• Electric vehicle (EV) test bench • Power measurement and power analysis • Particles accelerators • MRI devices and medical scanners • Battery testing and evaluation systems • Current calibration purposes • Precision current sensing Features • 1000 A rms nominal current • 1500 primary/secondary current ratio • Current output High precision DC current transducer (DCCT) measuring up to 1500 A currents and continuously measuring 1000 A currents with a linearity error less than 1 ppm. With a large aperture and removable isolation insert allowing wide cable terminals, the DN1000ID has an overrange capability of 1200 A rms up to 30 minutes. Based on the ultra stable Danisense closed loop flux gate technology, the DN1000ID has very low offset and ultra low drift. Noise is best in class with sub-ppm rms noise in the frequency range up to 10 kHz. It provides high resolution for precise monitoring, reliable and consistent performance, and a compact and rugged design for easy installation and durability. All information subject to change without notice
Open the catalog to page 12023-12-15 All information subject to change without notice www.danisense.com
Open the catalog to page 2Linearity error Linearity error is defined as the deviation from a straight line. The straight line is a linear regression trend line based on the least squares method of the measurement points from 0 to positive max current and another trendline is calculated from 0 to negative max current. The difference between each measured point and the linear trend line is the linearity error. The linearity error eL can be expressed as (1), where Ireading is the measurement result and Ifitted is the regression value. Reading is the actual value measured at a given time. Full scale is the rated nominal value...
Open the catalog to page 3Primary AC current (Arms) Figure 3: Maximum measurement resistor RM vs. ambient Primary current (Arms) Figure 2: Maximum measurement resistor RM vs. ambient Figure 4: Maximum continuous primary current vs. frequency Gain Phase Figure 5: Frequency characteristics All information subject to change without notice
Open the catalog to page 4A When using REINFORCED insulated wire, all wiring must be insulated for the highest voltage used. When using BASIC insulated or uninsulated wire, follow the specified voltages in the table below: Random vibration test: All information subject to change without notice www.danisense.com
Open the catalog to page 5External devices: External devices connected to current transducers must comply with the standards IEC61010-1 and IEC62368-1 and be energy-limited circuitry The transducer should only be cleaned with a damp cloth. No detergent or chemicals should be used. When multiple primary turns are used or high primary currents are applied the temperature around the transducer will increase. Please monitor to ensure that the maximum ratings are not exceeded. It is recommended to have minimum 1 November 2012 mm2 Dato: per15.ampere in the primary bus bar. Removable isolation plastic insert If the isolation...
Open the catalog to page 6Do not disassemble the unit. If the green status LED is not operating with all cables connected and the system powered up, disconnect power and contact Danisense for further instruction. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. All information subject to change without notice
Open the catalog to page 7NOTICE OF PROPRIETARY RIGHTS THIS DOCUMENT CONTAINS PROPRIET NOT BE REPRODUCED OR TRANSFERR CLOSED TO OTHERS OR USED FOR MA ANYOTHER PURPOSE WITHOUT PRIOR OTHERWISE STATED THE BELOW APPLIES Figure 7: DSUB-9 connection pinout Figure 8: Status signal optocoupler Positive current direc DRAWING NUMBER PART/ASSEMBLY NUMBER Figure 9: ExternalUNLESS measurement connection, see1:1 OTHERWISE STATED THE BELOW resistor APPLIES Figure 6: Dimensions of transducer. 0.3 mm Tolerance Base plate mounting: Back plate mounting: Fastening torque: BREAK CORNERS Positive current direction DESCRIPTION INSPECTIONS TOLERANCES...
Open the catalog to page 8Declaration of Conformity Danisense A/S Malervej 10 DK-2630 Taastrup Dato: 15. November 2012 Declares that under our sole responsibility that this product is in conformity with the provisions of the following EC Directives, including all amendments, and with national legislation implementing these directives: Directive 2014/30/EU Directive 2014/35/EU And that the following harmonized standards have been applied EEN 61010-1 (Third Edition):2010, EN 61010-1:2010/A1:2019 EN 61010-2-030:2021/A11:2021 EN 61326-1:2013 All DANISENSE products are manufactured in accordance with RoHS directive 2011/65/EU....
Open the catalog to page 99 Pages
9 Pages
9 Pages
9 Pages
8 Pages
8 Pages
8 Pages
7 Pages
7 Pages
9 Pages
7 Pages
10 Pages
10 Pages
9 Pages
5 Pages
1 Page
8 Pages
6 Pages
9 Pages
9 Pages
9 Pages
8 Pages
8 Pages
7 Pages
9 Pages
8 Pages
7 Pages
9 Pages
9 Pages
9 Pages
24 Pages
4 Pages
1 Page
6 Pages
6 Pages
4 Pages