DS400UB-10V

DS400UB-10V

DS400UB-10V

Product catalog summary
Features: The DS400UB-10V current transducer features a maximum linearity error of 27 ppm, a 10V BNC output connection, and utilizes fluxgate, closed-loop compensated technology for high accuracy and stability. It includes a DSUB 9 pin connection, a green diode for operation indication, and an aluminum body for EMI shielding and temperature range extension. It supports non-intrusive, isolated DC and AC current measurement up to 440A.
Applications: This device is suitable for use in particle accelerators, MRI gradient amplifiers, stable power supplies, precision drives, battery testing, power measurement, and current calibration.
Specifications: The nominal primary AC current is 283 Arms, and the DC current ranges from -400 to 400 A. The measuring range extends to ±440 A. The primary/secondary ratio is 25.000 V/kA. The device operates within a temperature range of -40°C to 85°C and requires a power supply voltage of ±14.25 to ±15.75 V.
Electrical Specifications: At 23°C and a supply voltage of ±15V, the device has a bandwidth of 300 kHz and a response time of 1 µs. The amplitude error varies with frequency, and the phase shift is minimal across the specified frequency range.
Isolation Specifications: The device has a clearance of 9 mm and a creepage distance of 10 mm. It can withstand an impulse voltage of 10.4 kV and has a rated rms isolation voltage of 300 V for reinforced isolation.
Advanced Sensor Protection Circuits (ASPC): These circuits protect the transducer from fault conditions, allowing DC and AC primary current up to 100% of nominal value without damage. The sensor core may become magnetized, causing a minor output offset change.
Accessories: Available accessories include a 4-channel power supply unit and various lengths of transducer cables.
Mounting Instructions: The device can be mounted using base plate or back side panel methods, with specific screw sizes and torque requirements.
See more

Catalog excerpts

DS400UB-10V-1

DS400UB-10V Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 440A ✓ RoHS 2011/65/E U Features Linearity error maximum 27 ppm 10V BNC output connection Fluxgate, closed loop compensated technology with fixed excitation frequency and second harmonic zero flux detection for best in class accuracy and stability Industry standard DSUB 9 pin connection Green diode for normal operation indication Full aluminum body for superior EMI shielding and extended operating temperature range Large aperture ^27.6mm for cables and bus bars Applications: MPS for particles accelerators Gradient amplifiers for MRI devices Stable power supplies Precision drives Batteries testing and evaluation systems Power measurement and power analysis Current calibration purposes Specification highlights All ppm (or %) values refer to nominal current Precision - Innovation www.danisense.com

 Open the catalog to page 1
DS400UB-10V-2

dani/enseElectrical specifications at Ta=23°C, supply voltage = ± 15V unless otherwise stated Parameter Precision - Innovation www.danisense.com

 Open the catalog to page 2
DS400UB-10V-3

Frequency and ambient temperature derating (Fig. 2) Primary Current (Hz) Max current (Arms) 85 deg Precision – Innovation www.danisense.com

 Open the catalog to page 3
DS400UB-10V-4

dani/ense Isolation specifications Precision - Innovation www.danisense.com

 Open the catalog to page 4
DS400UB-10V-5

dani/ense Advanced Sensor Protection Circuits "ASPC" Developed to protect the current transducer from typical fault conditions: • Unit is un-powered and secondary circuit is open or closed • Unit is powered and secondary circuit is open or interrupted Both DC and AC primary current up to 100% of nominal value can be applied to the current transducers in the above situations without damage to the electronics. Please notice that the sensor core can be magnetized in all above cases, leading to a small change in output offset current (less than 10ppm) Status pins When transducer is operating in...

 Open the catalog to page 5
DS400UB-10V-6

dani/ense (general tolerance 0.3mm unless otherwise stat- When sensor is operating in normal condition the status pins are shorted. Status pin properties. - Forward direction pin 8 to pin 3 - Maximum forward current 10mA - Maximum forward voltage 60V - Maximum reverse voltage 5V Positive current direction Is identified by an arrow on the transducer body Mounting instructions • Base plate mounting 2 holes ^6.5 2 x M5 steel screws / 6N.m 3 holes ^4.0 x 6H 3 x M4 steel screw / 4N.m Precision - Innovation www.danisense.com Back side panel mounting

 Open the catalog to page 6

All Danisense catalogs and technical brochures

  1. DS600ID

    9  Pages

  2. DS400ID

    9  Pages

  3. DS300ID

    9  Pages

  4. DS200ID

    9  Pages

  5. DT200ID

    8  Pages

  6. DT100ID

    8  Pages

  7. DT50ID

    8  Pages

  8. DQ640ID-B

    7  Pages

  9. DQ600ID-P1300

    7  Pages

  10. DQ600ID

    9  Pages

  11. DQ500ID

    7  Pages

  12. DL2000ID

    10  Pages

  13. RCM Smart

    10  Pages

  14. RCM Standard

    9  Pages

  15. DSSIU-1

    5  Pages

  16. DSUB2-20

    1  Page

  17. DSSIU-6-1U-V

    8  Pages

  18. DSSIU-4-1U

    6  Pages

  19. DS50ID

    9  Pages

  20. DL2000UB-10V

    9  Pages

  21. DL2000UB-1V

    9  Pages

  22. DS300UB-1V

    8  Pages

  23. DS300UB-10V

    8  Pages

  24. DN1000ID

    9  Pages

  25. DW500UB-2V

    9  Pages

  26. DM1200ID

    8  Pages

  27. DSSIU-6-1U

    7  Pages

  28. DR10000IM

    9  Pages

  29. DR5000IM

    9  Pages

  30. DP50IP-B

    4  Pages

  31. VOM1333-10

    1  Page

  32. DC200IF

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.