video corpo

Sart Dec

Sart Dec
1 / 65 PagesView full catalog

Sart Dec

Product catalog summary
Product and Manufacturer
The manual covers the Negative Pressure Unit Smart Dec models S 50, S 200, and S 300 by deconta GmbH, providing instructions for safe and efficient use.
About the Instruction Manual
Designed for operators and safety specialists, the manual ensures safe and economical operation and should be retained until disposal.
Description of the Machine
Includes a general description, scope of delivery, operating modes, interfaces, nameplate information, and accessories for each model.
Technical Data
Details dimensions, weights, performance data, environmental conditions, noise emissions, and filter descriptions, including special versions of S 200 and S 300.
Security
Outlines intended use, potential misapplications, staff qualifications, and health and safety notes.
Transport
Details requirements for off-site and internal transport, including legislation and staff qualifications.
Assembly and Operation
Provides assembly and operation instructions, including manual and automatic operation, standby mode, and maintenance alerts.
Maintenance
Covers maintenance procedures, emphasizing personal protective equipment and including filter changes and troubleshooting.
Spare Parts and Circuit Diagrams
Lists spare parts and provides circuit diagrams for different voltage versions.
Storage and Disposal
Specifies environmental conditions for storage and outlines legal requirements for disposal.
EC Declaration of Conformity
Confirms compliance with European standards.
Overview of Operating Instructions
Emphasizes the importance of keeping instructions accessible and transferring them when the machine is handed over.
Warnings and Safety Instructions
Includes warnings categorized by severity and follows the SAFE method for hazard communication.
Symbols and Signs
Uses symbols to indicate warnings and required actions, such as wearing safety shoes.
Machine Description
Designed to filter asbestos-contaminated air using a 2-stage filter system, including a HEPA filter compliant with EN 1822 standards.
Security and Intended Use
Intended for filtering non-condensing asbestos-contaminated air, with specific instructions for use and limitations.
Misapplication and Unauthorized Use
Stresses the importance of compliance with safety and operational guidelines.
Staff Tasks and Qualifications
Outlines tasks and required qualifications for various personnel to ensure safe and effective use.
Occupational Health and Safety
Operators are responsible for implementing health and safety obligations and compliance with local regulations.
Transport
Must comply with local legislation, requiring qualified personnel and proper transport means.
Assembly
Machine should be integrated into the partition wall, ensuring proper sealing and air supply.
Operation
Operators must be trained, and the machine can be operated manually or automatically with remote monitoring capabilities.
Service and Maintenance
Maintenance settings are restricted to qualified service partners, and system settings include language selection.
Device Information and Alarms
Includes operational instructions and alarm systems, with visual and acoustic indicators for alarms.
Switching Off the Unit
Press the red 'OFF' button to turn off the unit, then remove the mains plug.
Maintenance
Maintenance is crucial, with tasks performed by authorized personnel. Filters should be monitored and replaced based on pressure readings.
Troubleshooting
Outlines common malfunctions and solutions, such as changing dirty filters.
Spare Parts and Circuit Diagrams
Original spare parts are recommended, and circuit diagrams are provided.
Storage and Disposal
Guidelines for safe storage and disposal, complying with local legislation.
EC Declaration of Conformity
Concludes with a declaration of compliance with EU directives and standards.
See more

Catalog excerpts

Sart Dec-1

C€ deconta GmbH Im Geer 20 46419 Isselburg E-mail: [email protected] Issue Date:

 Open the catalog to page 1
Sart Dec-2

Negative pressure unit smart dec S 50, S 200, S300 Original operating instructions

 Open the catalog to page 2
Sart Dec-3

Negative pressure unit smart dec S 50, S 200, S300 Original operating instructions

 Open the catalog to page 3
Sart Dec-4

Negative pressure unit smart dec S 50, S 200, S300 4 from 65 Original operating instructions Version 4

 Open the catalog to page 4
Sart Dec-5

group Product and manufacturer This operating manual describes the following product: Negative pressure unit smart dec. Negative pressure unit smart dec S 50, S 200, S300 Original operating instructions

 Open the catalog to page 5
Sart Dec-6

group About these instruction manual For proper and safe use of the machine, follow the descriptions and recommended actions in these operating instructions. Keep this manual for future reference until the machine has been disposed of. These operating instructions contain information on the safe, trouble-free and economical use of the machine. This information is intended for persons who perform tasks with or in connection with the machine. The following table gives an overview of persons and tasks. The operator shall make these operating instructions or extracts thereof available to persons...

 Open the catalog to page 6
Sart Dec-7

group About these instruction manual These operating instructions contain warnings of residual dangers. The classification of the warnings is based on the severity of the damage that can occur if the warnings are disregarded and recommended actions are not followed. 2.3.1 Signal words and signal colours Warnings are introduced with one of the following signal words and marked with a corresponding signal colour. Negative pressure unit smart dec S 50, S 200, S300 Original operating instructions

 Open the catalog to page 7
Sart Dec-8

group About these instruction manual The following symbols are used in these operating instructions. The warning sign is a safety sign that warns of a risk or danger. The following table gives an overview of warning signs used and their meaning. Negative pressure unit smart dec S 50, S 200, S300 Original operating instructions

 Open the catalog to page 8
Sart Dec-9

group Description of the machine This section contains information for understanding the machine. The machine (the Negative pressure unit) was designed and built by deconta GmbH, Im Geer 20, 46419 Isselburg. Negative pressure unit for filtering asbestos-contaminated room air via a 2-stage filter unit. The built-in HEPA filter complies with the requirements of EN 1822 class H 13 or H 14. Procedure for carrying out the risk assessment for machinery • Language of the risk assessment: German • Risk assessment: EN ISO 12100 Safety of machinery - General principles for design - Risk assessment and...

 Open the catalog to page 9
Sart Dec-10

group Description of the machine 3.4.1 Available operating modes The machine is intended exclusively for use in the following types of use. Use for other types of use is not in accordance with the intended use. User groups User environment ■ in rooms closed on all sides Operating modes ■ Automatic mode (SRE connect version only) This section contains information about interfaces. The following interfaces are available on the machine: ■ Human product: Control panel, touch screen ■ Product power supply: Electrical power supply 110 V / 230 V ■ Product offcuts: Connection spigot for clean air ■ Product...

 Open the catalog to page 10
Sart Dec-11

group Description of the machine The type plate contains information for identifying the machine. Aluminium plate, riveted Near the control panel on the discharge side. The following accessories are optionally available for the machine: Negative pressure unit smart dec S 50 Figure Discharge flange NW 150 Adhesive frame 3.7.2 Negative pressure unit smart dec S 200 Negative pressure unit smart dec S 50, S 200, S300 Original operating instructions

 Open the catalog to page 11
Sart Dec-12

group Description of the machine Negative pressure unit smart dec S 50, S 200, S300 Original operating instructions

 Open the catalog to page 12
Sart Dec-13

group Technical data Negative pressure unit smart dec S 50, S 200, S300 Original operating instructions

 Open the catalog to page 13
Sart Dec-14

group Technical data 4.3.2 Negative pressure unit smart dec S 200 Negative pressure unit smart dec S 50, S 200, S300 Original operating instructions

 Open the catalog to page 14
Sart Dec-15

group Technical data The S 200 and S 300 units of the smart dec series can be equipped with double filtration (2x HEPA filters in series) by means of an extended housing version. When using double filtration, the maximum volume flow and the unit dimensions change. The modified technical data can be found in the following tables. 4.4.1 Negative pressure unit smart dec S 200 Negative pressure unit smart dec S 50, S 200, S300 Original operating instructions

 Open the catalog to page 15
Sart Dec-16

group Technical data Noise emission Engine power 100%, outdoor area, values in dB (A) By attaching a silencer, the sound level can be reduced, taking into account power losses. Negative pressure unit smart dec S 50, S 200, S300 Original operating instructions

 Open the catalog to page 16
Sart Dec-17

group Technical data Integrated in the unit is a 2-stage filter combination Negative pressure unit smart dec S 50, S 200, S300 Original operating instructions

 Open the catalog to page 17
Sart Dec-18

group Technical data HEPA filter Negative pressure unit smart dec S 50, S 200, S300 Original operating instructions

 Open the catalog to page 18
Sart Dec-19

deconta group This section contains information on the protection of humans, domestic and farm animals and the environment. The machine is intended exclusively for the following use: The Negative pressure unit is used to filter non-condensing room air contaminated with asbestos fibres, in the temperature range up to +45 °C, with exhaust air discharge to the outside. During asbestos removal work inside closed rooms, it is important to exclude the possibility of asbestos fibres leaving the removal area and thus posing a danger to people and the environment. For these reasons, abatement areas (also...

 Open the catalog to page 19
Sart Dec-20

deconta group Use of the machine for the following purposes is not permitted: Reasonably foreseeable misuse ■ Any application other than that described in the operating instructions ■ Any use of the machine other than that described under "Intended use" without the written consent of the manufacturer. ■ Operation outside the technical limits of use ■ Unauthorised modifications or conversions as well as manipulation ■ Use, installation, operation, maintenance or repair in a manner other than described ■ Carrying out work by unqualified personnel ■ Use of unsuitable or incompatible materials, operating...

 Open the catalog to page 20

All Deconta GmbH catalogs and technical brochures

  1. FIRE BRIGADE

    2  Pages

  2. TRAILER C6000

    4  Pages

  3. TRAILER C5000

    4  Pages

  4. AIR PURIFIER

    2  Pages

  5. DEDUSTER

    2  Pages

  6. AIR SAMPLING

    2  Pages

  7. SMART DEC

    2  Pages

  8. GREEN DEC

    2  Pages

  9. S500SE

    34  Pages

  10. G600 & G700

    62  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.