1. Catalogs
  2. DATEXEL SRL
  3. DAT5028-DAT5024 SERIES: Trip amplifiers for DIN rail mounting

DAT5028-DAT5024 SERIES: Trip amplifiers for DIN rail mounting

DAT5028-DAT5024 SERIES: Trip amplifiers for DIN rail mounting

DAT5028-DAT5024 SERIES: Trip amplifiers for DIN rail mounting

Product catalog summary
Overview: The DAT5028 and DAT5024 series are trip amplifiers designed for DIN rail mounting, capable of accepting various sensor inputs. They are used in industries such as energy, food processing, machine industries, and water treatment.
DAT5028 Features:
  • Universal analog input for voltage, current, thermocouples (TC), resistance temperature detectors (RTD), and resistance.
  • Configurable trip alarms with a display for setting thresholds.
  • High accuracy with 1500 Vac galvanic isolation to prevent ground-loop effects.
  • Analog output options for signal transmission.
  • EMC compliance and CE marking.
DAT5024 Features:
  • Dedicated analog input for RTD, TC, voltage, resistance, and current.
  • Two independent thresholds for high or low alarms, adjustable via potentiometers.
  • 2000 Vac isolation between input, power supply, and relay contacts.
  • High accuracy and EMC compliance.
DAT5024E Features:
  • Economic model with input for voltage and current.
  • Configurable alarms via dip-switches with adjustable trip levels, hysteresis, and delay.
  • 1500 Vac isolation for power supply and input, 1000 Vac for relay contacts.
  • Suitable for DIN rail mounting with EMC compliance.
Technical Specifications:
  • Temperature range: Operative -30°C to +60°C, Storage -40°C to +85°C.
  • Humidity: 0 to 90% non-condensed.
  • Power supply: 12 to 30 Vdc for DAT5028, 18 to 32 Vdc for DAT5024, and 18 to 30 Vdc for DAT5024E.
  • Relay outputs: SPDT and SPST configurations with specific load ratings.
Applications: These devices are suitable for environments requiring precise control and monitoring, such as energy management, food processing, industrial machinery, and water treatment systems.
See more

Catalog excerpts

DAT5028-DAT5024 SERIES: Trip amplifiers for DIN rail mounting-1

ELECTRONIC AND CONTROL PROCESS DEVICES DAT5028-DAT5024 SERIES: Trip amplifiers for DIN rail mounting The devices of the “DAT5028 - DAT5024” series can accept on input several types of sensor coming from the field. • TRIP AMPLIFIERS with universal analog input configurable by Dip-switch indication on display of the trip level value (DAT5028) • TRIP AMPLIFIERS with dedicated analog input (DAT5024) • TRIP AMPLIFIERS with configurable input Voltage or Current (DAT5024E) Trip amplifier with display for universal analog input 41 • DAT 5024 Trip amplifier with dedicated analog input Economic, isolated trip amplifier configurable by

 Open the catalog to page 1
DAT5028-DAT5024 SERIES: Trip amplifiers for DIN rail mounting-2

Trip “DAT5028 / DAT5024 series” trip amplifiers amplifiers for DIN rail mounting TRIP AMPLIFIERS

 Open the catalog to page 2
DAT5028-DAT5024 SERIES: Trip amplifiers for DIN rail mounting-3

TRIP AMPLIFIER WITH DISPLAY FOR UNIVERSAL ANALOG INPUT GENERAL DESCRIPTION The DAT 5028 device is able to acquire RTD or Tc sensors, mV, V or mA input signals connected to the universal analog input. By means of push-button and 4-digit display on the front panel, four different trip alarms are configurable. Each alarm threshold commands an output relay. Input signal can be retransmitted on the analog output in a Voltage or Current signal, configurable by means of dip-switch on the side of the device. By means of an internal 16 bit converter, the device guarantees high accuracy and a stable measure...

 Open the catalog to page 3
DAT5028-DAT5024 SERIES: Trip amplifiers for DIN rail mounting-4

CDDAlEXEL GENERAL DESCRIPTION The trip amplifier DAT 5024 is able to accept on its input a wide range of normalised voltage signals, normalised current signals coming from both active and passive current loop, signals coming from RTDs, Thermocouples and resistance sensors. The input type and the input range are fixed: refer to the section "Technical Specifications”, table " Input type ” to order the device. The Threshold 1 is programmed as high alarm, while, by dip-switches, it is possible to set the Threshold 2 either as high or low alarm. The trip level of each threshold can be adjusted by...

 Open the catalog to page 4
DAT5028-DAT5024 SERIES: Trip amplifiers for DIN rail mounting-5

ECONOMIC, ISOLATED TRIP AMPLIFIER CONFIGURABLE BY DIP-SWITCHES GENERAL DESCRIPTION The DAT 5024E is an economic trip amplifier able to accept on its input normalised voltage and current signals coming from both active and passive current loops. Both the trips can be configured as high or low alarm, the adjustment of the trip values is performed by the potentiometers THR1 and THR2 located on the front side of the device. The adjustment of the hysteresis and delay value can be performed by the potentiometers accessible opening the suitable door located on the side of the device. On the devices...

 Open the catalog to page 5
DAT5028-DAT5024 SERIES: Trip amplifiers for DIN rail mounting-6

TRIP AMPLIFIERS ELECTRONIC AND CONTROL PROCESS DEVICES “DAT5028 / DAT5024 series” trip amplifiers for din rail mounting Application areas

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.