Overview: The document provides detailed specifications and features of IP 66/Type 4x enclosed VLT® frequency converters, which are designed for harsh environments and cover a power range from 0.25 to 90 kW. These drives are suitable for installation in wash-down areas, outdoor wastewater plants, and rooftop air handling units.
Specifications:
  • Power Range: 3 x 200 – 240 V: 0.25 – 45 kW; 3 x 380 – 600 V: 0.37 – 90 kW with normal overload; 3 x 380 – 600 V: 0.37 – 75 kW with high overload.
  • Mains Supply: Voltage 200-240 V ±10%, 380-500 V ±10%, 525-600 V ±10%; Frequency 50/60 Hz.
  • Output Data: Voltage 0–100% of supply; Unlimited switching on output; Ramp times 1–3600 sec.
  • Digital Inputs: 6 programmable inputs, PNP or NPN logic, 0–24 VDC.
  • Analogue Inputs: 2 inputs, voltage or current modes, scalable levels.
  • Pulse Inputs: 2 programmable inputs, 0–24 VDC, accuracy 0.1–110 kHz.
  • Analogue Output: 1 programmable output, 0/4–20 mA.
  • Relay Outputs: 2 programmable outputs (240 VAC, 2 A and 400VAC, 2 A).
  • Fieldbus Communication: Supports multiple protocols including Modbus, BACnet, and Ethernet.
Features and Benefits:
  • All cast aluminium parts are powder coated with epoxy for corrosion resistance.
  • Stainless steel screws reduce maintenance needs.
  • Fan designed to withstand corrosion ensures reliable operation.
  • Unique cooling concept allows operation in harsh environments without ambient air flow over electronics.
  • Max ambient temperature of 50˚C without derating, eliminating the need for external cooling.
  • Watertight USB plug for easy setup without opening the drive.
Installation and Usage:
  • Drives can be installed directly at processing equipment without protective covers.
  • Stainless steel back plate available for open mounting to guide air from the fan.
  • For outdoor installations, drives must be protected from direct sun, snow, and ice exposure.
Approvals and Compliance: The drives comply with IEC 60721-3-3 level 3C3 for protection against corrosive gases and have approvals from Norske Veritas, CCl.
See more

Catalog excerpts

VLT® drives up to 90 kW-2

Stainless steel back plate For open mounting - like on a frame - a stainless steel back plate is available to guide the air from the fan through A watertight USB plug is available for mounting in a gland hole in the bottom of the drive. With this plug it is possible to commission the drive via theVLT® Set-up Software MCT 10 without opening the drive ■ Harmonics calculations tool Free download from The drive must be installed under a suitable cover to protect from direct Analogue reference inputs Analogue inputs Voltage level Current level Pulse inputs Programmable pulse inputs 2 Voltage level...

 Open the catalog to page 2

All Danfoss VLT Drives catalogs and technical brochures

  1. VACON® 100

    32  Pages

  2. TP5001 Range

    92  Pages

  3. Danfoss Drives

    12  Pages

  4. VLT®

    20  Pages

  5. VLT 2800

    34  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.