Data Sheet DP-40044-00-000 xtremeDBm xDBm06-CAN Molded Plastic Module 4 Pin Splitter Housing Dimensions (l x w x h) Weight Installation (mounting hardware not included) Mating Connectors and Accessories Technical Data Molded glass filled nylon 2.000 x 9.375 x 1.34 in (51 x 239 x 34 mm) 0.66 lbs (0.30 kg) Screw: 2 x #10 (2 x M5) Torque: 21 in-lbs (2.4 Nm) max. 4 Pole Plug 10 x DT06-4S or equivalent DEUTSCH® size 16 Socket 0462-201-16141 0462-16-0122 114017 6 8…32 V DC 13 A per circuit max. 26 A max. -40…85 °C -40…85 °C IP67: Connector seal plugs required for unused pins. Sealing plugs required for unused ports IP68/IP69K: Using MDC xtreme cables. DEUTSCH® Seal Plug Total CAN Splitters Operating Voltage (Power) Switching Current Total Current (Power) Operating Temperature Storage Temperature Protection Class Data Sheet xtremeDBm CAN Splitter xDBm06-CAN Sheet The trademark DEUTSCH is owned by the TE Connectivity Ltd. family of companies
Open the catalog to page 1Operating States (LEDs) PWR Color Blue Status Module and Ports power are connected Test Standards and Regulation Cold Temperature to IEC 60068-2-1:2007, test Ad Dry Heat to IEC 60068-2-2:2007, test Bb Temperature Durability to IEC 60068-2-14:2000-08, test Nb Temperature Shock to IEC 60068-2-14:2000-08, test Na Humidity Soak to IEC 60068-2-78:2001, test Cab Humidity Cycle to IEC 60068-2-30:2005, test Db Swept Sine Vibration to IEC 60068-2-6:2007, test Fc Random Vibration to IEC 60068-2-64:2008, test Fh Mechanical Shock to EN 60068-2-27:2008, test Ea Mechanical Bump to EN 60068-2-27:2008,...
Open the catalog to page 2Connector Interface Connections: Ports J1 to J6 Pin 1 = POWER Pin 2 = CAN HIGH Pin 3 = GROUND Pin 4 = CAN LOW Ports are connected internally in series with each other to conform to trunk/drop system. Power LED Pin 1 to Pin 3 Article Numbers 4 Pin Deutsch Splitter w/ LED (Pin 1 to Pin 3) Data Sheet xtremeDBm CAN Splitter xDBm06-CAN Sheet The trademark DEUTSCH is owned by the TE Connectivity Ltd. family of companies.
Open the catalog to page 3Application Notes BUS LINE / BACKBONE DROP LINE / CABLE TAIL Sample Topology of Drop Lines: The following table shows the maximum drop line lengths and the maximum length of the CAN bus line. The table specifies the maximum drop line lengths and the maximum length of the CAN bus line (drop lines not included) using a splitter. Baud Rate 1 Mbit/s 500 kbit/s 250 Kbit/s 125 Kbit/s Drop Line Length < 0.3 m < 1.2 m < 2.4 m < 4.8 m SIGNAL REFLECTIONS CAUSED BY DROP LINES! Drop lines can give rise to signal reflections in CAN networks. When using splitters in CAN networks, the possible drop line...
Open the catalog to page 4All Data Panel GmbH catalogs and technical brochures
-
DP-ESTOP-569XXXX
6 Pages
-
DP-38022-2
2 Pages
-
DP-34044-3-000
5 Pages