DVP-ES2
14Pages

{{requestButtons}}

Catalog excerpts

DVP-ES2 - 1

IABU Headquarters 31-1, Xingbang Road, Guishan Industrial Zone, Taoyuan County 33370, Taiwan, R.O.C. Delta Electronics (Jiang Su) Ltd. 1688 Jiangxing East Road, Wujiang Economy Development Zone, Wujiang City, Jiang Su Province, People's Republic of China (Post code: 215200) Delta Greentech (China) Co., Ltd. 238 Min-Xia Road, Cao-Lu Industry Zone.Pudong, Shanghai, People's Republic of China Delta Electronics (Japan), Inc. Tokyo Office Delta Shibadaimon Building, 2-1-14 Shibadaimon, Minato-Ku, Tokyo, 105-0012, Delta Electronics (Korea), Inc. 234-9, Duck Soo Building 7F, Nonhyun-Dong, Kangnam-Gu, Seoul, Korea 135-010 Delta Electronics (Singapore) Pte. Ltd. 8 Kaki Bukit Road 2, #04-18 Ruby Warehouse Complex, Delta Power Solutions (India) Pte. Ltd. Delta Products Corporation (USA) Raleigh Office Research Triangle Park, NC 27709, U.S.A. Delta Products Corporation (Brazil) Rua Itapeva N° 26, 3° andar, Bela Vista Eindhoven Office De Witbogt 15, 5652 AG Eindhoven, The Netherlands *We reserve the right to change the information in this catalogue without prior notice

Open the catalog to page 1
DVP-ES2 - 2

8 points of digital input 8 points of digital output 8 points of digital input, 4 points of analog input 6 points of digital output, 2 points of analog output 16 points of digital input 8 points of digital output 16 points of digital input 16 points of digital output 24 points of digital input 16 points of digital output 36 points of digital input 24 points of digital output 4 points of analog Input, 2 points 16k steps: Large program programmable control

Open the catalog to page 2
DVP-ES2 - 3

Input terminals Main Processing RS-485 COM port terminals Digital Input Module Digital Output Module Digital I/O Module Temperature Measurement Digital Input Modules e Digital Output Modules Temperature Measurement Modu ^^^^^^^^ ^^^^^^^^ iiiiiiiiiii amm.ii iiiiiiiini

Open the catalog to page 3
DVP-ES2 - 4

Model name High-speed input Pulse output External input Servo drive control commands Extension module Motion control execution speed Program capacity block editing 2 points of 100kHz; 6 points of 10kHz; Max. 8 points for single-phase input; Connectable to 8 analog extension modules Yes, with S-curve acceleration/deceleration function Execution speed of basic instructions: 0.35 ~ 1 us Restriction on incorrect password entry, subroutine password and PLC ID 256 input points + 16 output points, or 256 output points + 16 input points Enhanced Program Execution Speed % Enhanced Extension I/O...

Open the catalog to page 4
DVP-ES2 - 5

High-Speed Input DVP-ES2 is built-in with 8 points of high-speed input (2 points of 100kHz, 6 points of 10kHz) and supports U/D, U/D Dir and A/B counting modes. Counting pulse Set up A/B counting mode to double frequency or 4 times frequency in Counting diagram Hardware High-Speed Counters High-speed input Motion control Pulse Output DVP-ES2 is built-in with 4 axes of pulse output (2 points of 100kHz, 2 points of 10kHz) and supports Pulse, Pulse/Dir, A/B and CW/CCW modes. High-Speed Comparison Interruption Use DHSCS or DHSCR high-speed comparison instructions to achieve real-time...

Open the catalog to page 5
DVP-ES2 - 6

Built-in 3 Serial COM Ports DVP-ES2 is built-in with 1 RS-232 port and 2 RS-485 ports. The ports can operate together. DVP-ES2 can be Master or Slave and supports Delta Q-Link protocol to enhance the speed of HMI screen display. The 3 serial ports built in DVP-ES2 are able to construct a complex multi-layer network structure, increasing Built-in Analog I/O in 20EX2 Models 4 analog input point Liquid level Liquid level 2 analog output points! drive control Valve openness Motion Control Instructions & Variable High-Speed Pulse Output Variable Variable speed speed % Immediate Frequency Change...

Open the catalog to page 6
DVP-ES2 - 7

% Close Loop Positioning The close loop positioning instruction compares the encoder feedback signal with the PLC pulse output instruction and decides whether to set up the same number of output pulses. Compensation will be made if difference occurs to ensure correct number of output pulses. # Absolute/Relative Positioning Delta's AC Motor Drive / Servo Drive Analog signal Analog signal DVP-ES2 is able to control AC motor drive or Servo drive through output current and analog voltage signals output from the analog module. DVP-ES2 has new instructions designed particularly for the...

Open the catalog to page 7
DVP-ES2 - 8

Password Protection subroutine password and main password entry times Program designer User B reads the^ This function allows only acquire program The subroutine password and ID can be 4 ~ 8 digits. Enter Program ID (d~S Cliarattera) The number of allowed incorrect entries of main password can be set up. Enhanced Instruction Application SPA & GPS support solar tracker The 2 instructions working with GPS can effectively achieve the highest efficiency Single-axis solar tracking Fixed mode SPD able to detect 4 input points synchronously Use 4 SPD instructions in the program at the same time,...

Open the catalog to page 8
DVP-ES2 - 9

The New Programming Software: ISPSoft The New Programming Software: ISPSoft supports ladder diagram, function block and many other programming modes and is able to edit program in modular way. ISPSoft saves your time in developing large projects. Use the already made function block over and over again to increase your economical benefit. ISPSoft is compatible with all DVP series PLCs. Task Designation The entire program is divided into many program units (POU), including programs and function blocks. The compiled POU can only be operated under designated condition (TASK) to To create new...

Open the catalog to page 9
DVP-ES2 - 10

The New Programming Software: ISPSoft Function Block Import/Export Variable Declaration Seta Nothing Passu™! CbrJiimati™ Password Protection The user can set up password for each function block. When the block is used in other programs, the password is required to open the editing window of the block. Global variable: Separate form the program. The corresponding physical I/O point of the variable is defined only after the program is compiled. The user does not need to modify the program when the definition of the physical I/O point is changed. Only the device correspoinding to the variable...

Open the catalog to page 10
DVP-ES2 - 11

Devices, Electrical Specifications £ I/O Configuration for Digital Modules *1: R refers to relay output; T refers to transistor output (channel N); S refers to transistor output (channel P). For exact launch dates of these models, consult Delta's sales representatives. *2: DVP60ES2 starts input from X50 (output from Y30) and DVP40ES2 from X30 (output from Y20). All other models start input from X20 and output from Y20. The number of extension I/O increases by 8's multiple. Number less than 8 points are regarded as 8 points. *3: I/O points less than 8 points are regarded as 8 points. % I/O...

Open the catalog to page 11

All Delta Electronics catalogs and technical brochures

  1. DPS - 12FP A

    3 Pages

  2. Delta MVD 1000

    20 Pages

  3. Delta MVD2000

    11 Pages

  4. DPS -24GP A

    3 Pages

  5. DVS

    8 Pages

  6. CTA

    2 Pages

  7. DOP-B

    20 Pages

  8. DOP-A

    12 Pages

  9. ASDA-A2

    72 Pages

  10. Linear Motor

    1 Pages