Product and Manufacturer
The document provides operating instructions for the Negative Pressure Unit Smart Dec S 500 SE, manufactured by deconta GmbH. This unit is designed to filter asbestos-contaminated air using a 2-stage filter system, including a HEPA filter that meets EN 1822 class H 13 or H 14 standards.
Purpose of the Instructions
The instructions aim to ensure the safe, efficient, and economical use of the machine. They are intended for various professionals, including operators and maintenance technicians, and emphasize the importance of accessibility and transferability of the instructions.
Warnings and Symbols
Warnings are categorized by severity using terms like DANGER and WARNING, structured by the SAFE method. Symbols indicate warnings and instructions, such as electrical hazards and the need for protective clothing.
Machine Description
The unit is a negative pressure device for filtering asbestos fibers in enclosed spaces. It is not suitable for flammable gases or dusts. The machine operates manually and is intended for commercial use.
Technical Data
The unit measures 1080 x 750 x 1145 mm, weighs 117 kg without the filter, and has a maximum air flow of 13,300 m³/h. It operates on a 230 V power supply and includes a 2-stage pre-filter and a HEPA filter.
Security and Safety
Only specialized personnel should operate and maintain the machine. Safety instructions must be followed to prevent misuse. Unauthorized modifications and non-original parts are prohibited.
Transport and Assembly
Proper training and equipment are required for transport to avoid damage. The unit is delivered ready for operation and should be integrated into partition walls between clean and refurbishment areas.
Operation
The machine requires one trained operator and features manual stepless control for power regulation. It should not filter hot, flammable, or explosive materials.
Specifications and Procedures
Instructions for maintaining the unit include adjusting negative pressure levels and performing maintenance tasks with authorized personnel. Protective clothing is required during maintenance.
Maintenance and Warranty
Maintenance is essential for safety and functionality. Unauthorized modifications void the warranty. Filter changes must be performed by authorized personnel with the appliance disconnected from power.
Filter Maintenance
Filter changes are guided by specific Pascal values, and only approved filters should be used to prevent environmental hazards.
Troubleshooting
Potential faults and corrective measures are listed, such as changing dirty filters or inspecting the power source.
Storage and Waste Disposal
Storage guidelines include maintaining specific ambient conditions and thorough cleaning. Waste disposal must comply with legal regulations and be handled by qualified companies.
EC Declaration of Conformity
The document concludes with an EC Declaration of Conformity, confirming compliance with directives and standards, including the Machinery Directive and EMC Directive.
See more

Catalog excerpts

S500SE-1

deconta GmbH Im Geer 20 46419 Isselburg E-Mail: [email protected] Web: www.deconta.com

 Open the catalog to page 1
S500SE-2

Negative pressure unit smart dec S 500 SE Original operating instructions

 Open the catalog to page 2
S500SE-3

Negative pressure unit smart dec S 500 SE Original operating instructions

 Open the catalog to page 3
S500SE-4

group Product and manufacturer The following product is described in these operating instructions: Negative pressure unit smart dec S 500 SE. Negative pressure unit smart dec S 500 SE Original operating instructions

 Open the catalog to page 4
S500SE-5

group About these operating instructions To ensure proper and safe use of the machine, follow the descriptions and recommended actions in these operating instructions. Keep these operating instructions for future reference until the machine has been disposed of. These operating instructions contain information on the safe, trouble-free and economical use of the machine. This information is intended for persons who perform tasks with or in connection with the machine. The following table provides an overview of people and tasks. The operator shall make these operating instructions or extracts...

 Open the catalog to page 5
S500SE-6

group About these operating instructions These operating instructions contain warnings of residual dangers. The categorisation of the warnings is based on the severity of the damage that can occur if the warnings are ignored and the recommended actions are not followed. 2.3.1 Warning words and warning colours Warnings are introduced with one of the following warning words and marked with a corresponding warning colour. Negative pressure unit smart dec S 500 SE Original operating instructions

 Open the catalog to page 6
S500SE-7

group About these operating instructions The following symbols are used in these operating instructions. The warning sign is a safety sign that warns of a risk or danger. The following table provides an overview of the warning signs used and their meaning. Negative pressure unit smart dec S 500 SE Original operating instructions

 Open the catalog to page 7
S500SE-8

group Description of the machine This section contains information on understanding the machine. The machine (the Negative pressure unit) was designed and built by the company deconta GmbH, Im Geer 20, 46419 Isselburg. Negative pressure unit for filtering asbestos-contaminated room air via a 2-stage filter unit. The built-in HEPA filter fulfils the requirements of EN 1822 class H 13 or H 14. Procedure for carrying out the risk assessment for machinery • Language of the risk assessment: German • Risk assessment: EN ISO 12100 Safety of machinery - General principles for design - Risk assessment...

 Open the catalog to page 8
S500SE-9

group Description of the machine 3.4.1 Available operating modes The machine is intended exclusively for use in the following types of utilisation. Use for other types of utilisation is not in accordance with the intended purpose. User groups ■ in rooms closed on all sides Operating modes This section contains information about interfaces. The following interfaces are available on the machine: ■ Human - product: Control panel ■ Product - power supply: Electrical power supply 230 V ■ Product - waste products: Connection piece for clean air ■ Product - material feed: connection nozzle for contaminated...

 Open the catalog to page 9
S500SE-10

group Description of the machine The rating plate contains information for identifying the machine. 3.6.1 Execution Aluminium plate, riveted Near the control panel on the outlet side. Negative pressure unit smart dec S 500 SE Original operating instructions

 Open the catalog to page 10
S500SE-11

group Technical data Length x width x height Negative pressure unit SNAP double filtration Performance data All data on air performance and volume flow rates taking into account a measurement tolerance of ±15% in relation to the full-scale value, determined in a multi-point measurement procedure with a calibrated vane anemometer. Negative pressure unit smart dec S 500 SE Original operating instructions

 Open the catalog to page 11
S500SE-12

group Technical data All data on air performance and volume flow rates taking into account a measurement tolerance of ±15% in relation to the full-scale value, determined in a multi-point measurement procedure with a calibrated vane anemometer. The appliance can be equipped with double filtration (2x HEPA filters in series) using an optional "SNAP" add-on housing. When using double filtration, the maximum volume flow and the device dimensions change. The modified technical data can be found in the following tables. Negative pressure unit smart dec S 500 SE Original operating instructions

 Open the catalog to page 12
S500SE-13

Noise emission Status: Engine power 100%, outdoor area, values in dB (A) The sound level can be reduced by fitting a silencer, taking power losses into account. Negative pressure unit smart dec S 500 SE Original operating instructions

 Open the catalog to page 13
S500SE-14

group Technical data A 2-stage filter combination is integrated in the appliance Negative pressure unit smart dec S 500 SE Original operating instructions

 Open the catalog to page 14
S500SE-15

group Technical data HEPA filter Negative pressure unit smart dec S 500 SE Original operating instructions

 Open the catalog to page 15
S500SE-16

deconta group This section contains information on the protection of humans, pets, farm animals and the environment. The machine is intended exclusively for the following use: The Negative pressure unit is used for filtering non-condensing room air contaminated with asbestos fibres, in the temperature range up to +45 °C, with exhaust air discharge to the outside. When carrying out asbestos removal work in enclosed spaces, it is important to prevent asbestos fibres from leaving the removal area and thus posing a risk to people and the environment. For these reasons, removal areas (also known as...

 Open the catalog to page 16
S500SE-17

deconta group Use of the machine for the following purposes is not permitted: Reasonably foreseeable misuse ■ Any application other than that described in the operating instructions ■ Any use of the machine other than that described under "Intended use" without the written consent of the manufacturer ■ Operation outside the technical application limits ■ Unauthorised modifications or conversions and tampering ■ Use, installation, operation, maintenance or repair in a manner other than described ■ Work carried out by unqualified personnel ■ Use of unsuitable or incompatible materials, operating...

 Open the catalog to page 17

All Deconta GmbH catalogs and technical brochures

  1. FIRE BRIGADE

    2  Pages

  2. TRAILER C6000

    4  Pages

  3. TRAILER C5000

    4  Pages

  4. AIR PURIFIER

    2  Pages

  5. DEDUSTER

    2  Pages

  6. AIR SAMPLING

    2  Pages

  7. SMART DEC

    2  Pages

  8. GREEN DEC

    2  Pages

  9. G600 & G700

    62  Pages

  10. Sart Dec

    65  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.