Fact Sheet VLT® Soft Starter MCD 600 delivers superior performance for fixed-speed applications The VLT® Soft Starter MCD 600 combines the latest in advanced controls and protections with an increased level of intelligence for superior performance in fixed-speed applications. The MCD 600 is more flexible than ever to install, thanks to a wide variety of Ethernet and serial-based communication option cards, application-dedicated smart cards and support for eight languages. The integrated bypass ensures both extremely high efficiency and harmonicfree operation at full speed, reducing energy consumed and required cooling capacity. Ease of use is also greatly increased with new capabilites, such as the pump-clean function, PowerThrough operation, and calendar or run time-based scheduling. Furthermore, enhanced protection ensures more uptime. Mains voltage range x 200-525 VAC (T5) 3 x 380-690 VAC (T7) 3 Current range and enclosure / IP20 : 20 - 129 A FLC S1 / IP00: 144 - 579 A FLC S2 / IP00: 654 - 1250 A FLC S3 Bypass configuration Select the best configuration for your application: S2, S3 : Built in bypass contactor S1, S3 : No bypass S2, S3 : External bypass External bypass increases FLC performance by up to 30% Intuitive application setup Extended simulation mode with full simulation of start behaivor Save commissioning time. Test your soft starter without connecting mains supply or motor. Easy to set up a timer. No need to install external controller or components. More uptime and longer pump life. Run the MCD 600 in both forward and reverse directions. MCD 600 will maintain full control over starting current and protection. To use this function, install a reversing contactor in the application. More uptime - bypasses damaged components to keep your motor running. Asset protection - keeps the pump or fan running for as long as possible in an emergency. Built-in timers and schedulers Pump Clean (Deragging) function Reverse control function Power Through function bypass delivers all-round cost savings Current (% motor full load current) Emergency mode Rotor speed (% full speed) Three Adaptive Acceleration Control (AAC) start profiles; early, constant and late acceleration Constant current/current ramp – here shown with kickstart
Open the catalog to page 1Advanced start, stop and protection features Auto start/stop clock Compact size injection braking DC 4-line graphical display Multiple programming setup menus AAC Adaptive Acceleration Emergency mode Power Through Simulation mode Available options Fieldbus communication modules: – EtherNet/IP – PROFINET – Modbus TCP – PROFIBUS – DeviceNet – Modbus RTU Remote LCP Option Application card – Smart Pump PC software: – WinStart – VLT® Motion Control Tool MCT 10 VLT® Control Panel LCP 601 Remote mountable option kit – IP65 enclosure class – 3 m cable included Features: – Graphical, multi-line display...
Open the catalog to page 2122 Pages
32 Pages
4 Pages
90 Pages
122 Pages
40 Pages
2 Pages
8 Pages
92 Pages
2 Pages
2 Pages
2 Pages
2 Pages
36 Pages
2 Pages
2 Pages
2 Pages
40 Pages
16 Pages
8 Pages
12 Pages
20 Pages
34 Pages
60 Pages
8 Pages
40 Pages
16 Pages
2 Pages
8 Pages
2 Pages
2 Pages
8 Pages
8 Pages
5 Pages
16 Pages
20 Pages