DEMS5005

DEMS5005

DEMS5005

Product catalog summary
Overview: The DEMS5005 Pulse Collector is designed to integrate pulse-output transmitters, such as volume and consumption meters, into process control systems. It simplifies the connection of various devices through its dual functions: counting incoming pulses and measuring the time between them.
Functions:
  • Counting of incoming pulses for consumption and metering.
  • Measuring time between pulses for momentary consumption and flow-volume measurement.
Connectivity: The device connects to signal-processing computers or PLCs via RS232/RS485 interfaces using the MODBUS RTU protocol. It supports NAMUR and contact inputs, with line-fault detection for NAMUR inputs.
Measurement Ranges: Two ranges are available: 0-10 Hz (bounce-free) and 0-50 Hz. Input modes include activation by rising/falling edges or contact closure/opening.
Configuration: Operating parameters can be set and monitored via a PC using a USB connection. Parameters include input selection, mode, and frequency range.
Power Supply: Available in two versions: 18-40 V AC/DC and 180-250 V AC.
Technical Specifications:
  • 8 NAMUR/contact inputs.
  • RS232/RS485 communication with MODBUS RTU protocol.
  • Configurable via USB port.
  • Power supply options: 24 V AC/DC, 230 V AC/DC.
  • TS-35 rail mounting, 45 mm width.
Safety and Compliance: The device complies with EN 61010-1 for isolation, EN 60947-5-6 for NAMUR inputs, and EN 61326 for EMC. It is designed for industrial environments with a pollution level of 2 and measurement category II.
Environmental Conditions: Operating temperature range is 0-50 °C (extendable to -20-50 °C upon request), with a maximum relative humidity of 90% (non-condensing). Installation is recommended in a cabinet.
Physical Characteristics: The device is housed in a polyamide PA6.6 terminal assembly box, suitable for TS-35 rail mounting. It measures 45 × 99 × 115 mm and weighs 0.2 kg, with IP 20 protection.
Additional Information: Detailed operating instructions are available, and the manufacturer reserves the right to modify technical data.
See more

Catalog excerpts

DEMS5005-1

Product features Pulse Collector • 8 × NAMUR / contact inputs • Counting of incoming pulses • Measuring the time between the incoming pulses • RS232 / RS485 communication, MODBUS RTU protocol • Configurable from PC via USB port • 24 V AC/DC, 230 V AC/DC power supply • TS-35 rail mounting, 45 mm width The DEMS5005 Pulse Collector has the function to integrate into the system those pulse-output transmitters (volume meters, consumption meters, etc.), which are connected to the inputs of the device. Through the use of this device, it becomes simple to connect various devices to process control systems. This device performs two different functions: •  Counting of incoming pulses (consumption / metering), and •  Measuring the time between the incoming pulses (momentary consumption metering, flow-volume measurement, etc.). The DEMS5005 can be connected to a signal-processing computer, or to a PLC through a communication interface RS232 / RS485, the communication protocol is: MODBUS RTU. NAMUR and contact outputs can be connected to the input of the pulse collector. In the event of NAMUR input transmitters, the device is equipped with a line-fault detection function to monitor of short or open circuit lines. Two different measurement ranges are available for selection: 0-10 Hz (here the input is bounce-free), and 0-50 Hz. The user can select from the following input modes: the device is activated by rising or falling edges, or (in the case of a contact), the device is activated by the closing or the opening of the contact. The operating parameters can be specified and downloaded by a simple configurating programme, running on a PC. Such parameters are: input selection (NAMUR / contact), input mode (rising signal / falling edge detection), frequency range. In on-line mode, the program allows for a continuous monitoring of all inputs. The pulse collector device can be connected to a configurating computer via an USB port. The DEMS5005 has to power supply versions: 18-40 V AC/DC (DEMS5005) or 180-250 VAC (DEMS5005 PS). The device preserves the settings and the measured pulse numbers for an unlimited period of time. H-1148 Budapest, Fogarasi út 5., Hungary Tel.: +361 460-1000 Fax: +361 460-1001 e-mail: [email protected] www.datcon.eu

 Open the catalog to page 1
DEMS5005-2

Technical specification Safety data: The connection terminals of the input/output supply voltages are isolated from each other, the isolation is in compliance with the standard EN 61010-1, taking into consideration the following: Pollution level: Measurement category: Input parameters: Number of channels: Measured quantities: counting of incoming pulses (consumption metering) measuring the time between the incoming pulses (momentary consumption metering, flow-volume measurement, etc.) NAMUR input: No load voltage: 8.2 V (in compliance with the standard EN 60947-5-6 (NAMUR)) Short circuit current:...