DT1102 Leaflet of product

DT1102 Leaflet of product
1 / 2 +++fo_common_label_pages+++ Pages+++foj_catalog_detail_view+++ View full catalog

DT1102 Leaflet of product

+++foj_catalog_detail_summary+++ Product catalog summary
Overview: The DT1102 (PS) Switch Selectable Input-Output Galvanic Isolator is designed for signal transmission and conversion between DC current or voltage sources and signal processing units. It features complete 3-way isolation between input, output, and power supply, with a continuous isolation voltage of 250 VACeff.
Specifications:
  • Input/Output Ranges: Selectable via front panel switches for 0-20 mA, 4-20 mA, 0-10 V, and 2-10 V.
  • Isolation: 3-way isolation with a working voltage of 250 Veff and 2500 VDC for 1 minute.
  • Power Supply: Available in two versions - 24 V ± 10% DC (DT1102) and 230 V ± 10% AC/DC (DT1102 PS).
  • Non-linearity: Less than 0.01%.
  • Temperature Coefficient: Typically 25 ppm/°C.
  • Power Consumption: 1.6 W for DT1102 and 2.4 W / 3.8 VA for DT1102 PS.
Features:
  • Provides 20 VDC / 24 mA on the input for passive two-wire transmitters.
  • Front panel LEDs indicate power and error states.
  • TS-35 rail mounting with a width of 12.5 mm.
Safety and Compliance:
  • Complies with EN 61010-1 for isolation and EN 61326-1 for electromagnetic compatibility.
  • Pollution Level: 2, Measurement Category: II.
  • Protection: IP 20.
Environmental Conditions:
  • Operating Temperature: 0-50 °C, extendable to -20 to +50 °C upon request.
  • Relative Humidity: Maximum 90% non-condensing.
Physical Characteristics:
  • Dimensions: 12.5 × 108 × 114 mm (width × height × depth).
  • Weight: 0.15 kg.
  • Housing Material: Polyamide PA6.6.
Contact Information: DATCON, H-1148 Budapest, Fogarasi út 5., Hungary. Tel: +361 460-1000, Email: [email protected], Website: www.datcon.eu
+++foj_catalog_detail_summary_more+++ See more

+++fo_catalog_detail_extractsFromCatalogTitle+++ Catalog excerpts

DT1102 Leaflet of product-1

Type designation Product features Switch Selectable Input-Output Galvanic Isolator • Selectable input/output ranges with front panel switches: 0-20 mA / 4-20 mA / 0-10 V / 2-10 V input 0-20 mA / 4-20 mA / 0-10 V / 2-10 V output • 3 way isolation • 20 VDC transmitter supply on the input for two wire transmitters • Non-linearity: < 0.01% • Temperature-coefficient: 25 ppm / °C typ. • 24 V ± 10% DC, 230 V ± 10% AC/DC power supply • TS-35 rail mounting, 12.5 mm width 24 VDC POWER SUPPLY 230 V AC/DC POWER SUPPLY The DT1102 (PS) Switch Selectable Input-Output Galvanic Isolator provides signal transmission and conversion between DC current or DC voltage signal source and signal processing units. The instruments feature complete 3-way isolation: the input, the output and the power supply are isolated from each other. Continuous isolation voltage is 250 VACeff, between the input, the output and the power supply. The instrument provides 20 VDC / 24 mA on the input for supplying passive two wire transmitters. The DT1102 is particularly advantageous in industrial plants where different signal levels are in use. The input/output ranges are selectable with front panel switches: • 0-20 mA / 4-20 mA / 0-10 V / 2-10 V input • 0-20 mA / 4-20 mA / 0-10 V / 2-10 V output The instruments has two inputs: • current: 0 (4) mA - 20 mA* • voltage: 0 (2 ) V - 10 V* The instruments has two outputs: • current: 0 (4) mA - 20 mA* • voltage: 0 (2) V - 10 V* * it may be use only one input and one output at a time. There are two power supply version: DT1102: 24 V ± 10% DC, DT1102 PS: 230 V ± 10% AC/DC. The transmission parameters are outstandingly good: the non-linearity is < 0.01%, and the temperature coefficient is < 25 ppm / °C TYP. Front panel LED’s indicate the power on state and the error states (input / output overrange, internal errors, ...). H-1148 Budapest, Fogarasi út 5., Hungary Tel.: +361 460-1000 Fax: +361 460-1001 e-mail: [email protected] www.datcon.eu

 +++foj_catalog_detail_pageCatalogLinkLabel+++ Open the catalog to page 1
DT1102 Leaflet of product-2

Technical specification Safety data: The connection terminals of the supply voltages are isolated from each other, the isolation is in compliance with the standard EN 61010-1, taking into consideration the following: Pollution level: Measurement category: Input parameters: Input signal: 400 mA (current input) 100 V (voltage input) Input resistance (current input): Input resistance (voltage input): Transmitter power supply: Voltage: Overcurrent protection: Output parameters: Output signal: 0-20 mA, 4-20 mA (current output) 0-10 V, 2-10 V (voltage output) Overdriving ability: 22.5 mA (current output)...

 +++foj_catalog_detail_pageCatalogLinkLabel+++ Open the catalog to page 2

+++foj_catalog_stand_metaTitle+++ All Datcon Industrial Electronics Ltd. catalogs and technical brochures

  1. Leaflet of DT1104 UI RS4

    2  +++fo_common_label_pages+++ Pages

  2. Leaflet of DT1122

    2  +++fo_common_label_pages+++ Pages

  3. Leaflet of DT1102 V

    2  +++fo_common_label_pages+++ Pages

  4. Leaflet of DT1102 ROOT

    2  +++fo_common_label_pages+++ Pages

  5. Leaflet of DT1102 INV

    2  +++fo_common_label_pages+++ Pages

  6. Leaflet of DT1102 IP

    2  +++fo_common_label_pages+++ Pages

  7. DT1400

    72  +++fo_common_label_pages+++ Pages

  8. DT1300

    2  +++fo_common_label_pages+++ Pages

  9. DT700 DP / DT701 DP

    2  +++fo_common_label_pages+++ Pages

  10. DT720 ... Pressure transmitters

    2  +++fo_common_label_pages+++ Pages

  11. DT4200, DT420 E Process Indicators

    2  +++fo_common_label_pages+++ Pages

+++fo_stand_catalog_archivedcatalog+++ Archived catalogs

  1. DEMS5005

    2  +++fo_common_label_pages+++ Pages

  2. DT320 ... / DT321 ... Over-voltage protectors

    2  +++fo_common_label_pages+++ Pages

  3. DT700 Pressure meter / transmitters

    2  +++fo_common_label_pages+++ Pages

+++fo_prices_excludedTaxes_globalMessage+++ *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.