VLT® DriveMotor: FCM 106 / FCP 106
12Pages

{{requestButtons}}

Catalog excerpts

VLT® DriveMotor: FCM 106 / FCP 106 - 1

TOMORROW LJfXftll/vo Selection guide omplies with both

Open the catalog to page 1
VLT® DriveMotor: FCM 106 / FCP 106 - 2

One drive. Two solutions. Full flexibility. Select the drive component as a stand-alone unit or factory mounted to a high efficiency permanent magnet (PM) or induction motor (IM), and enjoy the benefits of Danfoss’ new VLT® DriveMotor. With integrated fan, pump and basic industry features, and VVC+ motor control, the VLT® DriveMotor is a space saving, efficient alternative to drive solutions in the 0.55-7.5 kW range. Motor mounted for IE4 efficiency Available as a motor-mounted drive solution the VLT® DriveMotor FCM 106 can be delivered factory fitted to either an IE 4 rated PM or IE 2...

Open the catalog to page 2
VLT® DriveMotor: FCM 106 / FCP 106 - 3

Maximize system efficiency with EC+ Optimize PM motor performance To make it possible for users to benefit from the high motor efficiency on the same level or above EC technology, Danfoss has refined its VVC+ control algorithm and optimized it for permanent magnet motors. After entering the relevant motor data, the drive automatically optimizes the performance of the application. Easy maintenance Component replacement as a result of wear and tear is not always possible without installing a complete new, integrated system. The EC+ concept answers this by making service and maintenance...

Open the catalog to page 3
VLT® DriveMotor: FCM 106 / FCP 106 - 4

Installation friendly The VLT® DriveMotor FCM 106 is a complete drive and motor solution. Its compact design reduces both installation costs and complexity significantly. By eliminating the need for cabinets and long motor cables, costs are reduced further. Flexible installation Integrated cooling and an individually adjustable motor adapter plate makes installation very simple. The VLT® DriveMotor FCM 106 has an IP 54 protection rating and is UL approved UL type 3R for outdoor installation. Attach the frequency converter to any motor For those who prefer to choose their own motor, VLT®...

Open the catalog to page 4
VLT® DriveMotor: FCM 106 / FCP 106 - 5

Constant Torque at 160% overload in industrial applications, e.g. conveyors reduces THiD to less than 46%. This results in extended drive lifetime and minimized harmonic load of mains. Industrial features Built-in Smart Logic Controller The Smart Logic Controller is a simple but clever way to keep your drive, motor and application working together without a PLC. The controller monitors a specified event. When an event occurs, the controller triggers a specified act and starts monitoring the next event, continuing for up to 20 steps before returning to step one. Motor thermistor If increased...

Open the catalog to page 5
VLT® DriveMotor: FCM 106 / FCP 106 - 6

Fan features VLT® DriveMotor FCP 106 and VLT® DriveMotor FCM 106 are equipped with basic air handling unit functions to ensure safety, equipment reliability and low noise operation. Belt monitoring Based on the speed/current the drive can detect situations where the motor has lost contact with the fan and raise an alarm. Flying start This protective feature prevents violent starts and wear and tear on the equipment. By detecting the speed and direction of a freely spinning fan the drive can catch it at the correct frequency. Resonance monitoring Using only a few keystrokes on the local...

Open the catalog to page 6
VLT® DriveMotor: FCM 106 / FCP 106 - 7

VLT® DriveMotor FCM 106 Fire override mode This setting prevents the drive from stopping to protect itself and ensures that vital fan operation is maintained for as long as possible, regardless of control signals, warnings or alarms. Stairwell pressurization In the event of a fire, the FCM/FCP 106 can maintain a higher level of air pressure in stairwells than in other parts of the building. This helps ensure that fire escapes remain free of smoke. at full speed without creating the desired pressure. Check valve ramp* This feature protects the check valve and helps prevent water hammering....

Open the catalog to page 7
VLT® DriveMotor: FCM 106 / FCP 106 - 8

Connection examples 3 Phase power input Placed in motor plug The numbers represent the terminals on the drive. ON=Terminated OFF=Open The diagram shows the terminals of the VLT® DriveMotor FCM 106 and VLT® DriveMotor FCP 106. Users can set the mode of the analogue inputs 53 and 54. The FCM/FCP 106 has a RS485 interface as standard. The RS485 terminations are integrated in the drive (S801). The drive can be equipped with a PROFIBUS** option if necessary. To switch from NPN to PNP logic for the digital signals, use parameter Group 5-*. ** Release 2015

Open the catalog to page 8
VLT® DriveMotor: FCM 106 / FCP 106 - 9

Power and currents For VLT® DriveMotor FCP 106 Mains Supply 3 x 380 – 480 VAC IP 54 Enclosure Typical Shaft Output [kW] Typical Shaft Output [HP] at 460 V Output current Continuous (3 x 380-440 V) [A] Intermittent (3 x 380-440 V) [A] Continuous (3 x 441-480 V) [A] Intermittent (3 x 441-480 V) [A] Max. cable cross-section in terminals (mains, motor) [mm2/ AWG] Max. input current Continuous (3 x 380-440 V) [A] Intermittent (3 x 380-440 V) [A] Continuous (3 x 441-480 V) [A] Intermittent (3 x 441-480 V) [A] Typical Shaft Output [kW] Typical Shaft Output [HP] at 460 V Output current Continuous...

Open the catalog to page 9
VLT® DriveMotor: FCM 106 / FCP 106 - 10

Ordering type code VLT® DriveMotor FCP 106 VLT® DriveMotor FCM 106 Position Fixed Fixed Variants Product group VLT® DriveMotor FCM 106 VLT® DriveMotor FCP 106 Frequency converter series VLT® DriveMotor Power size 0.55 kW / 0.75 HP 0.75 kW / 1.0 HP 1.1 kW / 1.5 HP 1.5 kW / 2.0 HP 2.2 kW / 3.0 HP 3.0 kW / 4.0 HP 4.0 kW / 5.0 HP 5.5 kW / 7.5 HP 7.5 kW / 10 HP Mains voltage Three phase 380 – 480 V Enclosure IP 54 – FCM 106 IP 54 – FCP 106 RFI filter Integrated RFI filter C1 Fan Cooling fan Software Standard software PROFIBUS DP V1 and Memory module* Not assigned Not assigned Motor range...

Open the catalog to page 10
VLT® DriveMotor: FCM 106 / FCP 106 - 11

Specifications Mains supply (L1, L2, L3) Supply voltage Supply frequency True Power Factor (λ) Displacement Power Factor (cos ф) Switching on input supply Output data (U, V, W) Output voltage Output frequency n VLT® Control Panel LCP 31 (LCP only) Ordering number: 132B0200 380 – 480 V ±10% 50/60 Hz ≥ 0.9 nominal at rated load (>0.98) Max. 2 times/min. n VLT® Control Panel LCP 31 Mounting Kit 3 m cable, panel mounting bracket, gasket and fastners Ordering number: 134B0557 0 – 100% of supply 0– 200 Hz (asynchronous motor) 0 – 390 Hz (PM motor) Unlimited 0.05 – 3600 sec. Switching on output...

Open the catalog to page 11

All Danfoss VLT Drives catalogs and technical brochures

  1. VACON® 100

    32 Pages

  2. TP5001 Range

    92 Pages

  3. Danfoss Drives

    12 Pages

  4. VLT®

    20 Pages

  5. VLT 2800

    34 Pages