video corpo

Delphi Low Pressure Sensors
3Pages

{{requestButtons}}

Catalog excerpts

Delphi Low Pressure Sensors - 1

Delphi Low Pressure Sensors Delphi Low Pressure Sensors provide precise measurements of operating pressure in the following ranges: • • • • From -0.54 psig to 0.18 psig (-3.75 kPa to 1.25 kPa gauge) From -0.58 psig to 0.58 psig (-4.0 kPa to 4.0 kPa gauge) From -0.97 psig to 0.97 psig (-6.67 kPa to 6.67 kPa gauge) From 0 psig to 2.5 psig (0 kPa to 17.24 kPa gauge) Delphi Low Pressure Sensors are designed to perform in harsh environments such as extreme temperatures and vibration, thermal and mechanical shock, and chemical contamination. They provide voltage output proportional to the gauge pressure in low pressure systems. Electronic compensation for precise measurements in a variety of environments Reliable and robust: o Low part count o Automotive grade o ISO/TS 16949 certified Mounting flexibility Designed for under-hood and fuel tank environments Appropriate for a wide range of automotive and non-automotive applications Patented direct mount eliminates need for bracket Temperature compensation Electromagnetic interference (EMI) protection All-silicon technology Electronically programmable trim to customer specification Delphi Low Pressure Sensors Typical Applications Delphi Low Pressure Sensors can be used in fuel vapor and air filter pressure measurement applications. They can also be used for bladder-type occupant sensing applications in vehicle seating programs. Delphi Low Pressure Sensors can also be used in other nonautomotive filtering applications, such as HVAC and fluid-level sensing in home appliances. www.delphi.com | © Delphi. All rights reserved. | Delphi Low Pressure Sensors offer compact size to help meet packaging objectives. They also feature a direct mounting capability to eliminate the need for separate mounting brackets.

Open the catalog to page 1
Delphi Low Pressure Sensors - 2

Delphi Low Pressure Sensors ► Performance Data for Standard Calibration Note: Custom calibrations are available upon request. ► Temperature Error Multiplier Delphi Low Pressure Sensors offer application flexibility, however, atypical sensor voltage output over a low pressure range is shown in this chart. Available in positive or negative slope output. This graph shows the temperature multiplier to the allowable pressure error over the operating temperature range for Delphi Low Pressure Sensors. www.delphi.com | © Delphi. All rights reserved. |

Open the catalog to page 2
Delphi Low Pressure Sensors - 3

Delphi Low Pressure Sensors ► Allowable Pressure Error The total output pressure error for Delphi Low Pressure Sensors includes error due to linearity, hysteresis and ratiometricity. Delphi Low Pressure Sensors feature cutting-edge sensing technology and a patented Delphi Application Specific Integrated Circuit (ASIC) design. They are built in-house and provide high quality and reliable operation. Combined with Delphi's vast manufacturing experience, they offer quality and customer Delphi Low Pressure Sensors are cost-effective and they offer a patented, direct-mount design that can...

Open the catalog to page 3

All Delphi Power Train catalogs and technical brochures

  1. srs overview

    12 Pages

Archived catalogs

  1. Sensors

    12 Pages