DS200ID

DS200ID

DS200ID

Product catalog summary
Overview: The DS200ID is a high precision fluxgate AC/DC current transducer designed for galvanically isolated measurement up to 370 A. It features a 500:1 primary/secondary current ratio, a 27.6 mm aperture, and a total accuracy of 16 ppm.
Specifications: The device operates with a nominal primary AC current of 200 Arms and a DC current range of -300 to 300 A. It supports a measuring range of -370 to 370 A and can handle a peak overload capacity of 1500 A for a single pulse of 100ms. The transducer offers a bandwidth of 1 MHz and a response time of 1 µs to 90% of step current.
Accuracy and Error: The linearity error is less than 1 ppm, with an offset current of 15 ppm. The total accuracy varies with frequency, with detailed specifications provided for frequencies ranging from <10 Hz to <1000 kHz.
Isolation and Safety: The DS200ID complies with IEC 61010-1 standards, offering reinforced insulation for high voltage applications. It is designed for indoor use, with an operating temperature range of -40 to 85°C and a relative humidity tolerance of 20-80% non-condensing.
Applications: Suitable for electric vehicle test benches, power measurement and analysis, particle accelerators, MRI devices, battery testing, and precision current sensing.
Installation and Use: The device should be powered by a DSSIU-4-1U or DSSIU-6-1U power supply. It includes advanced sensor protection circuits to prevent damage under fault conditions. Proper connection and polarity must be ensured to avoid damage.
Environmental and Mechanical Characteristics: The transducer is rated for use at altitudes up to 2000 m and has an ingress protection rating of IP20. It weighs 0.6 kg and connects via a D-sub-9 connector.
Compliance: The DS200ID is RoHS compliant and adheres to directives 2014/30/EU and 2014/35/EU, with manufacturing in accordance with EN 63000:2018.
See more

Catalog excerpts

DS200ID-1

• Current output through D-sub-9 connector • Power measurement and power analysis • Particle accelerators • MRI devices and medical scanners • Battery testing and evaluation systems • Current calibration purposes • Stable power supplies • Precision current sensing High precision DC current transducer (DCCT) measuring up to 370 A currents and continuously measuring 300 A currents with a linearity error less than 1 ppm. Based on the ultra stable Danisense closed loop flux gate technology, the DS200ID has very low offset and ultra low drift. It provides high resolution for precise monitoring, reliable and consistent performance, and a rugged design for durability. All information subject to change without notice www.danisense.com

 Open the catalog to page 1
DS200ID-2

1 ppm nominal = 0.6 nA secondary current. 2023-12-15 All information subject to change without notice www.danisense.com

 Open the catalog to page 2
DS200ID-3

Linearity error Linearity error is defined as the deviation from a straight line. The straight line is a linear regression trend line based on the least squares method of the measurement points from 0 to positive max current and another trendline is calculated from 0 to negative max current. The difference between each measured point and the linear trend line is the linearity error. The linearity error eL can be expressed as (1), where Ireading is the measurement result and Ifitted is the regression value. Reading is the actual value measured at a given time. Full scale is the rated nominal value...

 Open the catalog to page 3
DS200ID-4

Primary DC and peak current (A) Figure 2: Maximum measurement resistor RM vs. ambient temperatures Primary current (Arms) Figure 3: Maximum continuous primary current vs. frequency Figure 4: Frequency characteristics All information subject to change without notice

 Open the catalog to page 4
DS200ID-5

A When using REINFORCED insulated wire, all wiring must be insulated for the highest voltage used. When using BASIC insulated or uninsulated wire, follow the specified voltages in the table below: All information subject to change without notice www.danisense.com

 Open the catalog to page 5
DS200ID-6

External devices: External devices connected to current transducers must comply with the standards IEC61010-1 and IEC62368-1 and be energy-limited circuitry The transducer should only be cleaned with a damp cloth. No detergent or chemicals should be used. When multiple primary turns are used or high primary currents are applied the temperature around the transducer will increase, please monitor to ensure that the maximum ratings are not exceeded. It is recommended to have minimum 1 November 2012 mm2 Dato: per15.ampere in the primary bus bar. Intended use The DS200ID is designed to measure current...

 Open the catalog to page 6
DS200ID-7

Positive current direction Positive current direc Figure 5: Dimensions of sensor head. Tolerance is 0.3 mm Out+ Base plate: Back side: Positive current direction Figure 6: External measurement resistor connection, see Fig. 2 Is identified by an arrow on the back side isolation plastic insert. Figure 7: D-sub-9 connection pinout Measurement output negative terminal Status signal negative terminal 0 V connection for supply voltage Negative supply voltage Measurement output positive terminal Status signal positive terminal Positive supply voltage All information subject to change without notice...

 Open the catalog to page 7
DS200ID-8

DS200ID Status signal and LED When the sensor is operating in normal condition the status pins (Status+ and Status-) are shorted by an optocoupler and the green status LED is ON, see Fig. 8. When a fault is detected, or the power Status- is off, the status pins are opened and the green status LED is OFF. Status signal optocoupler ratings found below: Figure 8: Status signal optocoupler Dato: 15. November 2012 Forward direction: Maximum forward current: Maximum forward voltage: Maximum reverse voltage: All information subject to change without notice

 Open the catalog to page 8
DS200ID-9

Declaration of Conformity Danisense A/S Malervej 10 DK-2630 Taastrup Dato: 15. November 2012 Declares that under our sole responsibility that this product is in conformity with the provisions of the following EC Directives, including all amendments, and with national legislation implementing these directives: Directive 2014/30/EU Directive 2014/35/EU And that the following harmonized standards have been applied EEN 61010-1 (Third Edition):2010, EN 61010-1:2010/A1:2019 EN 61010-2-030:2021/A11:2021 EN 61326-1:2013 All DANISENSE products are manufactured in accordance with RoHS directive 2011/65/EU....

 Open the catalog to page 9

All Danisense catalogs and technical brochures

  1. DS600ID

    9  Pages

  2. DS400ID

    9  Pages

  3. DS300ID

    9  Pages

  4. DT200ID

    8  Pages

  5. DT100ID

    8  Pages

  6. DT50ID

    8  Pages

  7. DQ640ID-B

    7  Pages

  8. DQ600ID-P1300

    7  Pages

  9. DQ600ID

    9  Pages

  10. DQ500ID

    7  Pages

  11. DL2000ID

    10  Pages

  12. RCM Smart

    10  Pages

  13. RCM Standard

    9  Pages

  14. DSSIU-1

    5  Pages

  15. DSUB2-20

    1  Page

  16. DSSIU-6-1U-V

    8  Pages

  17. DSSIU-4-1U

    6  Pages

  18. DS50ID

    9  Pages

  19. DL2000UB-10V

    9  Pages

  20. DL2000UB-1V

    9  Pages

  21. DS300UB-1V

    8  Pages

  22. DS300UB-10V

    8  Pages

  23. DN1000ID

    9  Pages

  24. DW500UB-2V

    9  Pages

  25. DM1200ID

    8  Pages

  26. DSSIU-6-1U

    7  Pages

  27. DR10000IM

    9  Pages

  28. DR5000IM

    9  Pages

  29. DP50IP-B

    4  Pages

  30. VOM1333-10

    1  Page

  31. DS400UB-10V

    6  Pages

  32. DC200IF

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.