  • Input: Voltage range of 90~264Vac with auto range, frequency between 47~63Hz.
  • Efficiency: Average efficiency of ≥ 87% at 25%, 50%, 75%, and 100% load.
  • Input Current: ≤ 1.2A for 90~132Vac and ≤ 0.6A for 180~264Vac at 12V/3.33A load.
  • Output: 12V with a current range from 0A to 3.33A.
Protection
  • Over-current: Auto recovery.
  • Over-temperature: Latch.
  • Short: Auto recovery.
  • Over-voltage: Auto recovery.
Environment
  • Operating temperature: 0 to 50°C at full load, 60°C at 80% load, 70°C at 60% load.
  • Storage temperature: -20 to 70°C.
  • Operating humidity: 10% - 90%.
  • Storage humidity: 10% - 95%.
Features
  • Total power: 40W.
  • High reliability: >100,000 hours at full load and normal input (25°C).
  • Protection includes short, over-current, over-voltage, and over-temperature.
  • Safety certifications: UL/cUL, TUV, CB by Demko, CCC.
  • EMI: CLASS B.
  • Dimensions: 50(W) x 28(H) x 95(L) mm.
Safety Standards/Directives
  • Electrical Safety: UL/cUL, TUV, CB, CCC, CE, BSMI, referring to EN 60950-1.
  • CE: Conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC.
EMC
  • EMI: Refer to CISPR 22, FCC, VCCI: CLASS B.
  • ESD (IEC61000-4-2): Air Discharge: ±8KV min, Contact Discharge: ±4KV min.
  • EFT (IEC61000-4-4): ±2KV.
  • Surge (IEC61000-4-5): Common Mode: ±4KV, Different Mode: ±2KV.
  • Isolation: Input to Output 3.0KVac.
See more

Catalog excerpts

DPS - 40AP - 10 A-1

• 90-264Vac auto range input • High reliability: > 100,000 hours @ full load • Protection: Short / Over-current / Over-voltage • Safety: UL/cUL, TUV, CB by Demko ,CCC 3, TUNG YUAN ROAD, CHUNGLI INDUSTRIAL ZONE TAOYUAN SHIEH, TAIWAN, R.O.C. DELTA PRODUCTS CORPORATION DELTA ELECTRONICS, EUROPE LTD. 2 YOUNG PLACE KELVIN INDUSTRIAL ESTATE EAST KILBROIDE,

 Open the catalog to page 1
DPS - 40AP - 10 A-2

Electrical Safety UL/cUL, TUV, CB,CCC,CE, BSMI In conformance with EMC Directive 2004/108/EC and Low Voltage EMI: refer to CISPR 22 ,FCC ,VCCI:CLASS B 3, TUNG YUAN ROAD, CHUNGLI INDUSTRIAL ZONE TAOYUAN SHIEH, TAIWAN, R.O.C. DELTA PRODUCTS CORPORATION DELTA ELECTRONICS, EUROPE LTD. 2 YOUNG PLACE KELVIN INDUSTRIAL ESTATE EAST KILBROIDE,