max 45 mins permissible) Ambient Temperature Temperature Effect : Robust st.st 304. Protection to IP65. Alternative materials. Wetted parts : AISI 316 laser welded diaphragm. PTFE seals. Hastelloy B & C, Ceramic possible. : Fitted with RFI filters as standard and in accordance with...

Open the catalog to page 5
8000 SAN Series - 6

Indicator Options Integral 3 V* digit LCD indicator Please state unit of measurement and calibration required when Remote Indicator (Panel or Wall Mounting} MAINS IKPUT Supply wire loop) Please specify requirements to enable us to offer suitable indicator. Options with alarms and linearization for irregular shaped tank contents measurements are available. In the interest of development and improvement Delta Controls Ltd, reserves the right to amend, without notice, details contained in this publication. No legal liability will be accepted by Delta Controls Ltd for any errors, omissions...

Open the catalog to page 6

All Delta Mobrey Limited catalogs and technical brochures

  1. GG

    9 Pages

  2. 200 Series

    8 Pages

  3. GR Series

    8 Pages

  4. DPR-2000G

    4 Pages

  5. DPR-2200

    8 Pages

  6. D-Series

    4 Pages

  7. Smart 2HT

    17 Pages

  8. GB

    7 Pages

  9. DG Range

    6 Pages

  10. GS Range

    6 Pages

  11. RTD

    16 Pages