Specifications and Types
The document provides detailed specifications for magnetic drive centrifugal pumps, specifically the DM and DM 06 models. Key specifications include suction fittings of 1” f BSPP or DN 25 - NPT, delivery fittings of 3/4” m BSPP or DN 20 - NPT, a maximum flow rate of 7 m3/h, and a minimum flow rate of 0.75 m3/h. The maximum head is 8.5 m, and the pumps can handle viscosities up to 150 cps.
Standard Electric Motor
The pumps are equipped with standard electric motors available in two configurations: 0.25 Kw (0.35 HP) and 0.37 Kw (0.5 HP), both with a constructive form of B3+B5, RPM of 2900, and three-phase 230/400 V, 50/60 HZ, 2 Poles IE2 Protection IP55. They operate in ambient temperatures ranging from -30°C to +45°C. Single-phase motors are also available.
Electric Motors Available on Request
Options include single-phase motors up to 3 kW, ATEX, and NEMA 56C (only the pump is available with an American flange for coupling with a NEMA motor, which is not included in the standard supply).
Impeller Specifications
The impeller sizes are Ø 81 mm, Ø 70 mm, and Ø 65 mm, with varying density capacities depending on the motor power.
Operating Temperatures and Weights
The pumps are made from PP (with glass additive) and PVDF (with carbon additive), with operating temperatures from 0°C to +70°C and -10°C to +100°C, respectively. The weights are 2.2 Kg for PP and 2.5 Kg for PVDF, excluding the motor.
Performance Curves
Performance curves are provided for different impeller sizes, showing flow rates and head measurements at 20°C with a two-pole motor at 50 Hz (2900 rpm).
Dimensions and Packaging
Dimensions are provided for different motor configurations, with length measurements in mm. The pumps are packaged in a wooden case measuring 50 x 25 x 35 cm, with a packaging weight of 7 Kg.
Sealing and Accessories
Sealing O-ring materials include EPDM and VITON®. Accessories available include a flange kit with DIN flanges, with ANSI flanges available on request.
See more

Catalog excerpts

DM 06-1

DM 06 Specifications and types Suction fittings Delivery fittings STANDARD ELECTRIC MOTOR: Kw 0,25 HP 0,35 • Constructive Form B3+B5 • RPM 2900 • Three-phase 230/400 V • 50/60 HZ • 2 Poles IE2 Protection IP55 • Ambient temperature -30°C + 45°C Kw 0,37 HP 0,5 PLASTIC MATERIAL • Constructive Form B3+B5 • RPM 2900 • Single-phase • Ambient temperature -30°C + 45°C Kw 0,37 HP 0,5 • Constructive Form B3+B5 • RPM 2900 • Single-phase • Ambient temperature -30°C + 45°C PLASTIC MATERIAL OPERATING TEMPERATURES** AND WEIGHTS PP (with glass additive) PVDF (with carbon additive) *The weights refer to the pump without the motor **Measurements should be taken with agitated water; temperatures may vary depending on the conditions of the system and/or the processed liquid ELECTRIC MOTORS AVAILABLE ON REQUEST: • Single-phase (up to 3 kw) • ATEX • NEMA 56C* *(only pump available, with American flange, for coupling with NEMA motor - the motor is not available in our standard) MAGNETIC DRIVE CENTRIFUGAL PUMPS DEBEM srl - Via Del Bosco, 41 - 21052 Busto Arsizio (VA) Italy - Tel. +39 0331 074034 - Fax +39 0331 074036 - [email protected] - www.debem.com • Constructive Form B3+B5 • RPM 2900 • Three-phase 230/400 V • 50/60 HZ • 2 Poles

 Open the catalog to page 1
DM 06-2

Flow rate (m3/h) The curves and performances refer to tested pumps, with water at 20 °C, two-pole motor 50 Hz (2900rpm). DEBEM srl - Via Del Bosco, 41 - 21052 Busto Arsizio (VA) Italy - Tel. +39 0331 074034 - Fax +39 0331 074036 - [email protected] - www.debem.com MAGNETIC DRIVE CENTRIFUGAL PUMPS

 Open the catalog to page 2
DM 06-3

DM 06 Specifications and types Length measurements in mm * Measurements may vary depending on the motor supplier. ** NPT or BSPP gas ***Warning: if you decide to combine the pump with a NEMA motor, the pump is delivered with a suitable coupling flange, but not the NEMA motor, which is not included in our standard supply. • EPDM • VITON® Packaging • Pump with 0,25/0,37 Kw motor • Wooden case size 50 x 25 x 35 cm - Weight 7 Kg DESCRIZIONE REVISIONI QUOTA SENZA INDICAZIONE DI TOLLERANZA SECONDO NORMA ISO 2768-m [email protected] DI PROPRIETA' RISERVATA PROTETTO A TERMINI DI LEGGE. E' ASSOLUTAMENTE...

 Open the catalog to page 3

All DEBEM SRL catalogs and technical brochures

  1. BOXER 7

    3  Pages

  2. BOXER 15

    4  Pages

  3. BOXER 35

    3  Pages

  4. BOXER 81 - 90

    4  Pages

  5. BOXER 100

    4  Pages

  6. BOXER 150

    4  Pages

  7. BOXER 502-522

    4  Pages

  8. BOXER 503

    4  Pages

  9. MICROBOXER

    4  Pages

  10. MIDGETBOX

    2  Pages

  11. CUBIC 15

    2  Pages

  12. TR

    5  Pages

  13. AISIBOXER-01

    2  Pages

  14. AISIBOXER-02

    2  Pages

  15. AISIBOXER-03

    2  Pages

  16. SANIBOXER-01

    2  Pages

  17. SANIBOXER-02

    2  Pages

  18. SANIBOXER-03

    2  Pages

  19. DM 10

    3  Pages

  20. DM 15

    3  Pages

  21. DM 30

    3  Pages

  22. KM 70

    3  Pages

  23. FULLFLOW 251

    2  Pages

  24. FULLFLOW 502

    2  Pages

  25. EQUAFLUX 51

    1  Page

  26. EQUAFLUX 100

    1  Page

  27. EQUAFLUX 200

    1  Page

  28. EQUAFLUX 302

    1  Page

  29. EQUAFLUX 303

    1  Page

  30. IM 80

    3  Pages

  31. IM 90

    3  Pages

  32. IM 95

    3  Pages

  33. IM 110

    3  Pages

  34. IM 120

    3  Pages

  35. IM 130

    3  Pages

  36. IM 140

    3  Pages

  37. IM 150

    3  Pages

  38. IM 155

    3  Pages

  39. IM 160

    3  Pages

  40. IM 180

    3  Pages

  41. IM 200

    3  Pages

  42. MB 80

    3  Pages

  43. MB 100

    3  Pages

  44. MB 110

    3  Pages

  45. MB 120

    3  Pages

  46. MB 130

    3  Pages

  47. MB 140

    3  Pages

  48. MB 150

    3  Pages

  49. MB 155

    3  Pages

  50. MB 160

    3  Pages

  51. MB 180

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.