Catalog excerpts
DP50IP-B Ultra-stable, high precision (ppm class) fluxgate technology DP Series current transducer for isolated DC and AC current measurement on PCB up to 72A Linearity error maximum 10 ppm Measurement resistor up to 100Ω at full scale Stable power supplies Fluxgate, closed loop compensated technology with fixed excitation frequency and second harmonic zero flux detection for best in class accuracy and stability Precision drives Batteries testing and evaluation systems Power measurement and power analysis PCB mount Height 32mm - Suitable for 1U power supplies Programmable for 12.5A, 25A, or 50A via PCB layout 250g weight and compact size - ideal for PCBmounted applications with space constraints Specification highlights Ambient operating temperature range Offset current (including earth field) Power supply voltages Linearity error Bandwidth Transducer programming options Ratio Nominal primary AC current Nominal primary DC current All ppm (or %) values refer to nominal current Precision – Innovation www.danis
Open the catalog to page 1Measuring resistance Linearity error Offset current (including earth field) DC-10Hz Overall accuracy @25°C (= ƐL + IOE ) Offset temperature coefficient Amplitude error Phase shift 1kHz-300kHz Response time to a step current IPN Noise dV/dt influence Comment ppm refers to nominal current ppm refers to nominal current µA refers to secondary current ppm refers to nominal DC current ppm refers to nominal current µA refers to secondary current % refers to nominal current di/dt = 100A/µs Measured on secondary current Measured on secondary current Positive current consumption Negative current...
Open the catalog to page 2DP50IP-B Isolation specifications Parameter Creepage distance Rms voltage for AC isolation test, 50/60 Hz, 1 min - Between primary and (secondary and shield) Impulse withstand voltage (1.2/50µs) Rated rms isolation voltage reinforced isolation, overvoltage category II, Pollution degree 2 according to IEC61010-1 Absolute maximum ratings Parameter Power supply Programmed nominal DC. Maximum 100ms Environmental and mechanical characteristics Parameter Polution Degree Ambient operating temperature range Storage temperature range Relative humidity Precision – Innovation www.danisense.
Open the catalog to page 3(general tolerance 0.2mm unless otherwise stated) Pin 16 Precision – Innovation www.danisense.com
Open the catalog to page 4All Danisense catalogs and technical brochures
-
DW500UB-2V
9 Pages
-
DN1000ID
8 Pages
-
DM1200ID-CD3000
6 Pages
-
DM1200ID
6 Pages
-
DS300UB-10V
7 Pages
-
DS300UB-1V
7 Pages
-
DL2000UB-1V
6 Pages
-
DL2000UB-10V
6 Pages
-
VOM1333-10
1 Pages
-
DSSIU-6-1U
6 Pages
-
DSSIU-6-1U-V
7 Pages
-
DSSIU-4-1U
4 Pages
-
DS400UB-10V
6 Pages
-
DS200ID-CD1000
6 Pages
-
DS50ID
6 Pages
-
DC200IF
4 Pages