SM 800 - Series

SM 800 - Series

SM 800 - Series

Product catalog summary
Overview: The document provides detailed specifications and features of the SM800 series DC power supplies by Delta Elektronika. These power supplies are designed for long life at full power, excellent dynamic response, and protection against overload and short circuit conditions. They surpass CE requirements for EMC, have low audible noise, and offer various options for customization.
Specifications:
  • Models and Output: The series includes models SM 7.5-80, SM 18-50, SM 70-AR-24, and SM 400-AR-4, each with specific voltage and current ranges. Autoranging is available for certain models.
  • Input: AC single phase, 48-62 Hz, with power derating based on input voltage. Efficiency ranges from 80% to 89% depending on the model and input conditions.
  • Regulation and Ripple: Load and line regulation are specified, with ripple and noise levels detailed for both constant voltage (CV) and constant current (CC) modes.
  • Programming and Monitoring: Analog programming inputs and monitoring outputs are available, with specified accuracy and temperature coefficients.
  • Safety and EMC: Compliance with EN 60950 / EN 61010 for safety and EN 61204-3 for EMC standards.
  • Environmental Conditions: Operating temperature range is -20 to +50°C, with derating at higher temperatures. Humidity and storage temperature specifications are also provided.
Features:
  • Options for high-speed programming, extra isolation, sequencer, digital encoders, and power sink.
  • Master/slave parallel and series operation with voltage and current sharing.
  • Remote sensing and interlock capabilities.
  • 19" rack mounting or laboratory use with included feet.
Applications: The power supplies are suitable for applications such as accurate current sources, automotive battery simulation, driving PWM-controlled DC motors, electronic circuit development, and more.
Available Options:
  • High-speed programming for faster response times.
  • Two-quadrant output for maintaining constant voltage regardless of power direction.
  • Sequencer for arbitrary waveform generation.
  • High voltage isolation for series operation up to 1000V.
  • Software control interfaces including ISO AMP, RS232, IEEE488, Ethernet, PROFIBUS, and CANBUS.
See more

Catalog excerpts

SM 800 - Series-1

Voltage range Current range SM 7.5-80 SM 18-50 SM 70-AR-24 Autoranging output SM 400-AR-4 Autoranging output Designed for long life at full power Master/Slave parallel and series operation with voltage and current sharing Excellent dynamic response to load changes Protected against all overload and short circuit conditions Stacking is allowed, space between units is not required EMC surpasses CE requirements: low emission & high immunity High power system configuration from multiple units Low audible noise: fans are temperature controlled 19" rack mounting or for laboratory use (feet included) Remote sensing Available options: High Speed Programming, Interfaces, Extra Isolation, Sequencer, Digital Encoders, Power Sink etc.

 Open the catalog to page 1
SM 800 - Series-2

AUTORANGING (2 ranges) max. output current / voltage Input AC single phase, 48 - 62 Hz Output voltage current Power Derating vs input: 90 V : Pout max (W), Iin (A) 100 V : Pout max (W), Iin (A) 110 V : Pout max (W), Iin (A) power factor, 100%, 50% load internal fuses standby input power (Vo=Io=0) standby input power (Vo=Vmax) Efficiency AC 230 V input, full load AC 115 V input, max. load Load 0 - 100% CV Line 120 - 265 V AC CV (measured on sense block) Load 0 - 100% CC Line 120 - 265 V AC CC (internal voltage sense) Ripple + noise rms (BW=300 kHz) p-p (BW=20 MHz) rms (BW=300 kHz) p-p (BW=20 MHz)...

 Open the catalog to page 2
SM 800 - Series-3

both NO and NC contact both NO and NC contact Status outputs CC - status LIM- status OT - status PSOL - status ACF - status DCF - status CC - operation CV- or CC-limit Over Temperature Power Sink Overload AC - Fail DC - Fail 2) 5 V = logic 1 5 V = logic 1 5 V = logic 1 5 V = logic 1 5 V = logic 1 5 V = logic 1 ) output voltage ± 5% beyond set point ) output voltage ± 5% beyond set point with + 5V, 1 mA or relay contact Remote ShutDown contact at rear panel, see photo of rear panel on page 1-6 Interlock Indicators (front panel) Voltage meter, Ampere meter, AC-Fail, DC-Fail, Over Temperature, Power...

 Open the catalog to page 3
SM 800 - Series-4

Insulation input / output creepage / clearance input / case output / case Power Supply Standard EN 61204-3, Emission: residential, light industrial environment (CISPR22-Class B) Immunity: industrial environment Generic Emission Generic Immunity EN 61000-6-3, residential, light industrial environment (EN 55022 B) EN 61000-6-2, industrial environment − 20 to + 50 °C derate output to 75% at 60 °C Operating Temperature at full load Storage temperature Output shuts down in case of insufficient cooling Thermal protection MTBF Hold-Up time Vout = 100%, Pout <= 840 W Vout = 85%, Iout = 100% Vout = 100%,...

 Open the catalog to page 4
SM 800 - Series-5

Typical Applications • • • • Accurate current sources Electronic circuit development Component device testing ATE in industrial production lines • Automotive battery simulation • Controlled battery (dis)charging • Lasers • Driving PWM-controlled DC-motors • Medical research equipment • Aerospace and military equipment Available Options High speed programming Increased Output Power Two-Quadrant Output: Power sink The conservatively rated unit allows to deliver extra output with the same reliability. At some derating, either the maximum output voltage or the maximum output current can be increased...

 Open the catalog to page 5
SM 800 - Series-6

Analog (standard) Master / Slave Input Connector Connections programming 50 Hz, unless otherwise noted. The information in this document is subject to change without notice 19" Rack Adapter RA19-2 SM800 Front Panel connection