Medium resolution area sensors IP67 protection degree (IP69K special model) Complete protection against electrical damages Detection of objects with irregular shape ATEX models, cat. 2 and cat. 3, available on request Crossed beams detection Medium resolution Application notes Catalogue / Manuals code description series optics emitter / receiver Compact area sensor 10 optics, 90 mm area height, 10 mm optic step cable exit distance Emitter with sensitivity adjustment Kit emitter + receiver Emitter Emitter with check 4 optics, 90 mm area height, 30 mm optic step Receiver NO (Dark ON) Receiver NC (Light ON) Emitter Receiver NPN + PNP M12 plug cable exit Cable exit Sensing distance 0.3 ... 2 m (standard version) Standard version Models with 4 m sensing distance Models with 6 m sensing distance Models with aluminium enclosure and air cooling inlet Models with glass optic window Models with impulse synchronisation Models with reduced sensing distance 100...350 mm Models with IP69K protection ATEX models 3 GD
Open the catalog to page 1available models Medium resolution receiver 0.3...2 emitter 90 emitt. + check Ø 15 (1) Ø 7.5 (2) Ø 5 (3) Guaranteed resolution everywhere in the detection area Guaranteed resolution in the central part of the detection area with exclusion of the dark zones (3) As note (2), but with sensivity adjustment (4) NC output models available on request Dark zones are parts of the detection area close to the emitter and receiver, their amplitude X is proportional to the distance D between the emitter and the receiver. BX04 => X = 0,17D BX10 => X = 0,06D (1) (2)
Open the catalog to page 2technical specification 0.3...2 m (standard model) 0.3...1,5 m (model DA) 0.3...4 m (model 6X) 0.3...6 m (model 6A) nominal sensing distance controlled height n° of beams beams space minimum detectable object Medium resolution supply voltage no-load supply current load current leakage current voltage drop output type response time (light/dark) response time (dark/light) power supply protections polarity reversal, transient short circuit (autoreset) sensitivity adjustment operative temperature range temperature drift interference to external light 1000 lux (incandescent lamp) 1500 lux (sunlight)...
Open the catalog to page 3electrical diagrams of the connections BX04 - BX10 receiver Medium resolution
Open the catalog to page 4Medium resolution
Open the catalog to page 54 Pages
5 Pages
7 Pages
9 Pages
5 Pages
6 Pages
5 Pages
3 Pages
4 Pages
9 Pages
9 Pages
8 Pages
4 Pages
4 Pages
5 Pages
6 Pages
7 Pages
4 Pages
4 Pages
4 Pages
4 Pages
1 Page
7 Pages