DAT3000-1

• DAT 3580 Isolated converter RS232^-MRS485 / 422 DAT 3580-USB Isolated converter USB^-^-RS485 / 422 • DAT 3580-MBTCP Isolated Ethernet Gateway Modbus TCP^-^-Modbus RTU DAT 3590 Repeater/ Isolator RS485 / 422 • DAT 3130 Distributed I/O Module 4 digital inputs + 4 relay outputs on RS-485 network DAT 3140 Distributed I/O Module 4 digital inputs + 8 NPN outputs on RS-485 network • DAT 3148/8 Distributed I/O Module 8 digital inputs on RS-485 network DAT 3148/12 Distributed I/O Module 12 digital inputs on RS-485 network • DAT 3188/4 Distributed I/O Module 4 digital inputs + 8 PNP outputs on RS-485 network lEXEL "DAT3000 SERIES" data acquisition and control modules The distributed I/O modules of the DAT3000 series represent a complete solution for the acquisition and control of the analog and digital I/O signals. The series is composed of: • Serial line converters and repeaters (DAT3580, DAT3580 USB, DAT3580 MBTCP, DAT3590). • Modules for digital inputs and outputs (DAT3130, DAT3140, DAT3148/8, DAT3148/12, DAT3188/4, DAT3188/8). • Modules for analog inputs (DAT3011, DAT3014, DAT3015, DAT3016, DAT3017, DAT3018, DAT3019). • Modules with analog outputs (DAT3022, DAT3024, DAT3028). The devices communicate on the RS-485 serial line by the MODBUS RTU communication protocol and are able to communicate with the host computer on multipoint net using only two wires. DAT 3188/8 Distributed I/O Module 8 digital inputs + 8 PNP outputs on RS-485 • DAT 3011 Universal Remote I/O module on RS-485 network • DAT 3014 Remote I/O module 4 channels RTD input on RS-485 network DAT 3015-I Remote I/O module 4 channels +/-20mA input on RS-485 network • DAT 3015-V Remote I/O module 4 channels +/-10V input on RS-485 network DAT 3016 Remote I/O module 4 channels mV / TC input on RS-485 network • DAT 3017-I Remote I/O module 8 channels ±20mA input on RS-485 network DAT 3017-V Remote I/O module 8 channels ±10V input on RS-485 network • DAT 3018 Remote I/O module 8 channels mV / TC input on RS-485 network DAT 3019 Remote I/O module 8 channels RTD input on RS-485 network • DAT 3022 Remote I/O module 2 channels V / mA output on RS-485 network DAT 3024 Remote I/O module 4 channels V / mA output on RS-485 network • DAT 3028 Remote I/O module 8 channels Voltage output on RS-485

 Open the catalog to page 1
DAT3000-2

DAT3000 Data acquisition and SERIES control modules

 Open the catalog to page 2
DAT3000-3

ISOLATED CONVERTER RS232^-»>RS485 / 422 GENERAL DESCRIPTION The device DAT3580 is an isolated interface converter between asynchronous serials lines RS232 and RS485 or RS422 that guarantees a full isolation between power supply, serial line RS-232 and serial line RS-485 or 422 removes eventual ground-loop effects, allowing the use of the device even in the heavy environmental conditions. It is designed to operate either on serial interface RS-422 full-duplex 4 wires or RS485 half-duplex 2 wires, with a baud-rate transmission up to 115.2 Kbps. The transmission is asynchronous without settings...

 Open the catalog to page 3
DAT3000-4

ETHERNET ISOLATED GATEWAY MODBUS TC^-^MODBUS RTU GENERAL DESCRIPTION The gateway DAT3580-MBTCP allows to connect the Modbus RTU devices of a RS-485 network to the Ethernet network through the Modbus TCP protocol. By means of the Telnet interface it is possible to configure all the Modbus TCP side options (IP address, subnet mask, etc..) and the Modbus RTU side options (baud rate, etc...). The device guarantees a full isolation between lines, allowing the use even in the heavy environmental conditions. FEATURES - Network interface - Distance up to 1200 m, up to 32 devices in multipoint - Ethernet...

 Open the catalog to page 4
DAT3000-5

DISTRIBUTED I/O MODULE 4 DIGITAL INPUTS + 4 RELAY OUTPUTS ON RS-485 NETWORK GENERAL DESCRIPTION The device DAT 3130 is able to acquire up to 4 digital inputs and to drive up to 4 relay outputs. The data are transmitted with MODBUS RTU/ASCII protocol on RS-485 network. To assure safe operation of the system, the device is equipped with two Watch-Dog timers: in case of alarm, the outputs are forced automatically on the safe configuration. The 1500 Vac galvanic isolation between inputs, outputs, power supply and RS-485 serial line cancels any ground-loop effect noise, allowing the use of the device...

 Open the catalog to page 5
DAT3000-6

CDDAlEXEL GENERAL DESCRIPTION The device DAT 3148/8 is able to acquire up to 8 digital inputs. The data are transmitted with MODBUS RTU/ASCII on RS-485 network. To assure safe operation of the system, the device is equipped with two Watch-Dog timers. The 2000 Vac galvanic isolation between inputs, power supply and RS-485 serial line cancels any ground-loop effect noise, allowing the use of the device in worst ambient conditions. FEATURES - Field Bus data acquisition - Master/Slave communication on RS-485 network - MODBUS RTU/ASCII protocol - 8 digital inputs - Watch-Dog alarm POWER SUPPLY EMC...

 Open the catalog to page 6
DAT3000-7

DISTRIBUTED I/O MODULE 4 DIGITAL INPUTS + 8 PNP OUTPUTS ON RS-485 NETWORK GENERAL DESCRIPTION The device DAT 3188/4 is able to acquire up to 4 digital inputs and to drive up to 8 transistor outputs. The data are transmitted with MODBUS RTU/ASCII protocol on RS-485 network (is available the RS-232 interface model). To assure safe operation of the system, the device is equipped with two Watch-Dog timers: in case of alarm, the outputs are forced automatically on the safe configuration. Also, the outputs are protected against over currents and over temperature. The 2000 Vac galvanic isolation between...

 Open the catalog to page 7
DAT3000-8

UNIVERSAL REMOTE I/O MODULE ON RS-485 NETWORK GENERAL DESCRIPTION The device DAT 3011 is able to acquire RTD or Tc sensors, mV, V or mA input signals connected to the universal analog input. Moreover a second V/mA analog input is available. The device is able to acquire up to 3 digital inputs and to drive one solid-state relay and two SPST relays. Data values are transmitted with MODBUS RTU protocol on the RS-485 network. By means of a 16 bit converter, the device guarantee a high accuracy and a stable measure versus time and temperature. To ensure the plant safety, two Watch-Dog timer alarms...