Microboxer Specifications and types Zone 2 – Zone 22 Zone 1 – Zone 21 Zone 1 – Zone 21 Zona M2 IECEx II 3G Ex h IIB T4 Gc e II 3D Ex h IIIB T135°C Dc X II 2G Ex h IIB T4 Gb e II 2D Ex h IIIB T135°C Db X II 2G Ex h IIC T4 Gb ** I M2 Ex h I Mb X * Ex h IIB T4 Gb e Ex h IIIB T135°C Db ** The Group IIC gas application string is applicable on Boxer series pumps in Conduct version with Conductive TFM diaphragms. * The mining application string does not apply to aluminium pumps in the Boxer range. Suction / delivery connections Microboxer Suction / delivery connections FDA Boxer 30 Max negative suction head - dry-running** Max negative suction head - with pump primed Max. diameter suspended solids (*) NPT fittings only on request * The curves and the performances refer to pumps with immersed suction and open delivery outlet, with water at 20°C and vary depending on material composition. ** The value depends on the pump configuration. PLASTIC MATERIAL PP (GF/CF) - PVDF Construction mat. (casing and manifolds) and net weight POLYPROPYLENE (with glass additive) CONDUCTIVE POLYPROPYLENE (with carbon additive) PVDF (with carbon additive) AIR-OPERATED DOUBLE DIAPHRAGM PUMPS Height Width Depth DEBEM srl - Via Del Bosco, 41 - 21052 Busto Arsizio (VA) Italy - Tel. +39 0331 074034 - Fax +39 0331 074036 - [email protected] - www.debem.co
Open the catalog to page 1Microboxer Specifications and types Zone 2 – Zone 22 Zone 1 – Zone 21 Zone 1 – Zone 21 Zona M2 IECEx II 3G Ex h IIB T4 Gc e II 3D Ex h IIIB T135°C Dc X II 2G Ex h IIB T4 Gb e II 2D Ex h IIIB T135°C Db X II 2G Ex h IIC T4 Gb ** I M2 Ex h I Mb X * Ex h IIB T4 Gb e Ex h IIIB T135°C Db ** The Group IIC gas application string is applicable on Boxer series pumps in Conduct version with Conductive TFM diaphragms. * The mining application string does not apply to aluminium pumps in the Boxer range. Maximum dimensions Height Width Depth Construction mat. (casing and manifolds) and net weight 2 Kg Temp....
Open the catalog to page 2Zone 2 – Zone 22 Zone 1 – Zone 21 Zone 1 – Zone 21 Zona M2 IECEx 6 ** The Group IIC gas application string is applicable on Boxer series pumps in Conduct version with Conductive TFM diaphragms. 7 8 * The mining application string does not apply to aluminium pumps in the Boxer range. Flow rate (l/min) Air supply pressure (bar) II 3G Ex h IIB T4 Gc e II 3D Ex h IIIB T135°C Dc X II 2G Ex h IIB T4 Gb e II 2D Ex h IIIB T135°C Db X II 2G Ex h IIC T4 Gb ** I M2 Ex h I Mb X * Ex h IIB T4 Gb e Ex h IIIB T135°C Db MONOSTABLE distributor material (Distributor + spool) - (compressed air circuit) Core material...
Open the catalog to page 3Microboxer Zone 2 – Zone 22 Zone 1 – Zone 21 Zone 1 – Zone 21 Zona M2 IECEx II 3G Ex h IIB T4 Gc e II 3D Ex h IIIB T135°C Dc X II 2G Ex h IIB T4 Gb e II 2D Ex h IIIB T135°C Db X II 2G Ex h IIC T4 Gb ** I M2 Ex h I Mb X * Ex h IIB T4 Gb e Ex h IIIB T135°C Db ** The Group IIC gas application string is applicable on Boxer series pumps in Conduct version with Conductive TFM diaphragms. * The mining application string does not apply to aluminium pumps in the Boxer range. BOXER PUMPS CODES ENCODING ex. IMICR-P-HTTPV-Internal distributor, Microboxer, body PP, air-side diaph. Hytrel®, product-side diaph....
Open the catalog to page 4136 Pages
15 Pages
3 Pages
4 Pages
3 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
1 Page
2 Pages
2 Pages
5 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
2 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
28 Pages
11 Pages
14 Pages
40 Pages
33 Pages