STANDARD VAC FLUSH M12 conn Nominal Voltage Residual Ripple Hysteresis Max. Output Current Min. Output Current Residual Current Voltage Drop Operation Led Switching Frequency Start Up Delay Repeatability Short Circuit Protection 20+250 Vac (50,60 Hz) < 10% < 10% 500 mA, inrush:1,5A 20 mA < 0,7 mA < 4 V (I=100mA) Yellow 25 Hz < 300 ms 5% Present (self-resetting) 20+250 Vac (50,60 Hz) < 10% < 10% 500 mA, inrush:1,5A 20 mA < 0,7 mA < 4 V (I=100mA) Yellow 25 Hz < 300 ms 5% Present (self-resetting) Electric Protection Against polarity reversal inductive loads Against polarity reversal inductive loads (-25 ... +70 °C) IP67 ----Nickel-plated brass PA 16 * see page 5 of the Inductive Sensors Catalog --95g (-25 ... +70 °C) IP67 2m 2 x 0,25 mm² Nickel-plated brass PA 16 * see page 5 of the Inductive Sensors Catalog 145g --- NOMINAL SWITCHING DISTANCE 10-30 Vdc PNP/NPN NO-NC NAMUR amplifier order No. order No. order No. order No. order No. order No. order No. order No. order No. order No. order No. order No. order No. Temperature Limit Protection Degree Cable Length Cable Section Housing Material Active face Tightening torque Weight - Cable Output Weight - Connector Output CATALOG | Inductive and Capacitive Sensors
Open the catalog to page 1STANDARD VAC FLUSH M12 conn Nominal Voltage Residual Ripple Hysteresis Max. Output Current Min. Output Current Residual Current Voltage Drop Operation Led Switching Frequency Start Up Delay Repeatability Short Circuit Protection 20+250 Vac (50,60 Hz) < 10% < 10% 500 mA, inrush:1,5A 20 mA < 0,7 mA < 4 V (I=100mA) Yellow 25 Hz < 300 ms 5% Present (self-resetting) 20+250 Vac (50,60 Hz) < 10% < 10% 500 mA, inrush:1,5A 20 mA < 0,7 mA < 4 V (I=100mA) Yellow 25 Hz < 300 ms 5% Present (self-resetting) Electric Protection Against polarity reversal inductive loads Against polarity reversal inductive loads...
Open the catalog to page 2STANDARD VAC FLUSH M12 conn Nominal Voltage Residual Ripple Hysteresis Max. Output Current Min. Output Current Residual Current Voltage Drop Operation Led Switching Frequency Start Up Delay Repeatability Short Circuit Protection 20+250 Vac (50,60 Hz) < 10% < 10% 500 mA, inrush:1,5A 20 mA < 0,7 mA < 4 V (I=100mA) Yellow 25 Hz < 300 ms 5% Present (self-resetting) 20+250 Vac (50,60 Hz) < 10% < 10% 500 mA, inrush:1,5A 20 mA < 0,7 mA < 4 V (I=100mA) Yellow 25 Hz < 300 ms 5% Present (self-resetting) Electric Protection Against polarity reversal inductive loads Against polarity reversal inductive loads...
Open the catalog to page 3Inductive AC 1) SC protection see tech. data Double key connector for inductive AC sensors CATALOG | Inductive and Capacitive Sensors
Open the catalog to page 4Stainless Steel housing LCP active face Short length Operating distance 0.8 … 15 mm M5, M8, M12, M30 Cable, M8 or M12 connector 2 wires IP67 protection REDUCTION FACTOR ALUMINUM (25°C) M12/18/30 FLUSH models are ATEX certified I I 3G EX nA II T6 I I 3D EX t
Open the catalog to page 54 Pages
5 Pages
7 Pages
9 Pages
5 Pages
6 Pages
3 Pages
4 Pages
9 Pages
9 Pages
8 Pages
4 Pages
4 Pages
5 Pages
6 Pages
7 Pages
6 Pages
4 Pages
4 Pages
4 Pages
4 Pages
1 Page
7 Pages