SM15K series
1 /6Pages

SM15K series

SM15K series
1 /6Pages

Catalog excerpts

SM15K series-1

Vissersdijk 4, 4301 ND Zierikzee, the Netherlands SM15K - Series 15kW DC POWER SUPPLIES Bi-Directional - Constant Power Models Voltage range Current range Bi-Directional power supply, standard 15kW Source & Sink Operation on a wide range of three phase AC input voltages Flexible output with constant power characteristic Standard Ethernet & Web interface Power Regeneration Technology: sink power is not dissipated but fed back into the grid EMC surpasses CE requirements: low emission & high immunity Designed for long life at continuous full power Low audible noise: temperature controlled cooling fans Excellent dynamic response to load changes, digital controlled with the possibility to adapt to the type of load Durable digital encoders for voltage & current adjustment and menu operation Very low heat dissipation, efficiency 95% or more Large user display, menu driven operations Protected against all overlo

 Open the catalog to page 1
SM15K series-2

Absolute maximum Sink voltage DC Power terminals voltage range current range Warning! Higher voltages will damage the unit! Minimum Sink Voltage @ var. sink current: Note that unit switches automatically between Source <-> Sink. AC Input 3 phase, 48 - 62 Hz rated voltage range rated frequency rated current current (400 V / 3 ph, 15kW) power factor, 15kW, 7.5kW internal fuses standby input power (Vo=Io=0) standby input power (Vo=Vmax) Efficiency (Sink & Source mode): 400 V AC, 3 ph input, 15 kW, Iout=100% 15 kW, Uout=100% Regulation Load 0 - 100% CV Line 342 - 528 V AC CV (external voltage sense)...

 Open the catalog to page 2
SM15K series-3

Rise time (10 - 90%) output voltage step time, (load = 15 kW) time, (load = 1500 W) output voltage step time, (load = 15 kW) time, (load = 1500 W) Fall time (90 - 10%) output voltage step time, (load = 15 kW) time, (load = 1500 W) output voltage step time, (load = 15 kW) time, (load = 1500 W) Note: Values on resistive load, unit in CV-mode. With other load, or in CC-mode, values can be longer. DC Output Capacitance X-capacitors (typical) Y-capacitors (typical) Recovery time output voltage recovery within di/dt of load step time, @ 50 - 100% load step max. deviation output voltage recovery within...

 Open the catalog to page 3
SM15K series-4

Series operation max. total voltage Master / Slave operation *) units delivered before Q4 / 2018 **) units delivered Q4 / 2018 or newer Contact factory for upgrading to enable 1000V series operation for older units. Parallel operation Master / Slave operation Remote sensing max. voltage drop per load lead Limits Voltage Current Power Voltage Voltage maximum 60 units default 1 V, can be set to 10 V adjust range adjust range adjust range OverLoad level Self-Protection level 0 - 101 % 0 - 101 % 0 - 101 % 102.5 % - unit will continue to operate (OL-indication in display) 105 % - output is automatically...

 Open the catalog to page 4
SM15K series-5

Solar inverter testing, PV-Simulation Automotive battery simulations Driving PWM-Controlled DC motors Controlled battery (dis)charging Accurate current sources ATE in industrial production lines Aerospace and military equipment Plasma chambers Sustainable energy Standard Features Bi-Directional Two-Quadrant Output Full power Bi-Directional two quadrant operation maintains the DC output voltage constant whether the output power is positive or negative. Ideal for PWM-speed controlled DC-Motors and ATE systems. High Voltage Isolation A high DC output isolation allows floating operation up to 1000...

 Open the catalog to page 5
SM15K series-6

NO Line Cord supplied Optional Interfaces (4pcs) Isolated Analog, RS485 / RS422 / RS232, USB, Digital I/O, Isolated Contacts and M/S-2 Controller. AC Mains Connector (contra-plug supplied) Sense Block USB type-B, Ethernet, Interlock, USB type-A Feet are not mounted but included in packing Safety Covers supplied for in- and output (not shown)

 Open the catalog to page 6